Cargando…

Evaluation of lung ultrasound to detect volume overload in children undergoing dialysis

BACKGROUND: Lung ultrasound is a well-established technique to assess extravascular lung water, a proxy for volume status, in the adult population. Despite its utility, the data are limited supporting the use of ultrasound to evaluate fluid volume status among pediatric patients. Our study uses a si...

Descripción completa

Detalles Bibliográficos
Autores principales: Arthur, Lindsay, Prodhan, Parthak, Blaszak, Richard, Crawford, Brendan, Brown, Clare C., Arthur, Jason
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9702747/
https://www.ncbi.nlm.nih.gov/pubmed/36434355
http://dx.doi.org/10.1007/s00467-022-05723-x
Descripción
Sumario:BACKGROUND: Lung ultrasound is a well-established technique to assess extravascular lung water, a proxy for volume status, in the adult population. Despite its utility, the data are limited supporting the use of ultrasound to evaluate fluid volume status among pediatric patients. Our study uses a simplified ultrasound protocol to evaluate changes in extravascular lung water, represented by b-lines, among pediatric patients undergoing hemodialysis. METHODS: This prospective single-center study included children from birth to 18 years of age. The number of b-lines per ml/kg of fluid removed was compared prior to, at the midpoint, and following termination of dialysis. An 8-zone protocol was utilized, and b-lines were correlated to hemoconcentration measured by the CRIT-LINE® hematocrit. RESULTS: Six patients with a total of 26 hemodialysis sessions were included in this study. The b-line measurements post-dialysis were 2.27 (p < 0.001; 94%CI -3.31, -1.22) lower relative to pre-dialysis. The number of b-lines was reduced by 1.69 (p < 0.001; -2.58, -0.80) between pre-dialysis and at the midpoint of dialysis and by 0.58 (p = 0.001; -0.90, -0.24) between the midpoint of dialysis and post-dialysis. A 1 mL/kg fluid loss correlated to a decrease in the original b-lines by 0.079. An inverse relationship (r = -0.54; 95% CI: -0.72, -0.34; p < 0.001) was noted between the b-lines and the patients’ hematocrit levels. CONCLUSIONS: A simplified 8-zone ultrasound protocol can assess fluid volume change in real time and correlates with hematocrit levels obtained throughout dialysis. This provides a valuable method for monitoring fluid status in volume overloaded patient populations. GRAPHICAL ABSTRACT: [Figure: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00467-022-05723-x.