Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)

In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level...

Descripción completa

Detalles Bibliográficos
Autores principales: Grande, Francesco, Pozzan, Mario Cesare, Marconato, Raul, Mollica, Francesco, Catapano, Santo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699052/
https://www.ncbi.nlm.nih.gov/pubmed/36431449
http://dx.doi.org/10.3390/ma15227963
_version_ 1784838974052761600
author Grande, Francesco
Pozzan, Mario Cesare
Marconato, Raul
Mollica, Francesco
Catapano, Santo
author_facet Grande, Francesco
Pozzan, Mario Cesare
Marconato, Raul
Mollica, Francesco
Catapano, Santo
author_sort Grande, Francesco
collection PubMed
description In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point.
format Online
Article
Text
id pubmed-9699052
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96990522022-11-26 Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA) Grande, Francesco Pozzan, Mario Cesare Marconato, Raul Mollica, Francesco Catapano, Santo Materials (Basel) Article In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point. MDPI 2022-11-10 /pmc/articles/PMC9699052/ /pubmed/36431449 http://dx.doi.org/10.3390/ma15227963 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Grande, Francesco
Pozzan, Mario Cesare
Marconato, Raul
Mollica, Francesco
Catapano, Santo
Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title_full Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title_fullStr Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title_full_unstemmed Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title_short Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA)
title_sort evaluation of load distribution in a mandibular model with four implants depending on the number of prosthetic screws used for ot-bridge system: a finite element analysis (fea)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699052/
https://www.ncbi.nlm.nih.gov/pubmed/36431449
http://dx.doi.org/10.3390/ma15227963
work_keys_str_mv AT grandefrancesco evaluationofloaddistributioninamandibularmodelwithfourimplantsdependingonthenumberofprostheticscrewsusedforotbridgesystemafiniteelementanalysisfea
AT pozzanmariocesare evaluationofloaddistributioninamandibularmodelwithfourimplantsdependingonthenumberofprostheticscrewsusedforotbridgesystemafiniteelementanalysisfea
AT marconatoraul evaluationofloaddistributioninamandibularmodelwithfourimplantsdependingonthenumberofprostheticscrewsusedforotbridgesystemafiniteelementanalysisfea
AT mollicafrancesco evaluationofloaddistributioninamandibularmodelwithfourimplantsdependingonthenumberofprostheticscrewsusedforotbridgesystemafiniteelementanalysisfea
AT catapanosanto evaluationofloaddistributioninamandibularmodelwithfourimplantsdependingonthenumberofprostheticscrewsusedforotbridgesystemafiniteelementanalysisfea