Cargando…
Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces
The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-s...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696731/ https://www.ncbi.nlm.nih.gov/pubmed/36362902 http://dx.doi.org/10.3390/life12111747 |
_version_ | 1784838383444426752 |
---|---|
author | Kvam, Erik Davis, Brian Benner, Kevin |
author_facet | Kvam, Erik Davis, Brian Benner, Kevin |
author_sort | Kvam, Erik |
collection | PubMed |
description | The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-space continuous disinfection UV-A products. Representative organisms evaluated in this study included human-infectious enveloped and non-enveloped viruses (lentivirus and adeno-associated virus, respectively), a bacterial endospore (Bacillus atrophaeus), and a resilient gram-positive bacterium (Enterococcus faecalis). Nominal UV-A irradiances were tested at or below the UL standard limit for continuous human exposure (maximum irradiance of 10 W/m(2)). We observed photoinactivation properties that varied by organism type, with bacteria and enveloped virus being more susceptible to UV-A than non-enveloped virus and spores. Overall, we conclude that continuous-mode UV-A lighting is better suited for occupied-space disinfection than pulsing UV-A at equivalent low irradiances, and we draw comparisons to other studies in the literature. |
format | Online Article Text |
id | pubmed-9696731 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96967312022-11-26 Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces Kvam, Erik Davis, Brian Benner, Kevin Life (Basel) Article The germicidal efficacy of LED UV-A lighting has scarcely been compared in continuous and pulsed modes for contaminated surfaces. Herein, we compare the disinfection properties of pulsed versus continuous lighting at equal irradiances using a 365 nm LED device that replicates the doses of occupied-space continuous disinfection UV-A products. Representative organisms evaluated in this study included human-infectious enveloped and non-enveloped viruses (lentivirus and adeno-associated virus, respectively), a bacterial endospore (Bacillus atrophaeus), and a resilient gram-positive bacterium (Enterococcus faecalis). Nominal UV-A irradiances were tested at or below the UL standard limit for continuous human exposure (maximum irradiance of 10 W/m(2)). We observed photoinactivation properties that varied by organism type, with bacteria and enveloped virus being more susceptible to UV-A than non-enveloped virus and spores. Overall, we conclude that continuous-mode UV-A lighting is better suited for occupied-space disinfection than pulsing UV-A at equivalent low irradiances, and we draw comparisons to other studies in the literature. MDPI 2022-10-31 /pmc/articles/PMC9696731/ /pubmed/36362902 http://dx.doi.org/10.3390/life12111747 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kvam, Erik Davis, Brian Benner, Kevin Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title | Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title_full | Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title_fullStr | Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title_full_unstemmed | Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title_short | Comparative Assessment of Pulsed and Continuous LED UV-A Lighting for Disinfection of Contaminated Surfaces |
title_sort | comparative assessment of pulsed and continuous led uv-a lighting for disinfection of contaminated surfaces |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696731/ https://www.ncbi.nlm.nih.gov/pubmed/36362902 http://dx.doi.org/10.3390/life12111747 |
work_keys_str_mv | AT kvamerik comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces AT davisbrian comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces AT bennerkevin comparativeassessmentofpulsedandcontinuousleduvalightingfordisinfectionofcontaminatedsurfaces |