Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy
Background and Objectives: Recurrent laryngeal nerve (RLN) paralysis is a fearful complication during thyroidectomy. Intraoperative neuromonitoring (IONM) and optical magnification (OM) facilitate RLN identification and dissection. The purpose of our study was to evaluate the influence of the two te...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692813/ https://www.ncbi.nlm.nih.gov/pubmed/36363517 http://dx.doi.org/10.3390/medicina58111560 |
_version_ | 1784837363152715776 |
---|---|
author | Karpathiotakis, Menelaos D’Orazi, Valerio Ortensi, Andrea Biancucci, Andrea Melcarne, Rossella Borcea, Maria Carola Scorziello, Chiara Tartaglia, Francesco |
author_facet | Karpathiotakis, Menelaos D’Orazi, Valerio Ortensi, Andrea Biancucci, Andrea Melcarne, Rossella Borcea, Maria Carola Scorziello, Chiara Tartaglia, Francesco |
author_sort | Karpathiotakis, Menelaos |
collection | PubMed |
description | Background and Objectives: Recurrent laryngeal nerve (RLN) paralysis is a fearful complication during thyroidectomy. Intraoperative neuromonitoring (IONM) and optical magnification (OM) facilitate RLN identification and dissection. The purpose of our study was to evaluate the influence of the two techniques on the incidence of RLN paralysis and determine correlations regarding common outcomes in thyroid surgery. Materials and Methods: Two equally sized groups of 50 patients who underwent total thyroidectomies were examined. In the first group (OM), only surgical binocular loupes (2.5×–4.5×) were used during surgery, while in the second group (IONM), the intermittent NIM was applied. Results: Both the operative time and the length of hospitalization were shorter in the OM group than in the IONM group (median 80 versus 100 min and median 2 versus 4 days, respectively) (p < 0.05). The male patients were found to have a five-fold higher risk of developing transient dysphonia than the females (adjusted OR 5.19, 95% IC 0.99–27.18, p = 0.05). The OM group reported a four-fold higher risk of developing transient hypocalcemia than the IONM group (OR 3.78, adjusted OR 4.11, p = 0.01). Despite two cases of temporary bilateral RLN paralysis in the IONM group versus none in the OM group, no statistically significant difference was found (p > 0.05). No permanent RLN paralysis or hypoparathyroidism have been reported. Conclusions: Despite some limitations, our study is the first to compare the use of IONM with OM alone in the prevention of RLN injuries. The risk of recurrent complications remains comparable and both techniques can be considered valid instruments, especially if applied simultaneously by surgeons. |
format | Online Article Text |
id | pubmed-9692813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96928132022-11-26 Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy Karpathiotakis, Menelaos D’Orazi, Valerio Ortensi, Andrea Biancucci, Andrea Melcarne, Rossella Borcea, Maria Carola Scorziello, Chiara Tartaglia, Francesco Medicina (Kaunas) Article Background and Objectives: Recurrent laryngeal nerve (RLN) paralysis is a fearful complication during thyroidectomy. Intraoperative neuromonitoring (IONM) and optical magnification (OM) facilitate RLN identification and dissection. The purpose of our study was to evaluate the influence of the two techniques on the incidence of RLN paralysis and determine correlations regarding common outcomes in thyroid surgery. Materials and Methods: Two equally sized groups of 50 patients who underwent total thyroidectomies were examined. In the first group (OM), only surgical binocular loupes (2.5×–4.5×) were used during surgery, while in the second group (IONM), the intermittent NIM was applied. Results: Both the operative time and the length of hospitalization were shorter in the OM group than in the IONM group (median 80 versus 100 min and median 2 versus 4 days, respectively) (p < 0.05). The male patients were found to have a five-fold higher risk of developing transient dysphonia than the females (adjusted OR 5.19, 95% IC 0.99–27.18, p = 0.05). The OM group reported a four-fold higher risk of developing transient hypocalcemia than the IONM group (OR 3.78, adjusted OR 4.11, p = 0.01). Despite two cases of temporary bilateral RLN paralysis in the IONM group versus none in the OM group, no statistically significant difference was found (p > 0.05). No permanent RLN paralysis or hypoparathyroidism have been reported. Conclusions: Despite some limitations, our study is the first to compare the use of IONM with OM alone in the prevention of RLN injuries. The risk of recurrent complications remains comparable and both techniques can be considered valid instruments, especially if applied simultaneously by surgeons. MDPI 2022-10-30 /pmc/articles/PMC9692813/ /pubmed/36363517 http://dx.doi.org/10.3390/medicina58111560 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Karpathiotakis, Menelaos D’Orazi, Valerio Ortensi, Andrea Biancucci, Andrea Melcarne, Rossella Borcea, Maria Carola Scorziello, Chiara Tartaglia, Francesco Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title | Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title_full | Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title_fullStr | Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title_full_unstemmed | Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title_short | Intraoperative Neuromonitoring and Optical Magnification in the Prevention of Recurrent Laryngeal Nerve Injuries during Total Thyroidectomy |
title_sort | intraoperative neuromonitoring and optical magnification in the prevention of recurrent laryngeal nerve injuries during total thyroidectomy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692813/ https://www.ncbi.nlm.nih.gov/pubmed/36363517 http://dx.doi.org/10.3390/medicina58111560 |
work_keys_str_mv | AT karpathiotakismenelaos intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT dorazivalerio intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT ortensiandrea intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT biancucciandrea intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT melcarnerossella intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT borceamariacarola intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT scorziellochiara intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy AT tartagliafrancesco intraoperativeneuromonitoringandopticalmagnificationinthepreventionofrecurrentlaryngealnerveinjuriesduringtotalthyroidectomy |