Cargando…
Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography
Electrical impedance tomography (EIT) is a non-invasive detection technology that uses the electrical response value at the boundary of an observation field to image the conductivity changes in an area. When EIT is applied to the thoracic cavity of the human body, the conductivity change caused by t...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696084/ https://www.ncbi.nlm.nih.gov/pubmed/36433295 http://dx.doi.org/10.3390/s22228698 |
_version_ | 1784838228874887168 |
---|---|
author | Zhang, Chenke Wang, Yu Ren, Shangjie Dong, Feng |
author_facet | Zhang, Chenke Wang, Yu Ren, Shangjie Dong, Feng |
author_sort | Zhang, Chenke |
collection | PubMed |
description | Electrical impedance tomography (EIT) is a non-invasive detection technology that uses the electrical response value at the boundary of an observation field to image the conductivity changes in an area. When EIT is applied to the thoracic cavity of the human body, the conductivity change caused by the heartbeat will be concentrated in a sub-region of the thoracic cavity, that is, the heart region. In order to improve the spatial resolution of the target region, two sensor optimization methods based on conformal mapping theory were proposed in this study. The effectiveness of the proposed method was verified by simulation and phantom experiment. The qualitative analysis and quantitative index evaluation of the reconstructed image showed that the optimized model could achieve higher imaging accuracy of the heart region compared with the standard sensor. The reconstruction results could effectively reflect the periodic diastolic and systolic movements of the heart and had a better ability to recognize the position of the heart in the thoracic cavity. |
format | Online Article Text |
id | pubmed-9696084 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96960842022-11-26 Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography Zhang, Chenke Wang, Yu Ren, Shangjie Dong, Feng Sensors (Basel) Article Electrical impedance tomography (EIT) is a non-invasive detection technology that uses the electrical response value at the boundary of an observation field to image the conductivity changes in an area. When EIT is applied to the thoracic cavity of the human body, the conductivity change caused by the heartbeat will be concentrated in a sub-region of the thoracic cavity, that is, the heart region. In order to improve the spatial resolution of the target region, two sensor optimization methods based on conformal mapping theory were proposed in this study. The effectiveness of the proposed method was verified by simulation and phantom experiment. The qualitative analysis and quantitative index evaluation of the reconstructed image showed that the optimized model could achieve higher imaging accuracy of the heart region compared with the standard sensor. The reconstruction results could effectively reflect the periodic diastolic and systolic movements of the heart and had a better ability to recognize the position of the heart in the thoracic cavity. MDPI 2022-11-10 /pmc/articles/PMC9696084/ /pubmed/36433295 http://dx.doi.org/10.3390/s22228698 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Chenke Wang, Yu Ren, Shangjie Dong, Feng Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title | Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title_full | Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title_fullStr | Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title_full_unstemmed | Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title_short | Case-Specific Focal Sensor Design for Cardiac Electrical Impedance Tomography |
title_sort | case-specific focal sensor design for cardiac electrical impedance tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696084/ https://www.ncbi.nlm.nih.gov/pubmed/36433295 http://dx.doi.org/10.3390/s22228698 |
work_keys_str_mv | AT zhangchenke casespecificfocalsensordesignforcardiacelectricalimpedancetomography AT wangyu casespecificfocalsensordesignforcardiacelectricalimpedancetomography AT renshangjie casespecificfocalsensordesignforcardiacelectricalimpedancetomography AT dongfeng casespecificfocalsensordesignforcardiacelectricalimpedancetomography |