Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals

Nondestructive testing (NDT) is an essential method for assessing structural integrity in the oil and gas industry. Electromagnetic acoustic transducers (EMATs) have been extensively used to detect the wall-thickness reduction of plate-like structures, because they do not require direct contact. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Junjie, Wu, Xinjun, Song, Yun, Sun, Lingsi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692993/
https://www.ncbi.nlm.nih.gov/pubmed/36433337
http://dx.doi.org/10.3390/s22228741
_version_ 1784837417551790080
author Wang, Junjie
Wu, Xinjun
Song, Yun
Sun, Lingsi
author_facet Wang, Junjie
Wu, Xinjun
Song, Yun
Sun, Lingsi
author_sort Wang, Junjie
collection PubMed
description Nondestructive testing (NDT) is an essential method for assessing structural integrity in the oil and gas industry. Electromagnetic acoustic transducers (EMATs) have been extensively used to detect the wall-thickness reduction of plate-like structures, because they do not require direct contact. The pulse intervals of echoes are used to calculate the remnant thickness of structures. If the width of a single pulse is too large, multiple pulses will be superimposed, making it more difficult to extract the pulse interval. Thus, the width of a single pulse affects the resolution of measurements. This paper investigates the impacts of the backplate position on the pulse width and amplitude of thickness-measurement signals, using EMATs. By means of impedance modeling and measurement, it can be shown that the output impedance of the receiving coil is strongly influenced by the coil-backplate gap. With the increment in the coil-backplate gap, the signal amplitude and damping coefficient increase, while the self-resonant frequency decreases. By means of signal measurements on the specimen, it is shown that the pulse width and the signal amplitude can be significantly influenced by the backplate position. By reducing the coil–backplate gap, the pulse width can be reduced by over 80%, and by increasing the gap, the signal amplitude can be increased by over 300%. These research results can be used to optimize EMAT design, thereby suppressing the superposition of pulse echoes.
format Online
Article
Text
id pubmed-9692993
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96929932022-11-26 Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals Wang, Junjie Wu, Xinjun Song, Yun Sun, Lingsi Sensors (Basel) Article Nondestructive testing (NDT) is an essential method for assessing structural integrity in the oil and gas industry. Electromagnetic acoustic transducers (EMATs) have been extensively used to detect the wall-thickness reduction of plate-like structures, because they do not require direct contact. The pulse intervals of echoes are used to calculate the remnant thickness of structures. If the width of a single pulse is too large, multiple pulses will be superimposed, making it more difficult to extract the pulse interval. Thus, the width of a single pulse affects the resolution of measurements. This paper investigates the impacts of the backplate position on the pulse width and amplitude of thickness-measurement signals, using EMATs. By means of impedance modeling and measurement, it can be shown that the output impedance of the receiving coil is strongly influenced by the coil-backplate gap. With the increment in the coil-backplate gap, the signal amplitude and damping coefficient increase, while the self-resonant frequency decreases. By means of signal measurements on the specimen, it is shown that the pulse width and the signal amplitude can be significantly influenced by the backplate position. By reducing the coil–backplate gap, the pulse width can be reduced by over 80%, and by increasing the gap, the signal amplitude can be increased by over 300%. These research results can be used to optimize EMAT design, thereby suppressing the superposition of pulse echoes. MDPI 2022-11-12 /pmc/articles/PMC9692993/ /pubmed/36433337 http://dx.doi.org/10.3390/s22228741 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Junjie
Wu, Xinjun
Song, Yun
Sun, Lingsi
Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title_full Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title_fullStr Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title_full_unstemmed Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title_short Study of the Influence of the Backplate Position on EMAT Thickness-Measurement Signals
title_sort study of the influence of the backplate position on emat thickness-measurement signals
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9692993/
https://www.ncbi.nlm.nih.gov/pubmed/36433337
http://dx.doi.org/10.3390/s22228741
work_keys_str_mv AT wangjunjie studyoftheinfluenceofthebackplatepositiononematthicknessmeasurementsignals
AT wuxinjun studyoftheinfluenceofthebackplatepositiononematthicknessmeasurementsignals
AT songyun studyoftheinfluenceofthebackplatepositiononematthicknessmeasurementsignals
AT sunlingsi studyoftheinfluenceofthebackplatepositiononematthicknessmeasurementsignals