Cargando…
Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer
Microvibration induced by natural disturbance and human activities has an adverse effect on the operation of the large-scale and ultraprecise facilities in the world. Under such circumstances, a passive vibration control method is generally deployed for such vibration-sensitive facilities, taking th...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691740/ https://www.ncbi.nlm.nih.gov/pubmed/36424416 http://dx.doi.org/10.1038/s41598-022-23173-1 |
_version_ | 1784837094771785728 |
---|---|
author | Zheng, Ming Zhuang, Liangdong Fan, Jiansheng Liu, Yufei Ren, Jinlong Rong, Muning Zhai, Wei |
author_facet | Zheng, Ming Zhuang, Liangdong Fan, Jiansheng Liu, Yufei Ren, Jinlong Rong, Muning Zhai, Wei |
author_sort | Zheng, Ming |
collection | PubMed |
description | Microvibration induced by natural disturbance and human activities has an adverse effect on the operation of the large-scale and ultraprecise facilities in the world. Under such circumstances, a passive vibration control method is generally deployed for such vibration-sensitive facilities, taking the High Energy Photo Source (HEPS) in Beijing as an example, a 3 m-thick mass concrete layer forming a ring foundation was cast at the facility, where a 1 m-thick reinforced concrete slab (RC slab) lies. Since microvibration control plays a crucial role in the operation of such large-scale scientific and ultraprecise facilities and few studies have been reported for large-scale concrete layer as antimicrovibration devices, this paper presents four field tests in Beijing, China, to evaluate the vibration control capacity of a mass concrete layer. Based on a large number of field tests, the effect of applying the concrete layer is discussed, and a reference is provided for the construction of similar facilities. The vibration signals, generated by shock excitation and ambient excitation, are measured through a highly sensitive and high-accuracy vibration acquisition system. It is concluded that the existence of the 1 m-thick RC slab has little influence on the microvibration signal frequency distribution in the vertical direction and that the signals from the concrete layer and subsoil differ by approximately 10 Hz in the vertical direction while differing by approximately 5 Hz in the horizontal direction. The microvibration control ability of the concrete layer is favorable in a higher frequency band over 20 ~ 30 Hz and more than 50% attenuation can be gained through the concrete layer; however, the microvibration control ability is not significant below 20 ~ 30 Hz. The vibration levels across different heights of the concrete layer section are the same. To prevent adverse vibration disturbance below 20 ~ 30 Hz, it is suggested that the traffic and road surface conditions should be taken into consideration when choosing the construction location. In addition, a long-term monitoring shows that 75% vibration energy at the site is firmly related to the construction activities which are approximately 1.4 km from the site. |
format | Online Article Text |
id | pubmed-9691740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-96917402022-11-26 Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer Zheng, Ming Zhuang, Liangdong Fan, Jiansheng Liu, Yufei Ren, Jinlong Rong, Muning Zhai, Wei Sci Rep Article Microvibration induced by natural disturbance and human activities has an adverse effect on the operation of the large-scale and ultraprecise facilities in the world. Under such circumstances, a passive vibration control method is generally deployed for such vibration-sensitive facilities, taking the High Energy Photo Source (HEPS) in Beijing as an example, a 3 m-thick mass concrete layer forming a ring foundation was cast at the facility, where a 1 m-thick reinforced concrete slab (RC slab) lies. Since microvibration control plays a crucial role in the operation of such large-scale scientific and ultraprecise facilities and few studies have been reported for large-scale concrete layer as antimicrovibration devices, this paper presents four field tests in Beijing, China, to evaluate the vibration control capacity of a mass concrete layer. Based on a large number of field tests, the effect of applying the concrete layer is discussed, and a reference is provided for the construction of similar facilities. The vibration signals, generated by shock excitation and ambient excitation, are measured through a highly sensitive and high-accuracy vibration acquisition system. It is concluded that the existence of the 1 m-thick RC slab has little influence on the microvibration signal frequency distribution in the vertical direction and that the signals from the concrete layer and subsoil differ by approximately 10 Hz in the vertical direction while differing by approximately 5 Hz in the horizontal direction. The microvibration control ability of the concrete layer is favorable in a higher frequency band over 20 ~ 30 Hz and more than 50% attenuation can be gained through the concrete layer; however, the microvibration control ability is not significant below 20 ~ 30 Hz. The vibration levels across different heights of the concrete layer section are the same. To prevent adverse vibration disturbance below 20 ~ 30 Hz, it is suggested that the traffic and road surface conditions should be taken into consideration when choosing the construction location. In addition, a long-term monitoring shows that 75% vibration energy at the site is firmly related to the construction activities which are approximately 1.4 km from the site. Nature Publishing Group UK 2022-11-24 /pmc/articles/PMC9691740/ /pubmed/36424416 http://dx.doi.org/10.1038/s41598-022-23173-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Zheng, Ming Zhuang, Liangdong Fan, Jiansheng Liu, Yufei Ren, Jinlong Rong, Muning Zhai, Wei Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title | Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title_full | Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title_fullStr | Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title_full_unstemmed | Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title_short | Field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
title_sort | field test study on the evaluation of the microvibration controlling capacity of a mass concrete layer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9691740/ https://www.ncbi.nlm.nih.gov/pubmed/36424416 http://dx.doi.org/10.1038/s41598-022-23173-1 |
work_keys_str_mv | AT zhengming fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT zhuangliangdong fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT fanjiansheng fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT liuyufei fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT renjinlong fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT rongmuning fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer AT zhaiwei fieldteststudyontheevaluationofthemicrovibrationcontrollingcapacityofamassconcretelayer |