Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces

The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-s...

Descripción completa

Detalles Bibliográficos
Autores principales: Kvam, Erik, Davis, Brian, Benner, Kevin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696731/
https://www.ncbi.nlm.nih.gov/pubmed/36362902
http://dx.doi.org/10.3390/life12111747
_version_ 1784838383444426752
author Kvam, Erik
Davis, Brian
Benner, Kevin
author_facet Kvam, Erik
Davis, Brian
Benner, Kevin
author_sort Kvam, Erik
collection PubMed
description The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-space continuous disinfection UV-A products. Representative organisms evaluated in this study included human-infectious enveloped and non-enveloped viruses (lentivirus and adeno-associated virus, respectively), a bacterial endospore (Bacillus atrophaeus), and a resilient gram-positive bacterium (Enterococcus faecalis). Nominal UV-A irradiances were tested at or below the UL standard limit for continuous human exposure (maximum irradiance of 10 W/m(2)). We observed photoinactivation properties that varied by organism type, with bacteria and enveloped virus being more susceptible to UV-A than non-enveloped virus and spores. Overall, we conclude that continuous-mode UV-A lighting is better suited for occupied-space disinfection than pulsing UV-A at equivalent low irradiances, and we draw comparisons to other studies in the literature.
format Online
Article
Text
id pubmed-9696731
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96967312022-11-26 Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces Kvam, Erik Davis, Brian Benner, Kevin Life (Basel) Article The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-space continuous disinfection UV-A products. Representative organisms evaluated in this study included human-infectious enveloped and non-enveloped viruses (lentivirus and adeno-associated virus, respectively), a bacterial endospore (Bacillus atrophaeus), and a resilient gram-positive bacterium (Enterococcus faecalis). Nominal UV-A irradiances were tested at or below the UL standard limit for continuous human exposure (maximum irradiance of 10 W/m(2)). We observed photoinactivation properties that varied by organism type, with bacteria and enveloped virus being more susceptible to UV-A than non-enveloped virus and spores. Overall, we conclude that continuous-mode UV-A lighting is better suited for occupied-space disinfection than pulsing UV-A at equivalent low irradiances, and we draw comparisons to other studies in the literature. MDPI 2022-10-31 /pmc/articles/PMC9696731/ /pubmed/36362902 http://dx.doi.org/10.3390/life12111747 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kvam, Erik
Davis, Brian
Benner, Kevin
Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title_full Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title_fullStr Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title_full_unstemmed Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title_short Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
title_sort comparative assessment of pulsed and continuous led uv-a lighting for disinfection of contaminated surfaces
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696731/
https://www.ncbi.nlm.nih.gov/pubmed/36362902
http://dx.doi.org/10.3390/life12111747
work_keys_str_mv AT kvamerik comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces
AT davisbrian comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces
AT bennerkevin comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces