Cargando…

Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks

The early detection of hepatic fibrosis is of critical importance. Ultrasound backscattered radiofrequency signals from the liver contain abundant information about its microstructure. We proposed a method for characterizing human hepatic fibrosis using one-dimensional convolutional neural networks...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yong, Zeng, Yan, Bin, Guangyu, Ding, Qiying, Wu, Shuicai, Tai, Dar-In, Tsui, Po-Hsiang, Zhou, Zhuhuang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689172/
https://www.ncbi.nlm.nih.gov/pubmed/36428892
http://dx.doi.org/10.3390/diagnostics12112833
_version_ 1784836462980628480
author Huang, Yong
Zeng, Yan
Bin, Guangyu
Ding, Qiying
Wu, Shuicai
Tai, Dar-In
Tsui, Po-Hsiang
Zhou, Zhuhuang
author_facet Huang, Yong
Zeng, Yan
Bin, Guangyu
Ding, Qiying
Wu, Shuicai
Tai, Dar-In
Tsui, Po-Hsiang
Zhou, Zhuhuang
author_sort Huang, Yong
collection PubMed
description The early detection of hepatic fibrosis is of critical importance. Ultrasound backscattered radiofrequency signals from the liver contain abundant information about its microstructure. We proposed a method for characterizing human hepatic fibrosis using one-dimensional convolutional neural networks (CNNs) based on ultrasound backscattered signals. The proposed CNN model was composed of four one-dimensional convolutional layers, four one-dimensional max-pooling layers, and four fully connected layers. Ultrasound radiofrequency signals collected from 230 participants (F0: 23; F1: 46; F2: 51; F3: 49; F4: 61) with a 3-MHz transducer were analyzed. Liver regions of interest (ROIs) that contained most of the liver ultrasound backscattered signals were manually delineated using B-mode images reconstructed from the backscattered signals. ROI signals were normalized and augmented by using a sliding window technique. After data augmentation, the radiofrequency signal segments were divided into training sets, validation sets and test sets at a ratio of 80%:10%:10%. In the test sets, the proposed algorithm produced an area under the receive operating characteristic curve of 0.933 (accuracy: 91.30%; sensitivity: 92.00%; specificity: 90.48%), 0.997 (accuracy: 94.29%; sensitivity: 94.74%; specificity: 93.75%), 0.818 (accuracy: 75.00%; sensitivity: 69.23%; specificity: 81.82%), and 0.934 (accuracy: 91.67%; sensitivity: 88.89%; specificity: 94.44%) for diagnosis liver fibrosis stage ≥F1, ≥F2, ≥F3, and ≥F4, respectively. Experimental results indicated that the proposed deep learning algorithm based on ultrasound backscattered signals yields a satisfying performance when diagnosing hepatic fibrosis stages. The proposed method may be used as a new quantitative ultrasound approach to characterizing hepatic fibrosis.
format Online
Article
Text
id pubmed-9689172
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96891722022-11-25 Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks Huang, Yong Zeng, Yan Bin, Guangyu Ding, Qiying Wu, Shuicai Tai, Dar-In Tsui, Po-Hsiang Zhou, Zhuhuang Diagnostics (Basel) Article The early detection of hepatic fibrosis is of critical importance. Ultrasound backscattered radiofrequency signals from the liver contain abundant information about its microstructure. We proposed a method for characterizing human hepatic fibrosis using one-dimensional convolutional neural networks (CNNs) based on ultrasound backscattered signals. The proposed CNN model was composed of four one-dimensional convolutional layers, four one-dimensional max-pooling layers, and four fully connected layers. Ultrasound radiofrequency signals collected from 230 participants (F0: 23; F1: 46; F2: 51; F3: 49; F4: 61) with a 3-MHz transducer were analyzed. Liver regions of interest (ROIs) that contained most of the liver ultrasound backscattered signals were manually delineated using B-mode images reconstructed from the backscattered signals. ROI signals were normalized and augmented by using a sliding window technique. After data augmentation, the radiofrequency signal segments were divided into training sets, validation sets and test sets at a ratio of 80%:10%:10%. In the test sets, the proposed algorithm produced an area under the receive operating characteristic curve of 0.933 (accuracy: 91.30%; sensitivity: 92.00%; specificity: 90.48%), 0.997 (accuracy: 94.29%; sensitivity: 94.74%; specificity: 93.75%), 0.818 (accuracy: 75.00%; sensitivity: 69.23%; specificity: 81.82%), and 0.934 (accuracy: 91.67%; sensitivity: 88.89%; specificity: 94.44%) for diagnosis liver fibrosis stage ≥F1, ≥F2, ≥F3, and ≥F4, respectively. Experimental results indicated that the proposed deep learning algorithm based on ultrasound backscattered signals yields a satisfying performance when diagnosing hepatic fibrosis stages. The proposed method may be used as a new quantitative ultrasound approach to characterizing hepatic fibrosis. MDPI 2022-11-17 /pmc/articles/PMC9689172/ /pubmed/36428892 http://dx.doi.org/10.3390/diagnostics12112833 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Yong
Zeng, Yan
Bin, Guangyu
Ding, Qiying
Wu, Shuicai
Tai, Dar-In
Tsui, Po-Hsiang
Zhou, Zhuhuang
Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title_full Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title_fullStr Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title_full_unstemmed Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title_short Evaluation of Hepatic Fibrosis Using Ultrasound Backscattered Radiofrequency Signals and One-Dimensional Convolutional Neural Networks
title_sort evaluation of hepatic fibrosis using ultrasound backscattered radiofrequency signals and one-dimensional convolutional neural networks
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689172/
https://www.ncbi.nlm.nih.gov/pubmed/36428892
http://dx.doi.org/10.3390/diagnostics12112833
work_keys_str_mv AT huangyong evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT zengyan evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT binguangyu evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT dingqiying evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT wushuicai evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT taidarin evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT tsuipohsiang evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks
AT zhouzhuhuang evaluationofhepaticfibrosisusingultrasoundbackscatteredradiofrequencysignalsandonedimensionalconvolutionalneuralnetworks