Cargando…
Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review
BACKGROUND: Delayed aneurysm rupture after flow-redirection endoluminal device (FRED) implantation is rare. We report a case of internal carotid-cavernous fistula (CCF) caused by a delayed aneurysm rupture of the cavernous portion of the internal carotid artery (ICA) after FRED implantation. CASE DE...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientific Scholar
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699850/ https://www.ncbi.nlm.nih.gov/pubmed/36447882 http://dx.doi.org/10.25259/SNI_783_2022 |
_version_ | 1784839175939293184 |
---|---|
author | Tsukagoshi, Eisuke Sato, Hiroki Kohyama, Shinya |
author_facet | Tsukagoshi, Eisuke Sato, Hiroki Kohyama, Shinya |
author_sort | Tsukagoshi, Eisuke |
collection | PubMed |
description | BACKGROUND: Delayed aneurysm rupture after flow-redirection endoluminal device (FRED) implantation is rare. We report a case of internal carotid-cavernous fistula (CCF) caused by a delayed aneurysm rupture of the cavernous portion of the internal carotid artery (ICA) after FRED implantation. CASE DESCRIPTION: A 75-year-old woman had a gradually enlarging aneurysm at the C4 portion of the left ICA. We performed FRED implantation for the same. The FRED implantation procedure was smooth and the FRED expanded well and attached to the vessel wall. Five days after surgery, the patient developed a strong headache, hyperemia of the left eye, and disturbance of the left eye movement. Magnetic resonance imaging and angiography revealed a left CCF with cortical venous reflux. We performed transarterial aneurysmal and transvenous cavernous sinus embolization. Postoperatively, angiography showed no fistula and complete occlusion of the aneurysm; however, minor eye movement disorder persisted. CONCLUSION: To prevent the development of delayed aneurysm rupture in patients treated with FRED, preoperative consideration of whether to add coil embolization is important, even if the aneurysm is located in the C4 portion of the ICA and there is no risk of subarachnoid hemorrhage, including the size of aneurysm. In this report, we have tried to alert surgeons regarding the risk of delayed aneurysm rupture due to FRED implantation. |
format | Online Article Text |
id | pubmed-9699850 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Scientific Scholar |
record_format | MEDLINE/PubMed |
spelling | pubmed-96998502022-11-28 Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review Tsukagoshi, Eisuke Sato, Hiroki Kohyama, Shinya Surg Neurol Int Case Report BACKGROUND: Delayed aneurysm rupture after flow-redirection endoluminal device (FRED) implantation is rare. We report a case of internal carotid-cavernous fistula (CCF) caused by a delayed aneurysm rupture of the cavernous portion of the internal carotid artery (ICA) after FRED implantation. CASE DESCRIPTION: A 75-year-old woman had a gradually enlarging aneurysm at the C4 portion of the left ICA. We performed FRED implantation for the same. The FRED implantation procedure was smooth and the FRED expanded well and attached to the vessel wall. Five days after surgery, the patient developed a strong headache, hyperemia of the left eye, and disturbance of the left eye movement. Magnetic resonance imaging and angiography revealed a left CCF with cortical venous reflux. We performed transarterial aneurysmal and transvenous cavernous sinus embolization. Postoperatively, angiography showed no fistula and complete occlusion of the aneurysm; however, minor eye movement disorder persisted. CONCLUSION: To prevent the development of delayed aneurysm rupture in patients treated with FRED, preoperative consideration of whether to add coil embolization is important, even if the aneurysm is located in the C4 portion of the ICA and there is no risk of subarachnoid hemorrhage, including the size of aneurysm. In this report, we have tried to alert surgeons regarding the risk of delayed aneurysm rupture due to FRED implantation. Scientific Scholar 2022-11-04 /pmc/articles/PMC9699850/ /pubmed/36447882 http://dx.doi.org/10.25259/SNI_783_2022 Text en Copyright: © 2022 Surgical Neurology International https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Tsukagoshi, Eisuke Sato, Hiroki Kohyama, Shinya Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title | Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title_full | Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title_fullStr | Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title_full_unstemmed | Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title_short | Delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: A case report and literature review |
title_sort | delayed aneurysm rupture in a patient treated with flow redirection endoluminal device: a case report and literature review |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699850/ https://www.ncbi.nlm.nih.gov/pubmed/36447882 http://dx.doi.org/10.25259/SNI_783_2022 |
work_keys_str_mv | AT tsukagoshieisuke delayedaneurysmruptureinapatienttreatedwithflowredirectionendoluminaldeviceacasereportandliteraturereview AT satohiroki delayedaneurysmruptureinapatienttreatedwithflowredirectionendoluminaldeviceacasereportandliteraturereview AT kohyamashinya delayedaneurysmruptureinapatienttreatedwithflowredirectionendoluminaldeviceacasereportandliteraturereview |