Cargando…

Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test

In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate)...

Descripción completa

Detalles Bibliográficos
Autores principales: Flieger, Jolanta, Tatarczak-Michalewska, Małgorzata, Flieger, Wojciech, Baj, Jacek, Buszewicz, Grzegorz, Teresiński, Grzegorz, Maciejewski, Ryszard, Wawrzykowski, Jacek, Przygodzka, Dominika, Lutsyk, Valery, Płaziński, Wojciech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691248/
https://www.ncbi.nlm.nih.gov/pubmed/36430168
http://dx.doi.org/10.3390/ijms232213692
_version_ 1784836997963055104
author Flieger, Jolanta
Tatarczak-Michalewska, Małgorzata
Flieger, Wojciech
Baj, Jacek
Buszewicz, Grzegorz
Teresiński, Grzegorz
Maciejewski, Ryszard
Wawrzykowski, Jacek
Przygodzka, Dominika
Lutsyk, Valery
Płaziński, Wojciech
author_facet Flieger, Jolanta
Tatarczak-Michalewska, Małgorzata
Flieger, Wojciech
Baj, Jacek
Buszewicz, Grzegorz
Teresiński, Grzegorz
Maciejewski, Ryszard
Wawrzykowski, Jacek
Przygodzka, Dominika
Lutsyk, Valery
Płaziński, Wojciech
author_sort Flieger, Jolanta
collection PubMed
description In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate) turned out to be the most suitable for direct extraction of hemoglobin into an ionic liquid without the use of any additional reagent at one extraction step. Hemoglobin was separated quantitatively (95% recovery) from the remaining types of proteins remaining in the aqueous phase. Quantum mechanical calculations showed that the interaction of the iron atom in the heme group and the nitrogen atom of the ionic liquid cation is responsible for the transfer of hemoglobin whereas molecular dynamics simulations demonstrated that the non-covalent interactions between heme and solvent are more favorable in the case of OMIM BF(4) in comparison to water. The opposite trend was found for cotinine. Selective isolation of the heme/hemoglobin improved the ELISA test’s accuracy, depending on the cotinine level, from 15% to 30%.
format Online
Article
Text
id pubmed-9691248
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96912482022-11-25 Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test Flieger, Jolanta Tatarczak-Michalewska, Małgorzata Flieger, Wojciech Baj, Jacek Buszewicz, Grzegorz Teresiński, Grzegorz Maciejewski, Ryszard Wawrzykowski, Jacek Przygodzka, Dominika Lutsyk, Valery Płaziński, Wojciech Int J Mol Sci Article In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate) turned out to be the most suitable for direct extraction of hemoglobin into an ionic liquid without the use of any additional reagent at one extraction step. Hemoglobin was separated quantitatively (95% recovery) from the remaining types of proteins remaining in the aqueous phase. Quantum mechanical calculations showed that the interaction of the iron atom in the heme group and the nitrogen atom of the ionic liquid cation is responsible for the transfer of hemoglobin whereas molecular dynamics simulations demonstrated that the non-covalent interactions between heme and solvent are more favorable in the case of OMIM BF(4) in comparison to water. The opposite trend was found for cotinine. Selective isolation of the heme/hemoglobin improved the ELISA test’s accuracy, depending on the cotinine level, from 15% to 30%. MDPI 2022-11-08 /pmc/articles/PMC9691248/ /pubmed/36430168 http://dx.doi.org/10.3390/ijms232213692 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Flieger, Jolanta
Tatarczak-Michalewska, Małgorzata
Flieger, Wojciech
Baj, Jacek
Buszewicz, Grzegorz
Teresiński, Grzegorz
Maciejewski, Ryszard
Wawrzykowski, Jacek
Przygodzka, Dominika
Lutsyk, Valery
Płaziński, Wojciech
Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title_full Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title_fullStr Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title_full_unstemmed Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title_short Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
title_sort influence of selective extraction/isolation of heme/hemoglobin with hydrophobic imidazolium ionic liquids on the precision and accuracy of cotinine elisa test
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691248/
https://www.ncbi.nlm.nih.gov/pubmed/36430168
http://dx.doi.org/10.3390/ijms232213692
work_keys_str_mv AT fliegerjolanta influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT tatarczakmichalewskamałgorzata influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT fliegerwojciech influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT bajjacek influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT buszewiczgrzegorz influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT teresinskigrzegorz influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT maciejewskiryszard influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT wawrzykowskijacek influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT przygodzkadominika influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT lutsykvalery influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest
AT płazinskiwojciech influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest