Cargando…

A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor

A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer (MIP) is presented. The sensing device is based on a stub resonator to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the sele...

Descripción completa

Detalles Bibliográficos
Autores principales: Omidvar, Amir Hossein, Amanati Shahri, Atena, Serrano, Ariana Lacorte Caniato, Gruber, Jonas, Pamplona Rehder, Gustavo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9694762/
https://www.ncbi.nlm.nih.gov/pubmed/36433245
http://dx.doi.org/10.3390/s22228648
_version_ 1784837886366973952
author Omidvar, Amir Hossein
Amanati Shahri, Atena
Serrano, Ariana Lacorte Caniato
Gruber, Jonas
Pamplona Rehder, Gustavo
author_facet Omidvar, Amir Hossein
Amanati Shahri, Atena
Serrano, Ariana Lacorte Caniato
Gruber, Jonas
Pamplona Rehder, Gustavo
author_sort Omidvar, Amir Hossein
collection PubMed
description A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer (MIP) is presented. The sensing device is based on a stub resonator to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the selectivity of the sensor and hence the sensitivity compared to the uncoated or to the coated with non-imprinted polymer (NIP) sensor. The sensor was fabricated on a FR4 substrate for low-cost purposes. In the presence of the MIP, the sensor loaded with a glucose solution ranging from 50 mg/dL to 400 mg/dL is observed to experience an absorption frequency shift of 73 MHz when the solutions flow in a microfluidic channel passing sensing area, while the lower limit of detection (LLD) of the sensor is discovered to be 2.4 ng/dL. The experimental results show a high sensitivity of 1.3 MHz/(mg/dL) in terms of absorption frequency.
format Online
Article
Text
id pubmed-9694762
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96947622022-11-26 A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor Omidvar, Amir Hossein Amanati Shahri, Atena Serrano, Ariana Lacorte Caniato Gruber, Jonas Pamplona Rehder, Gustavo Sensors (Basel) Article A novel, low-cost, sensitive microwave microfluidic glucose detecting biosensor incorporating molecularly imprinted polymer (MIP) is presented. The sensing device is based on a stub resonator to characterize water glucose solutions. The tip of one of the stubs is coated with MIP to increase the selectivity of the sensor and hence the sensitivity compared to the uncoated or to the coated with non-imprinted polymer (NIP) sensor. The sensor was fabricated on a FR4 substrate for low-cost purposes. In the presence of the MIP, the sensor loaded with a glucose solution ranging from 50 mg/dL to 400 mg/dL is observed to experience an absorption frequency shift of 73 MHz when the solutions flow in a microfluidic channel passing sensing area, while the lower limit of detection (LLD) of the sensor is discovered to be 2.4 ng/dL. The experimental results show a high sensitivity of 1.3 MHz/(mg/dL) in terms of absorption frequency. MDPI 2022-11-09 /pmc/articles/PMC9694762/ /pubmed/36433245 http://dx.doi.org/10.3390/s22228648 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Omidvar, Amir Hossein
Amanati Shahri, Atena
Serrano, Ariana Lacorte Caniato
Gruber, Jonas
Pamplona Rehder, Gustavo
A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title_full A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title_fullStr A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title_full_unstemmed A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title_short A Highly Sensitive Molecularly Imprinted Polymer (MIP)-Coated Microwave Glucose Sensor
title_sort highly sensitive molecularly imprinted polymer (mip)-coated microwave glucose sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9694762/
https://www.ncbi.nlm.nih.gov/pubmed/36433245
http://dx.doi.org/10.3390/s22228648
work_keys_str_mv AT omidvaramirhossein ahighlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT amanatishahriatena ahighlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT serranoarianalacortecaniato ahighlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT gruberjonas ahighlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT pamplonarehdergustavo ahighlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT omidvaramirhossein highlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT amanatishahriatena highlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT serranoarianalacortecaniato highlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT gruberjonas highlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor
AT pamplonarehdergustavo highlysensitivemolecularlyimprintedpolymermipcoatedmicrowaveglucosesensor