Cargando…

A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer

This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Cheng-Ling, Ma, Chao-Tsung, Yeh, Kuei-Chun, Chen, Yu-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696407/
https://www.ncbi.nlm.nih.gov/pubmed/36433093
http://dx.doi.org/10.3390/polym14224966
_version_ 1784838309840683008
author Lee, Cheng-Ling
Ma, Chao-Tsung
Yeh, Kuei-Chun
Chen, Yu-Ming
author_facet Lee, Cheng-Ling
Ma, Chao-Tsung
Yeh, Kuei-Chun
Chen, Yu-Ming
author_sort Lee, Cheng-Ling
collection PubMed
description This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (length, L) and refractive index (RI, n) are highly dependent on the thermal effect. When the optical length of the polymer cavity changes with T, it is difficult to distinguish whether there is a change in L or n, or both. The variation rates of L and n with a change in T were the TOC and TEC, respectively. Therefore, there was a cross-sensitivity between TOC and TEC in the polymer-based interferometer. The proposed DCFFPI, which cascades a polymer and an air cavity, can solve the above problem. The expansion of the polymer cavity is equal to the compression of the air cavity with the increase in T. By analyzing the individual optical spectra of the polymer and air cavities, the parameters of TOC and TEC can be determined at the same time. The simultaneous measurement of TOC and TEC with small measured deviations of 6 × 10(−6) (°C(−1)) and 3.67 × 10(−5) (°C(−1)) for the polymer NOA61 and 7 × 10(−6) (°C(−1)) and 1.46 × 10(−4) (°C(−1)) for the NOA65 can be achieved. Experimental results regarding the measured accuracy for the class of adhesive-based polymer are presented to demonstrate the feasibility and verify the usefulness of the proposed DCFFPI.
format Online
Article
Text
id pubmed-9696407
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96964072022-11-26 A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer Lee, Cheng-Ling Ma, Chao-Tsung Yeh, Kuei-Chun Chen, Yu-Ming Polymers (Basel) Article This paper presents a novel method based on a dual-cavity fiber Fabry–Pérot interferometer (DCFFPI) for simultaneously measuring the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) of a polymer. The polymer is, by nature, highly responsive to temperature (T) in that its size (length, L) and refractive index (RI, n) are highly dependent on the thermal effect. When the optical length of the polymer cavity changes with T, it is difficult to distinguish whether there is a change in L or n, or both. The variation rates of L and n with a change in T were the TOC and TEC, respectively. Therefore, there was a cross-sensitivity between TOC and TEC in the polymer-based interferometer. The proposed DCFFPI, which cascades a polymer and an air cavity, can solve the above problem. The expansion of the polymer cavity is equal to the compression of the air cavity with the increase in T. By analyzing the individual optical spectra of the polymer and air cavities, the parameters of TOC and TEC can be determined at the same time. The simultaneous measurement of TOC and TEC with small measured deviations of 6 × 10(−6) (°C(−1)) and 3.67 × 10(−5) (°C(−1)) for the polymer NOA61 and 7 × 10(−6) (°C(−1)) and 1.46 × 10(−4) (°C(−1)) for the NOA65 can be achieved. Experimental results regarding the measured accuracy for the class of adhesive-based polymer are presented to demonstrate the feasibility and verify the usefulness of the proposed DCFFPI. MDPI 2022-11-16 /pmc/articles/PMC9696407/ /pubmed/36433093 http://dx.doi.org/10.3390/polym14224966 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Cheng-Ling
Ma, Chao-Tsung
Yeh, Kuei-Chun
Chen, Yu-Ming
A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title_full A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title_fullStr A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title_full_unstemmed A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title_short A Dual-Cavity Fiber Fabry–Pérot Interferometer for Simultaneous Measurement of Thermo-Optic and Thermal Expansion Coefficients of a Polymer
title_sort dual-cavity fiber fabry–pérot interferometer for simultaneous measurement of thermo-optic and thermal expansion coefficients of a polymer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696407/
https://www.ncbi.nlm.nih.gov/pubmed/36433093
http://dx.doi.org/10.3390/polym14224966
work_keys_str_mv AT leechengling adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT machaotsung adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT yehkueichun adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT chenyuming adualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT leechengling dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT machaotsung dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT yehkueichun dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer
AT chenyuming dualcavityfiberfabryperotinterferometerforsimultaneousmeasurementofthermoopticandthermalexpansioncoefficientsofapolymer