Cargando…

Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair

OBJECTIVE: Predicting success after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) relies on measurements of aneurysm sac regression. However, in the absence of regression, morphometric analysis alone is insufficient to reliably predict the successful remodeling of AAAs aft...

Descripción completa

Detalles Bibliográficos
Autores principales: Zottola, Zachary R., Gonring, Dakota W., Wang, Maxwell L., Hirad, Adnan A., Richards, Michael S., Stoner, Michael C., Mix, Doran S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692035/
https://www.ncbi.nlm.nih.gov/pubmed/36438670
http://dx.doi.org/10.1016/j.jvscit.2022.09.003
_version_ 1784837170181177344
author Zottola, Zachary R.
Gonring, Dakota W.
Wang, Maxwell L.
Hirad, Adnan A.
Richards, Michael S.
Stoner, Michael C.
Mix, Doran S.
author_facet Zottola, Zachary R.
Gonring, Dakota W.
Wang, Maxwell L.
Hirad, Adnan A.
Richards, Michael S.
Stoner, Michael C.
Mix, Doran S.
author_sort Zottola, Zachary R.
collection PubMed
description OBJECTIVE: Predicting success after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) relies on measurements of aneurysm sac regression. However, in the absence of regression, morphometric analysis alone is insufficient to reliably predict the successful remodeling of AAAs after EVAR. Biomechanical parameters, such as pressure-normalized principal strain, might provide useful information in the post-EVAR AAA assessment. Our objective was to assess the feasibility of our novel ultrasound elastography (USE) technique to detect changes in the aortic wall principal strain in patients who had undergone EVAR and determine the temporal nature of the biomechanical changes in the aorta. METHODS: USE images were obtained from patients undergoing elective EVAR intraoperatively, immediately before and after endograft implantation, and at their 30-day follow-up. The maximal mean principal strain ([Formula: see text]) for each scan was assessed using our novel technique, which uses a finite element mesh to track the frame-to-frame displacements of the aortic wall over one cardiac cycle. The [Formula: see text] in the user-defined aortic wall was then divided by the pulse pressure at the time of the scan to produce a pressure-normalized strain measurement ([Formula: see text] /PP), a surrogate for tissue stiffness. Paired t tests were used to compare the pre- and postoperative [Formula: see text] /PP and the postoperative and 30-day [Formula: see text] /PP. Patient 30-day sac regression and endoleak data were collected by a review of 30-day follow-up computed tomography scans. RESULTS: USE analysis of the data from 12 patients demonstrated a significant reduction in aortic wall [Formula: see text] /PP (average, 0.191% ± 0.09%/kPa vs 0.087% ± 0.04%/kPa; P = .002) immediately after graft implantation, with a nonsignificant change in the [Formula: see text] /PP (0.091% ± 0.04%/kPa vs 0.102% ± 0.05%/kPa; P = .47) from postoperatively to 30-day follow-up. This represents an average 46.5% reduction after stent placement, with a nonsignificant 18.1% increase at 30-day follow-up. All the patients showed sac stability, except for two patients who had demonstrated 7.3-mm and 6.8-mm sac regressions. CONCLUSIONS: Our analysis has demonstrated that the presented USE technique is a feasible method for detecting significant reductions in aortic [Formula: see text] /PP intraoperatively after EVAR. We found that patients undergoing EVAR will experience large reductions in the [Formula: see text] /PP intraoperatively after graft implantation, with stabilization found at their 30-day follow-up. These preliminary data have shown that an intraoperative [Formula: see text] /PP reduction could be a promising correlate of post-EVAR aneurysm remodeling. Our results have also suggested that endograft design likely plays a large role in determining the aneurysm biomechanical changes immediately after implantation.
format Online
Article
Text
id pubmed-9692035
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-96920352022-11-26 Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair Zottola, Zachary R. Gonring, Dakota W. Wang, Maxwell L. Hirad, Adnan A. Richards, Michael S. Stoner, Michael C. Mix, Doran S. J Vasc Surg Cases Innov Tech Innovations in clinical care OBJECTIVE: Predicting success after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) relies on measurements of aneurysm sac regression. However, in the absence of regression, morphometric analysis alone is insufficient to reliably predict the successful remodeling of AAAs after EVAR. Biomechanical parameters, such as pressure-normalized principal strain, might provide useful information in the post-EVAR AAA assessment. Our objective was to assess the feasibility of our novel ultrasound elastography (USE) technique to detect changes in the aortic wall principal strain in patients who had undergone EVAR and determine the temporal nature of the biomechanical changes in the aorta. METHODS: USE images were obtained from patients undergoing elective EVAR intraoperatively, immediately before and after endograft implantation, and at their 30-day follow-up. The maximal mean principal strain ([Formula: see text]) for each scan was assessed using our novel technique, which uses a finite element mesh to track the frame-to-frame displacements of the aortic wall over one cardiac cycle. The [Formula: see text] in the user-defined aortic wall was then divided by the pulse pressure at the time of the scan to produce a pressure-normalized strain measurement ([Formula: see text] /PP), a surrogate for tissue stiffness. Paired t tests were used to compare the pre- and postoperative [Formula: see text] /PP and the postoperative and 30-day [Formula: see text] /PP. Patient 30-day sac regression and endoleak data were collected by a review of 30-day follow-up computed tomography scans. RESULTS: USE analysis of the data from 12 patients demonstrated a significant reduction in aortic wall [Formula: see text] /PP (average, 0.191% ± 0.09%/kPa vs 0.087% ± 0.04%/kPa; P = .002) immediately after graft implantation, with a nonsignificant change in the [Formula: see text] /PP (0.091% ± 0.04%/kPa vs 0.102% ± 0.05%/kPa; P = .47) from postoperatively to 30-day follow-up. This represents an average 46.5% reduction after stent placement, with a nonsignificant 18.1% increase at 30-day follow-up. All the patients showed sac stability, except for two patients who had demonstrated 7.3-mm and 6.8-mm sac regressions. CONCLUSIONS: Our analysis has demonstrated that the presented USE technique is a feasible method for detecting significant reductions in aortic [Formula: see text] /PP intraoperatively after EVAR. We found that patients undergoing EVAR will experience large reductions in the [Formula: see text] /PP intraoperatively after graft implantation, with stabilization found at their 30-day follow-up. These preliminary data have shown that an intraoperative [Formula: see text] /PP reduction could be a promising correlate of post-EVAR aneurysm remodeling. Our results have also suggested that endograft design likely plays a large role in determining the aneurysm biomechanical changes immediately after implantation. Elsevier 2022-09-19 /pmc/articles/PMC9692035/ /pubmed/36438670 http://dx.doi.org/10.1016/j.jvscit.2022.09.003 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Innovations in clinical care
Zottola, Zachary R.
Gonring, Dakota W.
Wang, Maxwell L.
Hirad, Adnan A.
Richards, Michael S.
Stoner, Michael C.
Mix, Doran S.
Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title_full Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title_fullStr Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title_full_unstemmed Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title_short Changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
title_sort changes in intraoperative aortic strain as detected by ultrasound elastography in patients following abdominal endovascular aneurysm repair
topic Innovations in clinical care
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692035/
https://www.ncbi.nlm.nih.gov/pubmed/36438670
http://dx.doi.org/10.1016/j.jvscit.2022.09.003
work_keys_str_mv AT zottolazacharyr changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT gonringdakotaw changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT wangmaxwelll changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT hiradadnana changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT richardsmichaels changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT stonermichaelc changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair
AT mixdorans changesinintraoperativeaorticstrainasdetectedbyultrasoundelastographyinpatientsfollowingabdominalendovascularaneurysmrepair