Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging

OBJECTIVES: To evaluate the accuracy of dual-energy computed tomography (DECT) in quantifying bone marrow adipose tissue (BMAT) and its applicability in the study of osteoporosis (OP). METHODS: A total of 83 patients with low back pain (59.77 ± 7.46 years, 30 males) were enrolled. All patients under...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zhenghua, Huang, Dageng, Zhang, Yuting, Chang, Rong, Zhang, Xiaoyue, Jiang, Yonghong, Ma, Xiaowen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9701266/
https://www.ncbi.nlm.nih.gov/pubmed/36435946
http://dx.doi.org/10.1186/s13244-022-01326-0
_version_ 1784839497623535616
author Liu, Zhenghua
Huang, Dageng
Zhang, Yuting
Chang, Rong
Zhang, Xiaoyue
Jiang, Yonghong
Ma, Xiaowen
author_facet Liu, Zhenghua
Huang, Dageng
Zhang, Yuting
Chang, Rong
Zhang, Xiaoyue
Jiang, Yonghong
Ma, Xiaowen
author_sort Liu, Zhenghua
collection PubMed
description OBJECTIVES: To evaluate the accuracy of dual-energy computed tomography (DECT) in quantifying bone marrow adipose tissue (BMAT) and its applicability in the study of osteoporosis (OP). METHODS: A total of 83 patients with low back pain (59.77 ± 7.46 years, 30 males) were enrolled. All patients underwent lumbar DECT and magnetic resonance imaging (MRI) scanning within 48 h, and the vertebral fat fraction (FF) was quantitatively measured, recorded as DECT-FF and MRI-FF. A standard quantitative computed tomography (QCT) phantom was positioned under the waist during DECT procedure to realize the quantization of bone mineral density (BMD). The intraclass correlation coefficient (ICC) and Bland–Altman method was used to evaluate the agreement between DECT-FF and MRI-FF. The Pearson test was used to study the correlation between DECT-FF, MRI-FF, and BMD. With BMD as a gold standard, the diagnostic efficacy of DECT-FF and MRI-FF in different OP degrees was compared by receiver operating characteristic (ROC) curve and DeLong test. RESULTS: The values of DECT-FF and MRI-FF agreed well (ICC = 0.918). DECT-FF and MRI-FF correlated with BMD, with r values of −0.660 and −0.669, respectively (p < 0.05). In the diagnosis of OP and osteopenia, the areas under curve (AUC) of DECT-FF was, respectively, 0.791 and 0.710, and that of MRI-FF was 0.807 and 0.708, and there was no significant difference between AUCs of two FF values (with Z values of 0.503 and 0.066, all p > 0.05). CONCLUSION: DECT can accurately quantify the BMAT of vertebrae and has the same applicability as MRI in the study of OP.
format Online
Article
Text
id pubmed-9701266
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-97012662022-11-28 Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging Liu, Zhenghua Huang, Dageng Zhang, Yuting Chang, Rong Zhang, Xiaoyue Jiang, Yonghong Ma, Xiaowen Insights Imaging Original Article OBJECTIVES: To evaluate the accuracy of dual-energy computed tomography (DECT) in quantifying bone marrow adipose tissue (BMAT) and its applicability in the study of osteoporosis (OP). METHODS: A total of 83 patients with low back pain (59.77 ± 7.46 years, 30 males) were enrolled. All patients underwent lumbar DECT and magnetic resonance imaging (MRI) scanning within 48 h, and the vertebral fat fraction (FF) was quantitatively measured, recorded as DECT-FF and MRI-FF. A standard quantitative computed tomography (QCT) phantom was positioned under the waist during DECT procedure to realize the quantization of bone mineral density (BMD). The intraclass correlation coefficient (ICC) and Bland–Altman method was used to evaluate the agreement between DECT-FF and MRI-FF. The Pearson test was used to study the correlation between DECT-FF, MRI-FF, and BMD. With BMD as a gold standard, the diagnostic efficacy of DECT-FF and MRI-FF in different OP degrees was compared by receiver operating characteristic (ROC) curve and DeLong test. RESULTS: The values of DECT-FF and MRI-FF agreed well (ICC = 0.918). DECT-FF and MRI-FF correlated with BMD, with r values of −0.660 and −0.669, respectively (p < 0.05). In the diagnosis of OP and osteopenia, the areas under curve (AUC) of DECT-FF was, respectively, 0.791 and 0.710, and that of MRI-FF was 0.807 and 0.708, and there was no significant difference between AUCs of two FF values (with Z values of 0.503 and 0.066, all p > 0.05). CONCLUSION: DECT can accurately quantify the BMAT of vertebrae and has the same applicability as MRI in the study of OP. Springer Vienna 2022-11-26 /pmc/articles/PMC9701266/ /pubmed/36435946 http://dx.doi.org/10.1186/s13244-022-01326-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Liu, Zhenghua
Huang, Dageng
Zhang, Yuting
Chang, Rong
Zhang, Xiaoyue
Jiang, Yonghong
Ma, Xiaowen
Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title_full Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title_fullStr Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title_full_unstemmed Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title_short Accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
title_sort accuracy and applicability of dual-energy computed tomography in quantifying vertebral bone marrow adipose tissue compared with magnetic resonance imaging
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9701266/
https://www.ncbi.nlm.nih.gov/pubmed/36435946
http://dx.doi.org/10.1186/s13244-022-01326-0
work_keys_str_mv AT liuzhenghua accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT huangdageng accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT zhangyuting accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT changrong accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT zhangxiaoyue accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT jiangyonghong accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging
AT maxiaowen accuracyandapplicabilityofdualenergycomputedtomographyinquantifyingvertebralbonemarrowadiposetissuecomparedwithmagneticresonanceimaging