Cargando…

Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)

Porcine epidemic diarrhea virus (PEDV) and porcine circovirus type 2 (PCV2) are both important global pathogenic viruses which have a significant impact on the swine industry. In this study, a duplex loop-mediated isothermal amplification (duplex LAMP) method was developed in combination with latera...

Descripción completa

Detalles Bibliográficos
Autores principales: Areekit, Supatra, Tangjitrungrot, Pongbun, Khuchareontaworn, Sintawee, Rattanathanawan, Kankanit, Jaratsing, Pornpun, Yasawong, Montri, Chansiri, Gaysorn, Viseshakul, Nareerat, Chansiri, Kosum
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689611/
https://www.ncbi.nlm.nih.gov/pubmed/36354680
http://dx.doi.org/10.3390/cimb44110368
_version_ 1784836579007660032
author Areekit, Supatra
Tangjitrungrot, Pongbun
Khuchareontaworn, Sintawee
Rattanathanawan, Kankanit
Jaratsing, Pornpun
Yasawong, Montri
Chansiri, Gaysorn
Viseshakul, Nareerat
Chansiri, Kosum
author_facet Areekit, Supatra
Tangjitrungrot, Pongbun
Khuchareontaworn, Sintawee
Rattanathanawan, Kankanit
Jaratsing, Pornpun
Yasawong, Montri
Chansiri, Gaysorn
Viseshakul, Nareerat
Chansiri, Kosum
author_sort Areekit, Supatra
collection PubMed
description Porcine epidemic diarrhea virus (PEDV) and porcine circovirus type 2 (PCV2) are both important global pathogenic viruses which have a significant impact on the swine industry. In this study, a duplex loop-mediated isothermal amplification (duplex LAMP) method was developed in combination with lateral flow dipstick (LFD) for simultaneous detection of PEDV and PCV2 using specific sets of primers and probes designed based on the conserved regions of a spike gene (KF272920) and an ORF gene (EF493839), respectively. The limit of detection (LOD) values of the duplex LAMP-LFD for the detection of PEDV and PCV2 were 0.1 ng/µL and 0.246 ng/µL, respectively. The LOD of duplex LAMP-LFD was 10-times more sensitive than conventional PCR and RT-PCR-agarose gel-electrophoresis (PCR-AGE and RT-PCR-AGE). No cross-reaction to each other and to other pathogenic viruses that can infect pigs were observed according to analytical specificity tests. The duplex LAMP-LFD method for the simultaneous detection of PEDV and PCV2 co-infection could be completed within approximately 1.5 h, and only a simple heating block was required for isothermal amplification. The preliminary validation using 50 swine clinical samples with positive and negative PEDV and/or PCV2 revealed that the sensitivity, specificity, and accuracy of duplex LAMP-LFD were all 100% in comparison to conventional PCR and RT-PCR. Hence, this study suggests that duplex LAMP-LFD is a promising tool for the early detection and initial screening of PEDV and PCV2, which could be beneficial for prevention, planning, and epidemiological surveys of these diseases.
format Online
Article
Text
id pubmed-9689611
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96896112022-11-25 Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2) Areekit, Supatra Tangjitrungrot, Pongbun Khuchareontaworn, Sintawee Rattanathanawan, Kankanit Jaratsing, Pornpun Yasawong, Montri Chansiri, Gaysorn Viseshakul, Nareerat Chansiri, Kosum Curr Issues Mol Biol Article Porcine epidemic diarrhea virus (PEDV) and porcine circovirus type 2 (PCV2) are both important global pathogenic viruses which have a significant impact on the swine industry. In this study, a duplex loop-mediated isothermal amplification (duplex LAMP) method was developed in combination with lateral flow dipstick (LFD) for simultaneous detection of PEDV and PCV2 using specific sets of primers and probes designed based on the conserved regions of a spike gene (KF272920) and an ORF gene (EF493839), respectively. The limit of detection (LOD) values of the duplex LAMP-LFD for the detection of PEDV and PCV2 were 0.1 ng/µL and 0.246 ng/µL, respectively. The LOD of duplex LAMP-LFD was 10-times more sensitive than conventional PCR and RT-PCR-agarose gel-electrophoresis (PCR-AGE and RT-PCR-AGE). No cross-reaction to each other and to other pathogenic viruses that can infect pigs were observed according to analytical specificity tests. The duplex LAMP-LFD method for the simultaneous detection of PEDV and PCV2 co-infection could be completed within approximately 1.5 h, and only a simple heating block was required for isothermal amplification. The preliminary validation using 50 swine clinical samples with positive and negative PEDV and/or PCV2 revealed that the sensitivity, specificity, and accuracy of duplex LAMP-LFD were all 100% in comparison to conventional PCR and RT-PCR. Hence, this study suggests that duplex LAMP-LFD is a promising tool for the early detection and initial screening of PEDV and PCV2, which could be beneficial for prevention, planning, and epidemiological surveys of these diseases. MDPI 2022-11-03 /pmc/articles/PMC9689611/ /pubmed/36354680 http://dx.doi.org/10.3390/cimb44110368 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Areekit, Supatra
Tangjitrungrot, Pongbun
Khuchareontaworn, Sintawee
Rattanathanawan, Kankanit
Jaratsing, Pornpun
Yasawong, Montri
Chansiri, Gaysorn
Viseshakul, Nareerat
Chansiri, Kosum
Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title_full Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title_fullStr Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title_full_unstemmed Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title_short Development of Duplex LAMP Technique for Detection of Porcine Epidemic Diarrhea Virus (PEDV) and Porcine Circovirus Type 2 (PCV 2)
title_sort development of duplex lamp technique for detection of porcine epidemic diarrhea virus (pedv) and porcine circovirus type 2 (pcv 2)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689611/
https://www.ncbi.nlm.nih.gov/pubmed/36354680
http://dx.doi.org/10.3390/cimb44110368
work_keys_str_mv AT areekitsupatra developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT tangjitrungrotpongbun developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT khuchareontawornsintawee developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT rattanathanawankankanit developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT jaratsingpornpun developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT yasawongmontri developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT chansirigaysorn developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT viseshakulnareerat developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2
AT chansirikosum developmentofduplexlamptechniquefordetectionofporcineepidemicdiarrheaviruspedvandporcinecircovirustype2pcv2