Cargando…

Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System

The Zero-P spacer was primarily developed aiming to reduce the morbidity associated with the traditional anterior cervical plate. During the past decade, many authors have reported the use of Zero-P spacers for anterior cervical discectomy and fusion (ACDF) of one or two segments. Nevertheless, ther...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Jing, Jin, Weiming, Shi, Yan, Guan, Zhiping, Wen, Jian, Huang, Yongcan, Yu, Binsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9688593/
https://www.ncbi.nlm.nih.gov/pubmed/36421907
http://dx.doi.org/10.3390/brainsci12111583
_version_ 1784836307473661952
author Guo, Jing
Jin, Weiming
Shi, Yan
Guan, Zhiping
Wen, Jian
Huang, Yongcan
Yu, Binsheng
author_facet Guo, Jing
Jin, Weiming
Shi, Yan
Guan, Zhiping
Wen, Jian
Huang, Yongcan
Yu, Binsheng
author_sort Guo, Jing
collection PubMed
description The Zero-P spacer was primarily developed aiming to reduce the morbidity associated with the traditional anterior cervical plate. During the past decade, many authors have reported the use of Zero-P spacers for anterior cervical discectomy and fusion (ACDF) of one or two segments. Nevertheless, there is still a paucity of knowledge on the safety and feasibility of using Zero-P spacers for 3-level fixation. The objective of this study was to investigate the clinical and radiological outcomes, with a focus on the sagittal alignment reconstruction of 3-level ACDF surgery using Zero-P spacers versus those using a traditional plate and cage system. From Sep 2013 to Aug 2016, a total of 44 patients who received 3-level ACDF surgery due to cervical spondylotic myelopathy were recruited. The Zero-P spacer was used in 23 patients (group ZP) and the traditional plate and cage system in 21 (group PC). Clinical outcomes were analyzed by Neck Disability Index (NDI) and Japanese Orthopedic Association (JOA) scores, and dysphagia was evaluated using the Bazaz score. Radiological outcomes, including fusion rate, adjacent segment degeneration (ASD), and especially changes in cervical sagittal alignment, were analyzed. The NDI and JOA scores did not differ significantly between the two groups postoperatively (p > 0.05); however, there was significantly less dysphagia in patients using Zero-P spacers at the 3- and 6-month follow-up (p < 0.05). At the 24-month follow-up, the fusion rate and ASD were similar between the two groups (p > 0.05). Interestingly, patients using Zero-P spacers had a significantly lower postoperative C2-7 Cobb angle and fused segment Cobb angle, compared to those using a traditional plate and cage system (p < 0.05); meanwhile, the fused segment disc wedge was also found to be significantly smaller in patients using Zero-P spacers after surgery (p < 0.05). Moreover, we further divided patients into subgroups according to their cervical lordosis. In patients with a preoperative C2-7 Cobb angle ≤ 10°, significantly less cervical and local lordosis, as well as disc wedge, were seen in group ZP after surgery (p < 0.05), while in others with a preoperative C2-7 Cobb angle > 10°, no significant difference in postoperative changes of the cervical sagittal alignment was seen between group ZP and group PC (p > 0.05). Zero-P spacers used in 3-level ACDF surgery could provide equivalent clinical outcomes and a lower rate of postoperative dysphagia, compared to the traditional plate and cage system. However, our results showed that it was inferior to the cervical plate in terms of sagittal alignment reconstruction for 3-level fixation. We recommend applying Zero-P spacers for 3-level ACDF in patients with good preoperative cervical lordosis (C2-7 Cobb angle > 10°), in order to restore and maintain physiological curvature of the cervical spine postoperatively.
