Cargando…

Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor

We have demonstrated the use of a flat multi-wavelength Brillouin erbium-doped fiber laser (MWBEFL) based on a Sagnac loop with an unpumped erbium-doped fiber (Un-EDF) as a high-sensitivity sensor. A Sagnac loop with a Un-EDF was used as power equalizer to achieve multi-wavelength power flatness by...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Liang, He, Jian, Liu, Yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9694709/
https://www.ncbi.nlm.nih.gov/pubmed/36433610
http://dx.doi.org/10.3390/s22229017
_version_ 1784837871459368960
author Chen, Liang
He, Jian
Liu, Yi
author_facet Chen, Liang
He, Jian
Liu, Yi
author_sort Chen, Liang
collection PubMed
description We have demonstrated the use of a flat multi-wavelength Brillouin erbium-doped fiber laser (MWBEFL) based on a Sagnac loop with an unpumped erbium-doped fiber (Un-EDF) as a high-sensitivity sensor. A Sagnac loop with a Un-EDF was used as power equalizer to achieve multi-wavelength power flatness by adjusting the birefringence beat length properly. In the experiments, the best result obtained in terms of Brillouin Stokes lines and output power flatness was ±0.315 dB and the optical signal-to-noise ratio (OSNR) was 18.97 dB within a 33 nm bandwidth range from 1532.0 nm to 1565.0 nm. The flatness of the 33 nm bandwidth range varied from ±0.315 dB to ±1.38 dB and the average OSNR was about 17.51 dB. The peak power values of Brillouin Stokes lines observed under different wavelengths were extremely close and their range of fluctuation was about ±0.37 dB. These experimental results were close to our previous experimental values obtained using a passive Sagnac loop with a Un-EDF. The flat range covering almost the entire C-band has broad application prospects in high-sensitivity distributed optical fiber sensing and wavelength-division multiplexing.
format Online
Article
Text
id pubmed-9694709
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96947092022-11-26 Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor Chen, Liang He, Jian Liu, Yi Sensors (Basel) Article We have demonstrated the use of a flat multi-wavelength Brillouin erbium-doped fiber laser (MWBEFL) based on a Sagnac loop with an unpumped erbium-doped fiber (Un-EDF) as a high-sensitivity sensor. A Sagnac loop with a Un-EDF was used as power equalizer to achieve multi-wavelength power flatness by adjusting the birefringence beat length properly. In the experiments, the best result obtained in terms of Brillouin Stokes lines and output power flatness was ±0.315 dB and the optical signal-to-noise ratio (OSNR) was 18.97 dB within a 33 nm bandwidth range from 1532.0 nm to 1565.0 nm. The flatness of the 33 nm bandwidth range varied from ±0.315 dB to ±1.38 dB and the average OSNR was about 17.51 dB. The peak power values of Brillouin Stokes lines observed under different wavelengths were extremely close and their range of fluctuation was about ±0.37 dB. These experimental results were close to our previous experimental values obtained using a passive Sagnac loop with a Un-EDF. The flat range covering almost the entire C-band has broad application prospects in high-sensitivity distributed optical fiber sensing and wavelength-division multiplexing. MDPI 2022-11-21 /pmc/articles/PMC9694709/ /pubmed/36433610 http://dx.doi.org/10.3390/s22229017 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Liang
He, Jian
Liu, Yi
Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title_full Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title_fullStr Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title_full_unstemmed Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title_short Flat Multi-Wavelength Brillouin Erbium-Doped Fiber Laser Based on a Sagnac Loop for High-Sensitivity Sensor
title_sort flat multi-wavelength brillouin erbium-doped fiber laser based on a sagnac loop for high-sensitivity sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9694709/
https://www.ncbi.nlm.nih.gov/pubmed/36433610
http://dx.doi.org/10.3390/s22229017
work_keys_str_mv AT chenliang flatmultiwavelengthbrillouinerbiumdopedfiberlaserbasedonasagnacloopforhighsensitivitysensor
AT hejian flatmultiwavelengthbrillouinerbiumdopedfiberlaserbasedonasagnacloopforhighsensitivitysensor
AT liuyi flatmultiwavelengthbrillouinerbiumdopedfiberlaserbasedonasagnacloopforhighsensitivitysensor