Cargando…

Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance

In recent years, CID sensors have displayed great development potential in parameter measurement of gas–liquid two-phase flow in small channels. However, the fundamental/mechanism research on the response characteristics of CID sensors is relatively insufficient. This work focuses on the investigati...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chenxu, Huang, Junchao, Ji, Haifeng, Huang, Zhiyao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692662/
https://www.ncbi.nlm.nih.gov/pubmed/36433583
http://dx.doi.org/10.3390/s22228987
_version_ 1784837323948556288
author Wang, Chenxu
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
author_facet Wang, Chenxu
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
author_sort Wang, Chenxu
collection PubMed
description In recent years, CID sensors have displayed great development potential in parameter measurement of gas–liquid two-phase flow in small channels. However, the fundamental/mechanism research on the response characteristics of CID sensors is relatively insufficient. This work focuses on the investigation of the influence of separation distance between slugs on the impedance (real part, imaginary part and amplitude) response characteristics of slug flow in small channels. Experiments were carried out with the CID sensors in four small channels with inner pipe diameters of 1.96 mm, 2.48 mm, 3.02 mm and 3.54 mm, respectively. The experimental results show that for a CID sensor, the slug separation distance has significant influence on the impedance response characteristics. There is a critical value of slug separation distance. When the slug separation distance is larger than the critical value, the impedance response characteristics of each slug can be considered independent of each other, i.e., there is no interaction between the slugs. When the slug separation distance is less than the critical value, the impedance response characteristics show obvious interaction between the slugs. It is indicated that the ratios of the critical values to the pipe inner diameters are approximate 100.
format Online
Article
Text
id pubmed-9692662
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96926622022-11-26 Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance Wang, Chenxu Huang, Junchao Ji, Haifeng Huang, Zhiyao Sensors (Basel) Communication In recent years, CID sensors have displayed great development potential in parameter measurement of gas–liquid two-phase flow in small channels. However, the fundamental/mechanism research on the response characteristics of CID sensors is relatively insufficient. This work focuses on the investigation of the influence of separation distance between slugs on the impedance (real part, imaginary part and amplitude) response characteristics of slug flow in small channels. Experiments were carried out with the CID sensors in four small channels with inner pipe diameters of 1.96 mm, 2.48 mm, 3.02 mm and 3.54 mm, respectively. The experimental results show that for a CID sensor, the slug separation distance has significant influence on the impedance response characteristics. There is a critical value of slug separation distance. When the slug separation distance is larger than the critical value, the impedance response characteristics of each slug can be considered independent of each other, i.e., there is no interaction between the slugs. When the slug separation distance is less than the critical value, the impedance response characteristics show obvious interaction between the slugs. It is indicated that the ratios of the critical values to the pipe inner diameters are approximate 100. MDPI 2022-11-20 /pmc/articles/PMC9692662/ /pubmed/36433583 http://dx.doi.org/10.3390/s22228987 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Wang, Chenxu
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title_full Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title_fullStr Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title_full_unstemmed Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title_short Response Characteristics of Contactless Impedance Detection (CID) Sensor on Slug Flow in Small Channels: The Investigation on Slug Separation Distance
title_sort response characteristics of contactless impedance detection (cid) sensor on slug flow in small channels: the investigation on slug separation distance
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692662/
https://www.ncbi.nlm.nih.gov/pubmed/36433583
http://dx.doi.org/10.3390/s22228987
work_keys_str_mv AT wangchenxu responsecharacteristicsofcontactlessimpedancedetectioncidsensoronslugflowinsmallchannelstheinvestigationonslugseparationdistance
AT huangjunchao responsecharacteristicsofcontactlessimpedancedetectioncidsensoronslugflowinsmallchannelstheinvestigationonslugseparationdistance
AT jihaifeng responsecharacteristicsofcontactlessimpedancedetectioncidsensoronslugflowinsmallchannelstheinvestigationonslugseparationdistance
AT huangzhiyao responsecharacteristicsofcontactlessimpedancedetectioncidsensoronslugflowinsmallchannelstheinvestigationonslugseparationdistance