Cargando…
Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test
In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate)...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691248/ https://www.ncbi.nlm.nih.gov/pubmed/36430168 http://dx.doi.org/10.3390/ijms232213692 |
_version_ | 1784836997963055104 |
---|---|
author | Flieger, Jolanta Tatarczak-Michalewska, Małgorzata Flieger, Wojciech Baj, Jacek Buszewicz, Grzegorz Teresiński, Grzegorz Maciejewski, Ryszard Wawrzykowski, Jacek Przygodzka, Dominika Lutsyk, Valery Płaziński, Wojciech |
author_facet | Flieger, Jolanta Tatarczak-Michalewska, Małgorzata Flieger, Wojciech Baj, Jacek Buszewicz, Grzegorz Teresiński, Grzegorz Maciejewski, Ryszard Wawrzykowski, Jacek Przygodzka, Dominika Lutsyk, Valery Płaziński, Wojciech |
author_sort | Flieger, Jolanta |
collection | PubMed |
description | In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate) turned out to be the most suitable for direct extraction of hemoglobin into an ionic liquid without the use of any additional reagent at one extraction step. Hemoglobin was separated quantitatively (95% recovery) from the remaining types of proteins remaining in the aqueous phase. Quantum mechanical calculations showed that the interaction of the iron atom in the heme group and the nitrogen atom of the ionic liquid cation is responsible for the transfer of hemoglobin whereas molecular dynamics simulations demonstrated that the non-covalent interactions between heme and solvent are more favorable in the case of OMIM BF(4) in comparison to water. The opposite trend was found for cotinine. Selective isolation of the heme/hemoglobin improved the ELISA test’s accuracy, depending on the cotinine level, from 15% to 30%. |
format | Online Article Text |
id | pubmed-9691248 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96912482022-11-25 Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test Flieger, Jolanta Tatarczak-Michalewska, Małgorzata Flieger, Wojciech Baj, Jacek Buszewicz, Grzegorz Teresiński, Grzegorz Maciejewski, Ryszard Wawrzykowski, Jacek Przygodzka, Dominika Lutsyk, Valery Płaziński, Wojciech Int J Mol Sci Article In this study, ionic liquids were used for the selective extraction/isolation of hemoglobin from human serum for cotinine determination using the ELISA Kit. The suitability of hydrophobic imidazolium-based ionic liquids was tested, of which OMIM BF(4) (1-methyl-3-octylimidazolium tetrafluoroborate) turned out to be the most suitable for direct extraction of hemoglobin into an ionic liquid without the use of any additional reagent at one extraction step. Hemoglobin was separated quantitatively (95% recovery) from the remaining types of proteins remaining in the aqueous phase. Quantum mechanical calculations showed that the interaction of the iron atom in the heme group and the nitrogen atom of the ionic liquid cation is responsible for the transfer of hemoglobin whereas molecular dynamics simulations demonstrated that the non-covalent interactions between heme and solvent are more favorable in the case of OMIM BF(4) in comparison to water. The opposite trend was found for cotinine. Selective isolation of the heme/hemoglobin improved the ELISA test’s accuracy, depending on the cotinine level, from 15% to 30%. MDPI 2022-11-08 /pmc/articles/PMC9691248/ /pubmed/36430168 http://dx.doi.org/10.3390/ijms232213692 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Flieger, Jolanta Tatarczak-Michalewska, Małgorzata Flieger, Wojciech Baj, Jacek Buszewicz, Grzegorz Teresiński, Grzegorz Maciejewski, Ryszard Wawrzykowski, Jacek Przygodzka, Dominika Lutsyk, Valery Płaziński, Wojciech Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title | Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title_full | Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title_fullStr | Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title_full_unstemmed | Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title_short | Influence of Selective Extraction/Isolation of Heme/Hemoglobin with Hydrophobic Imidazolium Ionic Liquids on the Precision and Accuracy of Cotinine ELISA Test |
title_sort | influence of selective extraction/isolation of heme/hemoglobin with hydrophobic imidazolium ionic liquids on the precision and accuracy of cotinine elisa test |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691248/ https://www.ncbi.nlm.nih.gov/pubmed/36430168 http://dx.doi.org/10.3390/ijms232213692 |
work_keys_str_mv | AT fliegerjolanta influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT tatarczakmichalewskamałgorzata influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT fliegerwojciech influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT bajjacek influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT buszewiczgrzegorz influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT teresinskigrzegorz influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT maciejewskiryszard influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT wawrzykowskijacek influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT przygodzkadominika influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT lutsykvalery influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest AT płazinskiwojciech influenceofselectiveextractionisolationofhemehemoglobinwithhydrophobicimidazoliumionicliquidsontheprecisionandaccuracyofcotinineelisatest |