format Online
Article
Text
id pubmed-9688593
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96885932022-11-25 Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System Guo, Jing Jin, Weiming Shi, Yan Guan, Zhiping Wen, Jian Huang, Yongcan Yu, Binsheng Brain Sci Article The Zero-P spacer was primarily developed aiming to reduce the morbidity associated with the traditional anterior cervical plate. During the past decade, many authors have reported the use of Zero-P spacers for anterior cervical discectomy and fusion (ACDF) of one or two segments. Nevertheless, there is still a paucity of knowledge on the safety and feasibility of using Zero-P spacers for 3-level fixation. The objective of this study was to investigate the clinical and radiological outcomes, with a focus on the sagittal alignment reconstruction of 3-level ACDF surgery using Zero-P spacers versus those using a traditional plate and cage system. From Sep 2013 to Aug 2016, a total of 44 patients who received 3-level ACDF surgery due to cervical spondylotic myelopathy were recruited. The Zero-P spacer was used in 23 patients (group ZP) and the traditional plate and cage system in 21 (group PC). Clinical outcomes were analyzed by Neck Disability Index (NDI) and Japanese Orthopedic Association (JOA) scores, and dysphagia was evaluated using the Bazaz score. Radiological outcomes, including fusion rate, adjacent segment degeneration (ASD), and especially changes in cervical sagittal alignment, were analyzed. The NDI and JOA scores did not differ significantly between the two groups postoperatively (p > 0.05); however, there was significantly less dysphagia in patients using Zero-P spacers at the 3- and 6-month follow-up (p < 0.05). At the 24-month follow-up, the fusion rate and ASD were similar between the two groups (p > 0.05). Interestingly, patients using Zero-P spacers had a significantly lower postoperative C2-7 Cobb angle and fused segment Cobb angle, compared to those using a traditional plate and cage system (p < 0.05); meanwhile, the fused segment disc wedge was also found to be significantly smaller in patients using Zero-P spacers after surgery (p < 0.05). Moreover, we further divided patients into subgroups according to their cervical lordosis. In patients with a preoperative C2-7 Cobb angle ≤ 10°, significantly less cervical and local lordosis, as well as disc wedge, were seen in group ZP after surgery (p < 0.05), while in others with a preoperative C2-7 Cobb angle > 10°, no significant difference in postoperative changes of the cervical sagittal alignment was seen between group ZP and group PC (p > 0.05). Zero-P spacers used in 3-level ACDF surgery could provide equivalent clinical outcomes and a lower rate of postoperative dysphagia, compared to the traditional plate and cage system. However, our results showed that it was inferior to the cervical plate in terms of sagittal alignment reconstruction for 3-level fixation. We recommend applying Zero-P spacers for 3-level ACDF in patients with good preoperative cervical lordosis (C2-7 Cobb angle > 10°), in order to restore and maintain physiological curvature of the cervical spine postoperatively. MDPI 2022-11-19 /pmc/articles/PMC9688593/ /pubmed/36421907 http://dx.doi.org/10.3390/brainsci12111583 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guo, Jing
Jin, Weiming
Shi, Yan
Guan, Zhiping
Wen, Jian
Huang, Yongcan
Yu, Binsheng
Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title_full Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title_fullStr Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title_full_unstemmed Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title_short Is the Zero-P Spacer Suitable for 3-Level Anterior Cervical Discectomy and Fusion Surgery in Terms of Sagittal Alignment Reconstruction: A Comparison Study with Traditional Plate and Cage System
title_sort is the zero-p spacer suitable for 3-level anterior cervical discectomy and fusion surgery in terms of sagittal alignment reconstruction: a comparison study with traditional plate and cage system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9688593/
https://www.ncbi.nlm.nih.gov/pubmed/36421907
http://dx.doi.org/10.3390/brainsci12111583
work_keys_str_mv AT guojing isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT jinweiming isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT shiyan isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT guanzhiping isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT wenjian isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT huangyongcan isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem
AT yubinsheng isthezeropspacersuitablefor3levelanteriorcervicaldiscectomyandfusionsurgeryintermsofsagittalalignmentreconstructionacomparisonstudywithtraditionalplateandcagesystem