Cargando…

Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement

The article analyses the influence, relationship and value of the design parameters of the thermal flowmeter on its radial and axial heat fluxes in the tube. The purpose of the analyses is to check the change in the error of fuel flow measurement by the thermal flowmeter directly on the vehicle when...

Descripción completa

Detalles Bibliográficos
Autores principales: Korobiichuk, Igor, Ilchenko, Andrii
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692935/
https://www.ncbi.nlm.nih.gov/pubmed/36433478
http://dx.doi.org/10.3390/s22228882
_version_ 1784837400668667904
author Korobiichuk, Igor
Ilchenko, Andrii
author_facet Korobiichuk, Igor
Ilchenko, Andrii
author_sort Korobiichuk, Igor
collection PubMed
description The article analyses the influence, relationship and value of the design parameters of the thermal flowmeter on its radial and axial heat fluxes in the tube. The purpose of the analyses is to check the change in the error of fuel flow measurement by the thermal flowmeter directly on the vehicle when using heating elements of different diameters. The influence of the radial heat flux of the flowmeter tube on the accuracy of fuel flow measurement is substantiated. Recommendations on the choice of design parameters of a thermal flowmeter at the stage of its design, development or use are developed under the condition of reducing the influence of the radial heat flow on the axial one, which will reduce the total error in the measurement of fuel flow rate.
format Online
Article
Text
id pubmed-9692935
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96929352022-11-26 Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement Korobiichuk, Igor Ilchenko, Andrii Sensors (Basel) Communication The article analyses the influence, relationship and value of the design parameters of the thermal flowmeter on its radial and axial heat fluxes in the tube. The purpose of the analyses is to check the change in the error of fuel flow measurement by the thermal flowmeter directly on the vehicle when using heating elements of different diameters. The influence of the radial heat flux of the flowmeter tube on the accuracy of fuel flow measurement is substantiated. Recommendations on the choice of design parameters of a thermal flowmeter at the stage of its design, development or use are developed under the condition of reducing the influence of the radial heat flow on the axial one, which will reduce the total error in the measurement of fuel flow rate. MDPI 2022-11-17 /pmc/articles/PMC9692935/ /pubmed/36433478 http://dx.doi.org/10.3390/s22228882 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Korobiichuk, Igor
Ilchenko, Andrii
Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title_full Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title_fullStr Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title_full_unstemmed Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title_short Optimal Design Parameters of Thermal Flowmeter for Fuel Flow Measurement
title_sort optimal design parameters of thermal flowmeter for fuel flow measurement
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692935/
https://www.ncbi.nlm.nih.gov/pubmed/36433478
http://dx.doi.org/10.3390/s22228882
work_keys_str_mv AT korobiichukigor optimaldesignparametersofthermalflowmeterforfuelflowmeasurement
AT ilchenkoandrii optimaldesignparametersofthermalflowmeterforfuelflowmeasurement