Cargando…

Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors

The structural properties of phosphor materials, such as their grain size distribution (GSD), affect their overall optical emission performance. In the widely used gadolinium oxysulfide (Gd(2)O(2)S) host material, the type of activator is one significant parameter that also changes the GSD of the po...

Descripción completa

Detalles Bibliográficos
Autores principales: Liaparinos, Panagiotis, Michail, Christos, Valais, Ioannis, Fountos, George, Karabotsos, Athanasios, Kandarakis, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9695128/
https://www.ncbi.nlm.nih.gov/pubmed/36433300
http://dx.doi.org/10.3390/s22228702
_version_ 1784837978158268416
author Liaparinos, Panagiotis
Michail, Christos
Valais, Ioannis
Fountos, George
Karabotsos, Athanasios
Kandarakis, Ioannis
author_facet Liaparinos, Panagiotis
Michail, Christos
Valais, Ioannis
Fountos, George
Karabotsos, Athanasios
Kandarakis, Ioannis
author_sort Liaparinos, Panagiotis
collection PubMed
description The structural properties of phosphor materials, such as their grain size distribution (GSD), affect their overall optical emission performance. In the widely used gadolinium oxysulfide (Gd(2)O(2)S) host material, the type of activator is one significant parameter that also changes the GSD of the powder phosphor. For this reason, in this study, different phosphors samples of Gd(2)O(2)S:Tb, Gd(2)O(2)S:Eu, and Gd(2)O(2)S:Pr,Ce,F, were analyzed, their GSDs were experimentally determined using the scanning electron microscopy (SEM) technique, and thereafter, their optical emission profiles were investigated using the LIGHTAWE Monte Carlo simulation package. Two sets of GSDs were examined corresponding to approximately equal mean particle size, such as: (i) 1.232 μm, 1.769 μm and 1.784 μm, and (ii) 2.377 μm, 3.644 μm and 3.677 μm, for Tb, Eu and Pr,Ce,F, respectively. The results showed that light absorption was almost similar, for instance, 25.45% and 8.17% for both cases of Eu dopant utilizing a thin layer (100 μm), however, given a thicker layer (200 μm), the difference was more obvious, 22.82%. On the other hand, a high amount of light loss within the phosphor affects the laterally directed light quanta, which lead to sharper distributions and therefore to higher resolution properties of the samples.
format Online
Article
Text
id pubmed-9695128
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96951282022-11-26 Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors Liaparinos, Panagiotis Michail, Christos Valais, Ioannis Fountos, George Karabotsos, Athanasios Kandarakis, Ioannis Sensors (Basel) Article The structural properties of phosphor materials, such as their grain size distribution (GSD), affect their overall optical emission performance. In the widely used gadolinium oxysulfide (Gd(2)O(2)S) host material, the type of activator is one significant parameter that also changes the GSD of the powder phosphor. For this reason, in this study, different phosphors samples of Gd(2)O(2)S:Tb, Gd(2)O(2)S:Eu, and Gd(2)O(2)S:Pr,Ce,F, were analyzed, their GSDs were experimentally determined using the scanning electron microscopy (SEM) technique, and thereafter, their optical emission profiles were investigated using the LIGHTAWE Monte Carlo simulation package. Two sets of GSDs were examined corresponding to approximately equal mean particle size, such as: (i) 1.232 μm, 1.769 μm and 1.784 μm, and (ii) 2.377 μm, 3.644 μm and 3.677 μm, for Tb, Eu and Pr,Ce,F, respectively. The results showed that light absorption was almost similar, for instance, 25.45% and 8.17% for both cases of Eu dopant utilizing a thin layer (100 μm), however, given a thicker layer (200 μm), the difference was more obvious, 22.82%. On the other hand, a high amount of light loss within the phosphor affects the laterally directed light quanta, which lead to sharper distributions and therefore to higher resolution properties of the samples. MDPI 2022-11-11 /pmc/articles/PMC9695128/ /pubmed/36433300 http://dx.doi.org/10.3390/s22228702 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liaparinos, Panagiotis
Michail, Christos
Valais, Ioannis
Fountos, George
Karabotsos, Athanasios
Kandarakis, Ioannis
Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title_full Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title_fullStr Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title_full_unstemmed Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title_short Grain Size Distribution Analysis of Different Activator Doped Gd(2)O(2)S Powder Phosphors for Use in Medical Image Sensors
title_sort grain size distribution analysis of different activator doped gd(2)o(2)s powder phosphors for use in medical image sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9695128/
https://www.ncbi.nlm.nih.gov/pubmed/36433300
http://dx.doi.org/10.3390/s22228702
work_keys_str_mv AT liaparinospanagiotis grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors
AT michailchristos grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors
AT valaisioannis grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors
AT fountosgeorge grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors
AT karabotsosathanasios grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors
AT kandarakisioannis grainsizedistributionanalysisofdifferentactivatordopedgd2o2spowderphosphorsforuseinmedicalimagesensors