Cargando…

Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?

We aimed to perform an anatomical evaluation of the carotid bulb using CT-angiography, implement a new reliable index for carotid stenosis quantification and to assess the accuracy of relationship between NASCET and ECST methods in a large adult population. The cross-sectional areas of the healthy c...

Descripción completa

Detalles Bibliográficos
Autores principales: Pierro, Antonio, Modugno, Pietro, Iezzi, Roberto, Cilla, Savino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9697210/
https://www.ncbi.nlm.nih.gov/pubmed/36362834
http://dx.doi.org/10.3390/life12111678
_version_ 1784838504075755520
author Pierro, Antonio
Modugno, Pietro
Iezzi, Roberto
Cilla, Savino
author_facet Pierro, Antonio
Modugno, Pietro
Iezzi, Roberto
Cilla, Savino
author_sort Pierro, Antonio
collection PubMed
description We aimed to perform an anatomical evaluation of the carotid bulb using CT-angiography, implement a new reliable index for carotid stenosis quantification and to assess the accuracy of relationship between NASCET and ECST methods in a large adult population. The cross-sectional areas of the healthy carotid at five levels were measured by two experienced radiologists. A regression analysis was performed in order to quantify the relationship between the areas of the carotid bulb at different carotid bulbar level. A new index (Regression indeX, RegX) for carotid stenosis quantification was proposed. Five different stenoses with different grade in three bulbar locations were simulated for all patients for a total of 1365 stenoses and were used for a direct comparison of the RegX, NASCET, and ECST methods. The results of this study demonstrated that the RegX index provided a consistent and accurate measure of carotid stenosis through the application of the ECST method, avoiding the limitations of NASCET method. Furthermore, our results strongly depart from the consolidated relationships between NASCET and ECST values used in clinical practice and reported in extensive medical literature. In particular, we highlighted that a major misdiagnosis in patient selection for CEA could be introduced because of the large underestimation of real stenosis degree provided by the NASCET method. A reappraisal of carotid stenosis patients’ work-up is evoked by the effectiveness of state-of-the-art noninvasive contemporary carotid imaging.
format Online
Article
Text
id pubmed-9697210
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96972102022-11-26 Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal? Pierro, Antonio Modugno, Pietro Iezzi, Roberto Cilla, Savino Life (Basel) Article We aimed to perform an anatomical evaluation of the carotid bulb using CT-angiography, implement a new reliable index for carotid stenosis quantification and to assess the accuracy of relationship between NASCET and ECST methods in a large adult population. The cross-sectional areas of the healthy carotid at five levels were measured by two experienced radiologists. A regression analysis was performed in order to quantify the relationship between the areas of the carotid bulb at different carotid bulbar level. A new index (Regression indeX, RegX) for carotid stenosis quantification was proposed. Five different stenoses with different grade in three bulbar locations were simulated for all patients for a total of 1365 stenoses and were used for a direct comparison of the RegX, NASCET, and ECST methods. The results of this study demonstrated that the RegX index provided a consistent and accurate measure of carotid stenosis through the application of the ECST method, avoiding the limitations of NASCET method. Furthermore, our results strongly depart from the consolidated relationships between NASCET and ECST values used in clinical practice and reported in extensive medical literature. In particular, we highlighted that a major misdiagnosis in patient selection for CEA could be introduced because of the large underestimation of real stenosis degree provided by the NASCET method. A reappraisal of carotid stenosis patients’ work-up is evoked by the effectiveness of state-of-the-art noninvasive contemporary carotid imaging. MDPI 2022-10-22 /pmc/articles/PMC9697210/ /pubmed/36362834 http://dx.doi.org/10.3390/life12111678 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pierro, Antonio
Modugno, Pietro
Iezzi, Roberto
Cilla, Savino
Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title_full Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title_fullStr Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title_full_unstemmed Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title_short Challenges and Pitfalls in CT-Angiography Evaluation of Carotid Bulb Stenosis: Is It Time for a Reappraisal?
title_sort challenges and pitfalls in ct-angiography evaluation of carotid bulb stenosis: is it time for a reappraisal?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9697210/
https://www.ncbi.nlm.nih.gov/pubmed/36362834
http://dx.doi.org/10.3390/life12111678
work_keys_str_mv AT pierroantonio challengesandpitfallsinctangiographyevaluationofcarotidbulbstenosisisittimeforareappraisal
AT modugnopietro challengesandpitfallsinctangiographyevaluationofcarotidbulbstenosisisittimeforareappraisal
AT iezziroberto challengesandpitfallsinctangiographyevaluationofcarotidbulbstenosisisittimeforareappraisal
AT cillasavino challengesandpitfallsinctangiographyevaluationofcarotidbulbstenosisisittimeforareappraisal