Cargando…

A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events

Background and Objectives: Cardiovascular diseases are the main cause of death worldwide, and pulse wave velocity (PWV) is considered a predictor of major adverse cardiovascular events. The study intended to be helpful in finding methods for the preliminary assessment of PWV in primary care units. M...

Descripción completa

Detalles Bibliográficos
Autores principales: Marin, Ioana, Popescu, Florina Georgeta, Pauncu, Elena-Ana, Apostol, Adrian, Ivan, Viviana Mihaela, Marin, Catalin Nicolae, Fira-Mladinescu, Ovidiu, Ursoniu, Sorin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9693976/
https://www.ncbi.nlm.nih.gov/pubmed/36422172
http://dx.doi.org/10.3390/medicina58111633
_version_ 1784837680782114816
author Marin, Ioana
Popescu, Florina Georgeta
Pauncu, Elena-Ana
Apostol, Adrian
Ivan, Viviana Mihaela
Marin, Catalin Nicolae
Fira-Mladinescu, Ovidiu
Ursoniu, Sorin
author_facet Marin, Ioana
Popescu, Florina Georgeta
Pauncu, Elena-Ana
Apostol, Adrian
Ivan, Viviana Mihaela
Marin, Catalin Nicolae
Fira-Mladinescu, Ovidiu
Ursoniu, Sorin
author_sort Marin, Ioana
collection PubMed
description Background and Objectives: Cardiovascular diseases are the main cause of death worldwide, and pulse wave velocity (PWV) is considered a predictor of major adverse cardiovascular events. The study intended to be helpful in finding methods for the preliminary assessment of PWV in primary care units. Materials and Methods: The study group consisted of 36 subjects (considered healthy by their own statement) from the medical field (medicine students and residents) aged between 20 and 30 years: 33.3% males and 66.7% females. Two types of measurements were carried out successively: (a) measurements with the arteriograph and (b) measurements on a treadmill effort testing system, where heart rate (HR) was measured over time as a response to step function physical effort (PE). Results: The study allowed for the highlighting of some limits which, if exceeded, can be associated with high PWV values: (i) if after a moderate PE and a resting time of at least 6 min, the HR is larger than 80 b/min; (ii) if the relaxation time in a PE test of moderate intensity is larger than 1 min; (iii) if the HR measured after the subject is raised from the supine to orthostatic position is larger than 100 b/min, and (iv) if the resting HR is larger than 80 b/min. Conclusions: Steady-state HR correlates with PWV and may be used for the preliminary assessment of PWV.
format Online
Article
Text
id pubmed-9693976
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96939762022-11-26 A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events Marin, Ioana Popescu, Florina Georgeta Pauncu, Elena-Ana Apostol, Adrian Ivan, Viviana Mihaela Marin, Catalin Nicolae Fira-Mladinescu, Ovidiu Ursoniu, Sorin Medicina (Kaunas) Article Background and Objectives: Cardiovascular diseases are the main cause of death worldwide, and pulse wave velocity (PWV) is considered a predictor of major adverse cardiovascular events. The study intended to be helpful in finding methods for the preliminary assessment of PWV in primary care units. Materials and Methods: The study group consisted of 36 subjects (considered healthy by their own statement) from the medical field (medicine students and residents) aged between 20 and 30 years: 33.3% males and 66.7% females. Two types of measurements were carried out successively: (a) measurements with the arteriograph and (b) measurements on a treadmill effort testing system, where heart rate (HR) was measured over time as a response to step function physical effort (PE). Results: The study allowed for the highlighting of some limits which, if exceeded, can be associated with high PWV values: (i) if after a moderate PE and a resting time of at least 6 min, the HR is larger than 80 b/min; (ii) if the relaxation time in a PE test of moderate intensity is larger than 1 min; (iii) if the HR measured after the subject is raised from the supine to orthostatic position is larger than 100 b/min, and (iv) if the resting HR is larger than 80 b/min. Conclusions: Steady-state HR correlates with PWV and may be used for the preliminary assessment of PWV. MDPI 2022-11-12 /pmc/articles/PMC9693976/ /pubmed/36422172 http://dx.doi.org/10.3390/medicina58111633 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Marin, Ioana
Popescu, Florina Georgeta
Pauncu, Elena-Ana
Apostol, Adrian
Ivan, Viviana Mihaela
Marin, Catalin Nicolae
Fira-Mladinescu, Ovidiu
Ursoniu, Sorin
A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title_full A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title_fullStr A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title_full_unstemmed A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title_short A Heart Rate Step Function Response Method for the Evaluation of Pulse Wave Velocity as a Predictor of Major Adverse Cardio-Vascular Events
title_sort heart rate step function response method for the evaluation of pulse wave velocity as a predictor of major adverse cardio-vascular events
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9693976/
https://www.ncbi.nlm.nih.gov/pubmed/36422172
http://dx.doi.org/10.3390/medicina58111633
work_keys_str_mv AT marinioana aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT popescuflorinageorgeta aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT pauncuelenaana aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT apostoladrian aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT ivanvivianamihaela aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT marincatalinnicolae aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT firamladinescuovidiu aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT ursoniusorin aheartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT marinioana heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT popescuflorinageorgeta heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT pauncuelenaana heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT apostoladrian heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT ivanvivianamihaela heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT marincatalinnicolae heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT firamladinescuovidiu heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents
AT ursoniusorin heartratestepfunctionresponsemethodfortheevaluationofpulsewavevelocityasapredictorofmajoradversecardiovascularevents