Cargando…
Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors
The possibility of voltammetric ion sensing is demonstrated, for the first time, for ion-selective electrodes (ISEs) containing an internal aqueous solution. ISEs selective to calcium, lithium and potassium ions are used as model systems. The internal solution of the ISEs contains a chloride salt of...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699433/ https://www.ncbi.nlm.nih.gov/pubmed/36363603 http://dx.doi.org/10.3390/membranes12111048 |
_version_ | 1784839072164872192 |
---|---|
author | Keresten, Valentina Mikhelson, Konstantin |
author_facet | Keresten, Valentina Mikhelson, Konstantin |
author_sort | Keresten, Valentina |
collection | PubMed |
description | The possibility of voltammetric ion sensing is demonstrated, for the first time, for ion-selective electrodes (ISEs) containing an internal aqueous solution. ISEs selective to calcium, lithium and potassium ions are used as model systems. The internal solution of the ISEs contains a chloride salt of the respective cation and a ferrocenemethanol or ferrocyanide/ferricyanide redox couple. A platinum wire is used as the internal reference electrode. It is shown, theoretically and experimentally, that the dependence of oxidation and reduction peak potentials on the sample composition obeys the Nernst law, while the peak currents virtually do not depend on the sample composition. Thus, the electrode behavior is similar to that reported by Bakker’s group for solid contact ISEs with ultra-thin membranes (200–300 nm). It is shown that the use of classical ISEs with relatively thick membranes (100–300 µm) and internal aqueous solution allows for the sensor lifetime of about one month. It is also shown that use of a suitable background electrolyte allows for improvement of the detection limits in voltammetric measurements with ISEs. |
format | Online Article Text |
id | pubmed-9699433 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96994332022-11-26 Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors Keresten, Valentina Mikhelson, Konstantin Membranes (Basel) Article The possibility of voltammetric ion sensing is demonstrated, for the first time, for ion-selective electrodes (ISEs) containing an internal aqueous solution. ISEs selective to calcium, lithium and potassium ions are used as model systems. The internal solution of the ISEs contains a chloride salt of the respective cation and a ferrocenemethanol or ferrocyanide/ferricyanide redox couple. A platinum wire is used as the internal reference electrode. It is shown, theoretically and experimentally, that the dependence of oxidation and reduction peak potentials on the sample composition obeys the Nernst law, while the peak currents virtually do not depend on the sample composition. Thus, the electrode behavior is similar to that reported by Bakker’s group for solid contact ISEs with ultra-thin membranes (200–300 nm). It is shown that the use of classical ISEs with relatively thick membranes (100–300 µm) and internal aqueous solution allows for the sensor lifetime of about one month. It is also shown that use of a suitable background electrolyte allows for improvement of the detection limits in voltammetric measurements with ISEs. MDPI 2022-10-27 /pmc/articles/PMC9699433/ /pubmed/36363603 http://dx.doi.org/10.3390/membranes12111048 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Keresten, Valentina Mikhelson, Konstantin Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title | Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title_full | Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title_fullStr | Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title_full_unstemmed | Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title_short | Voltammetric Ion Sensing with Ionophore-Based Ion-Selective Electrodes Containing Internal Aqueous Solution, Improving Lifetime of Sensors |
title_sort | voltammetric ion sensing with ionophore-based ion-selective electrodes containing internal aqueous solution, improving lifetime of sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699433/ https://www.ncbi.nlm.nih.gov/pubmed/36363603 http://dx.doi.org/10.3390/membranes12111048 |
work_keys_str_mv | AT kerestenvalentina voltammetricionsensingwithionophorebasedionselectiveelectrodescontaininginternalaqueoussolutionimprovinglifetimeofsensors AT mikhelsonkonstantin voltammetricionsensingwithionophorebasedionselectiveelectrodescontaininginternalaqueoussolutionimprovinglifetimeofsensors |