Current Innovative Methods of Fetal pH Monitoring—A Brief Review

In this study, we explore the “why?”, and “how?”, monitoring the pH of the fetal scalp is used, and show its limitations. In addition, we review the development of new devices based on the modern physics and nanomaterials serving this topic. Most of the works we found in our search have focused on i...

Descripción completa

Detalles Bibliográficos
Autores principales: Bohiltea, Roxana-Elena, Mihai, Bianca Margareta, Ducu, Ioniță, Cioca, Ana-Maria, Bohiltea, Alexia-Teodora, Iordache, Ana-Maria, Iordache, Stefan-Marian, Grigorescu, Cristiana Eugenia Ana, Marinescu, Silviu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689968/
https://www.ncbi.nlm.nih.gov/pubmed/36359522
http://dx.doi.org/10.3390/diagnostics12112675
_version_ 1784836668496281600
author Bohiltea, Roxana-Elena
Mihai, Bianca Margareta
Ducu, Ioniță
Cioca, Ana-Maria
Bohiltea, Alexia-Teodora
Iordache, Ana-Maria
Iordache, Stefan-Marian
Grigorescu, Cristiana Eugenia Ana
Marinescu, Silviu
author_facet Bohiltea, Roxana-Elena
Mihai, Bianca Margareta
Ducu, Ioniță
Cioca, Ana-Maria
Bohiltea, Alexia-Teodora
Iordache, Ana-Maria
Iordache, Stefan-Marian
Grigorescu, Cristiana Eugenia Ana
Marinescu, Silviu
author_sort Bohiltea, Roxana-Elena
collection PubMed
description In this study, we explore the “why?”, and “how?”, monitoring the pH of the fetal scalp is used, and show its limitations. In addition, we review the development of new devices based on the modern physics and nanomaterials serving this topic. Most of the works we found in our search have focused on improving the prognostic of fetal heart rate monitoring, because it is the “golden standard” in determining fetal distress. Although the best-known screening method, it can only provide limited information about the actual status of the fetus. The best predictive assessment, with the highest reproducibility, states that a normal fetal heart rate is indicative of a healthy baby. However, its excellent sensitivity is much reduced when identifying the actual “distress”. This is when second-line monitoring methods come into play to guide the diagnostics and direct the obstetrician towards an action plan. Although a historic method, fetal scalp pH sampling is still under review as to its efficiency and place in the current obstetrics. Continuous surveillance of the fetal parameters is important, especially for the fetuses undergoing intrauterine growth restricted (IUGR). Since fetal scalp blood sampling is still under research and is a randomized controlled trial, which compares the relevance of pH and lactates to the obstetrical situation, the maternal-fetal medicine could greatly benefit from the introduction of engineered nanomedicines to the field.
format Online
Article
Text
id pubmed-9689968
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96899682022-11-25 Current Innovative Methods of Fetal pH Monitoring—A Brief Review Bohiltea, Roxana-Elena Mihai, Bianca Margareta Ducu, Ioniță Cioca, Ana-Maria Bohiltea, Alexia-Teodora Iordache, Ana-Maria Iordache, Stefan-Marian Grigorescu, Cristiana Eugenia Ana Marinescu, Silviu Diagnostics (Basel) Review In this study, we explore the “why?”, and “how?”, monitoring the pH of the fetal scalp is used, and show its limitations. In addition, we review the development of new devices based on the modern physics and nanomaterials serving this topic. Most of the works we found in our search have focused on improving the prognostic of fetal heart rate monitoring, because it is the “golden standard” in determining fetal distress. Although the best-known screening method, it can only provide limited information about the actual status of the fetus. The best predictive assessment, with the highest reproducibility, states that a normal fetal heart rate is indicative of a healthy baby. However, its excellent sensitivity is much reduced when identifying the actual “distress”. This is when second-line monitoring methods come into play to guide the diagnostics and direct the obstetrician towards an action plan. Although a historic method, fetal scalp pH sampling is still under review as to its efficiency and place in the current obstetrics. Continuous surveillance of the fetal parameters is important, especially for the fetuses undergoing intrauterine growth restricted (IUGR). Since fetal scalp blood sampling is still under research and is a randomized controlled trial, which compares the relevance of pH and lactates to the obstetrical situation, the maternal-fetal medicine could greatly benefit from the introduction of engineered nanomedicines to the field. MDPI 2022-11-03 /pmc/articles/PMC9689968/ /pubmed/36359522 http://dx.doi.org/10.3390/diagnostics12112675 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Bohiltea, Roxana-Elena
Mihai, Bianca Margareta
Ducu, Ioniță
Cioca, Ana-Maria
Bohiltea, Alexia-Teodora
Iordache, Ana-Maria
Iordache, Stefan-Marian
Grigorescu, Cristiana Eugenia Ana
Marinescu, Silviu
Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title_full Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title_fullStr Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title_full_unstemmed Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title_short Current Innovative Methods of Fetal pH Monitoring—A Brief Review
title_sort current innovative methods of fetal ph monitoring—a brief review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689968/
https://www.ncbi.nlm.nih.gov/pubmed/36359522
http://dx.doi.org/10.3390/diagnostics12112675
work_keys_str_mv AT bohiltearoxanaelena currentinnovativemethodsoffetalphmonitoringabriefreview
AT mihaibiancamargareta currentinnovativemethodsoffetalphmonitoringabriefreview
AT ducuionita currentinnovativemethodsoffetalphmonitoringabriefreview
AT ciocaanamaria currentinnovativemethodsoffetalphmonitoringabriefreview
AT bohilteaalexiateodora currentinnovativemethodsoffetalphmonitoringabriefreview
AT iordacheanamaria currentinnovativemethodsoffetalphmonitoringabriefreview
AT iordachestefanmarian currentinnovativemethodsoffetalphmonitoringabriefreview
AT grigorescucristianaeugeniaana currentinnovativemethodsoffetalphmonitoringabriefreview
AT marinescusilviu currentinnovativemethodsoffetalphmonitoringabriefreview