Cargando…
Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection
A 52-year-old man presented with a chronic type A(10) aortic dissection with subsequent aneurysmal degeneration of the left common iliac artery measuring up to 4.6 cm. He had previously undergone hemiarch replacement, which was complicated by renal failure. Owing to the presence of the growing aneur...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691463/ https://www.ncbi.nlm.nih.gov/pubmed/36438669 http://dx.doi.org/10.1016/j.jvscit.2022.10.007 |
_version_ | 1784837049954598912 |
---|---|
author | Lin, Jonathan H. Zielke, Tara Zorn, Mary K. Korepta, Lindsey M. Soult, Michael C. Bechara, Carlos F. |
author_facet | Lin, Jonathan H. Zielke, Tara Zorn, Mary K. Korepta, Lindsey M. Soult, Michael C. Bechara, Carlos F. |
author_sort | Lin, Jonathan H. |
collection | PubMed |
description | A 52-year-old man presented with a chronic type A(10) aortic dissection with subsequent aneurysmal degeneration of the left common iliac artery measuring up to 4.6 cm. He had previously undergone hemiarch replacement, which was complicated by renal failure. Owing to the presence of the growing aneurysm, he was unable to be listed for renal transplantation. He declined open operative repair. A novel dual true and false lumen stent graft technique using thoracic endografts was performed to successfully exclude the aneurysm. Follow-up imaging demonstrated aneurysm sac regression, with the patient subsequently undergoing renal transplantation. |
format | Online Article Text |
id | pubmed-9691463 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-96914632022-11-26 Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection Lin, Jonathan H. Zielke, Tara Zorn, Mary K. Korepta, Lindsey M. Soult, Michael C. Bechara, Carlos F. J Vasc Surg Cases Innov Tech Case report A 52-year-old man presented with a chronic type A(10) aortic dissection with subsequent aneurysmal degeneration of the left common iliac artery measuring up to 4.6 cm. He had previously undergone hemiarch replacement, which was complicated by renal failure. Owing to the presence of the growing aneurysm, he was unable to be listed for renal transplantation. He declined open operative repair. A novel dual true and false lumen stent graft technique using thoracic endografts was performed to successfully exclude the aneurysm. Follow-up imaging demonstrated aneurysm sac regression, with the patient subsequently undergoing renal transplantation. Elsevier 2022-10-22 /pmc/articles/PMC9691463/ /pubmed/36438669 http://dx.doi.org/10.1016/j.jvscit.2022.10.007 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case report Lin, Jonathan H. Zielke, Tara Zorn, Mary K. Korepta, Lindsey M. Soult, Michael C. Bechara, Carlos F. Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title | Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title_full | Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title_fullStr | Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title_full_unstemmed | Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title_short | Dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type A(10) dissection |
title_sort | dual true and false lumen stent graft technique for endovascular repair of isolated common iliac artery aneurysm in chronic type a(10) dissection |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691463/ https://www.ncbi.nlm.nih.gov/pubmed/36438669 http://dx.doi.org/10.1016/j.jvscit.2022.10.007 |
work_keys_str_mv | AT linjonathanh dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection AT zielketara dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection AT zornmaryk dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection AT koreptalindseym dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection AT soultmichaelc dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection AT becharacarlosf dualtrueandfalselumenstentgrafttechniqueforendovascularrepairofisolatedcommoniliacarteryaneurysminchronictypea10dissection |