Cargando…

A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection

New sensing platforms based on screen-printed carbon electrodes modified with composites based on polystyrene sulfonate and oxidized multi-walled carbon nanotubes (PSS/MWCNTs-COOH/SPCE) have been used to develop a novel HPLC method with electrochemical detection (ECD) for the determination of the mo...

Descripción completa

Detalles Bibliográficos
Autores principales: Abad-Gil, Lucía, García-Ríos, Mayte, Isabel-Cabrera, Carmen, Gismera, M. Jesús, Sevilla, M. Teresa, Procopio, Jesús R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691489/
https://www.ncbi.nlm.nih.gov/pubmed/36422711
http://dx.doi.org/10.1007/s00604-022-05552-7
_version_ 1784837056103448576
author Abad-Gil, Lucía
García-Ríos, Mayte
Isabel-Cabrera, Carmen
Gismera, M. Jesús
Sevilla, M. Teresa
Procopio, Jesús R.
author_facet Abad-Gil, Lucía
García-Ríos, Mayte
Isabel-Cabrera, Carmen
Gismera, M. Jesús
Sevilla, M. Teresa
Procopio, Jesús R.
author_sort Abad-Gil, Lucía
collection PubMed
description New sensing platforms based on screen-printed carbon electrodes modified with composites based on polystyrene sulfonate and oxidized multi-walled carbon nanotubes (PSS/MWCNTs-COOH/SPCE) have been used to develop a novel HPLC method with electrochemical detection (ECD) for the determination of the most used synthetic phenolic antioxidants in cosmetics: butylhydroxytoluene (BHT), butylhydroxyanisole (BHA), tert-butylhydroquinone (TBHQ) and propyl gallate (PG). Optimal separation conditions were achieved using methanol: 0.10 mol L(−1) acetate solution at pH 6 as mobile phase with a gradient elution program from 60 to 90% of methanol percentage in 15 min. The electrochemical detection was carried out in amperometric mode using the PSS/MWCNTs-COOH/SPCE at + 0.80 V vs. Ag. Under these optimal separation and detection conditions, the limits of detection (LOD) were between 0.11 and 0.25 mg L(−1). These LOD values were better, especially for BHT, than those previously published in other HPLC methods. Linear ranges from 0.37 mg L(−1), 0.83 mg L(−1), 0.69 mg L(−1) and 0.56 mg L(−1) to 10 mg L(−1) were obtained for PG, TBHQ, BHA and BHT, respectively. RSD values equal or lower than 5% and 8% were achieved for repeatability and reproducibility, respectively. The HPLC-ECD method was successfully applied to analyze different cosmetic samples. Recovery values within 83–109% were obtained in the validation studies. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-022-05552-7.
format Online
Article
Text
id pubmed-9691489
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-96914892022-11-26 A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection Abad-Gil, Lucía García-Ríos, Mayte Isabel-Cabrera, Carmen Gismera, M. Jesús Sevilla, M. Teresa Procopio, Jesús R. Mikrochim Acta Original Paper New sensing platforms based on screen-printed carbon electrodes modified with composites based on polystyrene sulfonate and oxidized multi-walled carbon nanotubes (PSS/MWCNTs-COOH/SPCE) have been used to develop a novel HPLC method with electrochemical detection (ECD) for the determination of the most used synthetic phenolic antioxidants in cosmetics: butylhydroxytoluene (BHT), butylhydroxyanisole (BHA), tert-butylhydroquinone (TBHQ) and propyl gallate (PG). Optimal separation conditions were achieved using methanol: 0.10 mol L(−1) acetate solution at pH 6 as mobile phase with a gradient elution program from 60 to 90% of methanol percentage in 15 min. The electrochemical detection was carried out in amperometric mode using the PSS/MWCNTs-COOH/SPCE at + 0.80 V vs. Ag. Under these optimal separation and detection conditions, the limits of detection (LOD) were between 0.11 and 0.25 mg L(−1). These LOD values were better, especially for BHT, than those previously published in other HPLC methods. Linear ranges from 0.37 mg L(−1), 0.83 mg L(−1), 0.69 mg L(−1) and 0.56 mg L(−1) to 10 mg L(−1) were obtained for PG, TBHQ, BHA and BHT, respectively. RSD values equal or lower than 5% and 8% were achieved for repeatability and reproducibility, respectively. The HPLC-ECD method was successfully applied to analyze different cosmetic samples. Recovery values within 83–109% were obtained in the validation studies. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-022-05552-7. Springer Vienna 2022-11-24 2022 /pmc/articles/PMC9691489/ /pubmed/36422711 http://dx.doi.org/10.1007/s00604-022-05552-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Abad-Gil, Lucía
García-Ríos, Mayte
Isabel-Cabrera, Carmen
Gismera, M. Jesús
Sevilla, M. Teresa
Procopio, Jesús R.
A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title_full A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title_fullStr A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title_full_unstemmed A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title_short A MWCNTs-COOH/PSS nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by HPLC with amperometric detection
title_sort mwcnts-cooh/pss nanocomposite–modified screen-printed electrode for the determination of synthetic phenolic antioxidants by hplc with amperometric detection
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691489/
https://www.ncbi.nlm.nih.gov/pubmed/36422711
http://dx.doi.org/10.1007/s00604-022-05552-7
work_keys_str_mv AT abadgillucia amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT garciariosmayte amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT isabelcabreracarmen amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT gismeramjesus amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT sevillamteresa amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT procopiojesusr amwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT abadgillucia mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT garciariosmayte mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT isabelcabreracarmen mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT gismeramjesus mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT sevillamteresa mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection
AT procopiojesusr mwcntscoohpssnanocompositemodifiedscreenprintedelectrodeforthedeterminationofsyntheticphenolicantioxidantsbyhplcwithamperometricdetection