Cargando…
A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696407/ https://www.ncbi.nlm.nih.gov/pubmed/36433093 http://dx.doi.org/10.3390/polym14224966 |
_version_ | 1784838309840683008 |
---|---|
author | Lee, Cheng-Ling Ma, Chao-Tsung Yeh, Kuei-Chun Chen, Yu-Ming |
author_facet | Lee, Cheng-Ling Ma, Chao-Tsung Yeh, Kuei-Chun Chen, Yu-Ming |
author_sort | Lee, Cheng-Ling |
collection | PubMed |
description | This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (length, L) and refractive index (RI, n) are highly dependent on the thermal effect. When the optical length of the polymer cavity changes with T, it is difficult to distinguish whether there is a change in L or n, or both. The variation rates of L and n with a change in T were the TOC and TEC, respectively. Therefore, there was a cross-sensitivity between TOC and TEC in the polymer-based interferometer. The proposed DCFFPI, which cascades a polymer and an air cavity, can solve the above problem. The expansion of the polymer cavity is equal to the compression of the air cavity with the increase in T. By analyzing the individual optical spectra of the polymer and air cavities, the parameters of TOC and TEC can be determined at the same time. The simultaneous measurement of TOC and TEC with small measured deviations of 6 × 10(−6) (°C(−1)) and 3.67 × 10(−5) (°C(−1)) for the polymer NOA61 and 7 × 10(−6) (°C(−1)) and 1.46 × 10(−4) (°C(−1)) for the NOA65 can be achieved. Experimental results regarding the measured accuracy for the class of adhesive-based polymer are presented to demonstrate the feasibility and verify the usefulness of the proposed DCFFPI. |
format | Online Article Text |
id | pubmed-9696407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96964072022-11-26 A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer Lee, Cheng-Ling Ma, Chao-Tsung Yeh, Kuei-Chun Chen, Yu-Ming Polymers (Basel) Article This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (length, L) and refractive index (RI, n) are highly dependent on the thermal effect. When the optical length of the polymer cavity changes with T, it is difficult to distinguish whether there is a change in L or n, or both. The variation rates of L and n with a change in T were the TOC and TEC, respectively. Therefore, there was a cross-sensitivity between TOC and TEC in the polymer-based interferometer. The proposed DCFFPI, which cascades a polymer and an air cavity, can solve the above problem. The expansion of the polymer cavity is equal to the compression of the air cavity with the increase in T. By analyzing the individual optical spectra of the polymer and air cavities, the parameters of TOC and TEC can be determined at the same time. The simultaneous measurement of TOC and TEC with small measured deviations of 6 × 10(−6) (°C(−1)) and 3.67 × 10(−5) (°C(−1)) for the polymer NOA61 and 7 × 10(−6) (°C(−1)) and 1.46 × 10(−4) (°C(−1)) for the NOA65 can be achieved. Experimental results regarding the measured accuracy for the class of adhesive-based polymer are presented to demonstrate the feasibility and verify the usefulness of the proposed DCFFPI. MDPI 2022-11-16 /pmc/articles/PMC9696407/ /pubmed/36433093 http://dx.doi.org/10.3390/polym14224966 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, Cheng-Ling Ma, Chao-Tsung Yeh, Kuei-Chun Chen, Yu-Ming A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title | A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title_full | A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title_fullStr | A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title_full_unstemmed | A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title_short | A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer |
title_sort | dual-cavity fiber fabry–pérot interferometer for simultaneous measurement of thermo-optic and thermal expansion coefficients of a polymer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696407/ https://www.ncbi.nlm.nih.gov/pubmed/36433093 http://dx.doi.org/10.3390/polym14224966 |
work_keys_str_mv | AT leechengling adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT machaotsung adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT yehkueichun adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT chenyuming adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT leechengling dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT machaotsung dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT yehkueichun dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer AT chenyuming dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer |