Cargando…

Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage

BACKGROUND AND OBJECTIVES: EUS-guided gallbladder drainage (EUS-GBD) has become one of the recommended treatments for patients with high-risk acute cholecystitis. However, the gallbladder reportedly collapsed due to bile leakage, which was a disadvantage that affects the surgical success rate. Diffe...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kai, Ge, Nan, Guo, Jintao, Wang, Sheng, Sun, Siyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9688136/
https://www.ncbi.nlm.nih.gov/pubmed/36255025
http://dx.doi.org/10.4103/EUS-D-21-00240
_version_ 1784836191077531648
author Zhang, Kai
Ge, Nan
Guo, Jintao
Wang, Sheng
Sun, Siyu
author_facet Zhang, Kai
Ge, Nan
Guo, Jintao
Wang, Sheng
Sun, Siyu
author_sort Zhang, Kai
collection PubMed
description BACKGROUND AND OBJECTIVES: EUS-guided gallbladder drainage (EUS-GBD) has become one of the recommended treatments for patients with high-risk acute cholecystitis. However, the gallbladder reportedly collapsed due to bile leakage, which was a disadvantage that affects the surgical success rate. Different electrocautery-enhanced delivery of the lumen-apposing metal stents (ECE-LAMSs) using suitable power levels in electrosurgical workstations can increase the surgical success rate and reduce trauma. Therefore, we proposed the use of the ECE-LAMSs and electrosurgical workstations for the first time through ex vivo experiments to adjust the different power levels and select the most suitable electrosurgical power for each ECE-LAMS type. METHODS: We compared three types of ECE-LAMS (9Fr, 10.5Fr, and 10.8Fr) with three types of electrosurgical workstations during EUS-GBD. GBD was simulated ex vivo under the guidance of an ultrasound endoscope. We performed various power tests to elucidate the ideal electric power for different ECE-LAMS combined with the different types of electrosurgical workstations. RESULTS: For the 10.8Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 200 W, 200 W, and 250W. For the 10.5Fr and 9Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 150 W, 200 W, and 200 W. CONCLUSION: During the operations, due to low-power levels in the electrosurgical workstations increased the number of cuts, the EUS images were obviously unclear, which affected the success rates of the operations. We suggested different power levels for the different types of LAMS and their matching electrosurgical workstations, which can increase the surgical success rates and reduce surgical injuries.
format Online
Article
Text
id pubmed-9688136
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-96881362022-11-25 Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage Zhang, Kai Ge, Nan Guo, Jintao Wang, Sheng Sun, Siyu Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVES: EUS-guided gallbladder drainage (EUS-GBD) has become one of the recommended treatments for patients with high-risk acute cholecystitis. However, the gallbladder reportedly collapsed due to bile leakage, which was a disadvantage that affects the surgical success rate. Different electrocautery-enhanced delivery of the lumen-apposing metal stents (ECE-LAMSs) using suitable power levels in electrosurgical workstations can increase the surgical success rate and reduce trauma. Therefore, we proposed the use of the ECE-LAMSs and electrosurgical workstations for the first time through ex vivo experiments to adjust the different power levels and select the most suitable electrosurgical power for each ECE-LAMS type. METHODS: We compared three types of ECE-LAMS (9Fr, 10.5Fr, and 10.8Fr) with three types of electrosurgical workstations during EUS-GBD. GBD was simulated ex vivo under the guidance of an ultrasound endoscope. We performed various power tests to elucidate the ideal electric power for different ECE-LAMS combined with the different types of electrosurgical workstations. RESULTS: For the 10.8Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 200 W, 200 W, and 250W. For the 10.5Fr and 9Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 150 W, 200 W, and 200 W. CONCLUSION: During the operations, due to low-power levels in the electrosurgical workstations increased the number of cuts, the EUS images were obviously unclear, which affected the success rates of the operations. We suggested different power levels for the different types of LAMS and their matching electrosurgical workstations, which can increase the surgical success rates and reduce surgical injuries. Wolters Kluwer - Medknow 2022-06-08 /pmc/articles/PMC9688136/ /pubmed/36255025 http://dx.doi.org/10.4103/EUS-D-21-00240 Text en Copyright: © 2022 SCHOLAR MEDIA PUBLISHING https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Zhang, Kai
Ge, Nan
Guo, Jintao
Wang, Sheng
Sun, Siyu
Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title_full Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title_fullStr Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title_full_unstemmed Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title_short Ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during EUS-guided gallbladder drainage
title_sort ex vivo comparison of electrocautery-enhanced delivery of lumen-apposing metal stents matching electrosurgical workstations during eus-guided gallbladder drainage
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9688136/
https://www.ncbi.nlm.nih.gov/pubmed/36255025
http://dx.doi.org/10.4103/EUS-D-21-00240
work_keys_str_mv AT zhangkai exvivocomparisonofelectrocauteryenhanceddeliveryoflumenapposingmetalstentsmatchingelectrosurgicalworkstationsduringeusguidedgallbladderdrainage
AT genan exvivocomparisonofelectrocauteryenhanceddeliveryoflumenapposingmetalstentsmatchingelectrosurgicalworkstationsduringeusguidedgallbladderdrainage
AT guojintao exvivocomparisonofelectrocauteryenhanceddeliveryoflumenapposingmetalstentsmatchingelectrosurgicalworkstationsduringeusguidedgallbladderdrainage
AT wangsheng exvivocomparisonofelectrocauteryenhanceddeliveryoflumenapposingmetalstentsmatchingelectrosurgicalworkstationsduringeusguidedgallbladderdrainage
AT sunsiyu exvivocomparisonofelectrocauteryenhanceddeliveryoflumenapposingmetalstentsmatchingelectrosurgicalworkstationsduringeusguidedgallbladderdrainage