Cargando…
Effect of a Pharmacy-based Centralized Intravenous Admixture Service on the Prevalence of Medication Errors: A Before-and-After Study
Intravenous admixture preparation errors (IAPEs) may lead to patient harm. The primary aim of this study was to assess the effect of a pharmacy-based centralized intravenous admixture service (CIVAS) on IAPEs. METHODS: We conducted a before-and-after study in 3 clinical wards before CIVAS implementa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9698191/ https://www.ncbi.nlm.nih.gov/pubmed/35786788 http://dx.doi.org/10.1097/PTS.0000000000001047 |
Sumario: | Intravenous admixture preparation errors (IAPEs) may lead to patient harm. The primary aim of this study was to assess the effect of a pharmacy-based centralized intravenous admixture service (CIVAS) on IAPEs. METHODS: We conducted a before-and-after study in 3 clinical wards before CIVAS implementation and in the CIVAS unit 18 months after implementation. Intravenous admixture preparation error data were collected by disguised observation. The primary outcome was the proportion of admixtures with 1 or more IAPEs. Secondary outcomes were the type and potential severity of IAPEs, noncompliance to hygiene procedures, and nursing staff satisfaction with the CIVAS. The primary outcome was analyzed using a multivariable mixed-effects logistic regression model. RESULTS: One or more IAPEs were identified in 14 of 543 admixtures (2.6%) in the CIVAS unit and in 148 of 282 admixtures (52.5%) in the clinical wards (odds ratio, 0.02; 95% confidence interval, 0.004–0.05). The most common IAPE types were wrong solvent or diluent (n = 95) and wrong volume of infusion fluid (n = 45). No potentially harmful IAPEs occurred in the CIVAS unit as opposed to 22 (7.8%) in the clinical wards. Disinfection procedures were better adhered to in the CIVAS unit. Overall nurse satisfaction with the CIVAS increased from a median of 70 (n = 166) 5 months after intervention to 77 (n = 115) 18 months after intervention (P < 0.001) on a 100-point scale. CONCLUSIONS: Centralized intravenous admixture service performed notably better than the clinical wards with regard to IAPEs and noncompliance to hygiene procedures. Nurses were satisfied with the CIVAS. Hence, the implementation of CIVAS is an important strategy to improve medication safety in hospitals. |
---|