Cargando…

Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension

Effective communication requires good speech perception abilities. Speech perception can be assessed with behavioral and electrophysiological methods. Relating these two types of measures to each other can provide a basis for new clinical tests. In audiological practice, speech detection and discrim...

Descripción completa

Detalles Bibliográficos
Autores principales: Deshpande, Pushkar, Brandt, Christian, Debener, Stefan, Neher, Tobias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9703531/
https://www.ncbi.nlm.nih.gov/pubmed/36423251
http://dx.doi.org/10.1177/23312165221139733
_version_ 1784839874162982912
author Deshpande, Pushkar
Brandt, Christian
Debener, Stefan
Neher, Tobias
author_facet Deshpande, Pushkar
Brandt, Christian
Debener, Stefan
Neher, Tobias
author_sort Deshpande, Pushkar
collection PubMed
description Effective communication requires good speech perception abilities. Speech perception can be assessed with behavioral and electrophysiological methods. Relating these two types of measures to each other can provide a basis for new clinical tests. In audiological practice, speech detection and discrimination are routinely assessed, whereas comprehension-related aspects are ignored. The current study compared behavioral and electrophysiological measures of speech detection, discrimination, and comprehension. Thirty young normal-hearing native Danish speakers participated. All measurements were carried out with digits and stationary speech-shaped noise as the stimuli. The behavioral measures included speech detection thresholds (SDTs), speech recognition thresholds (SRTs), and speech comprehension scores (i.e., response times). For the electrophysiological measures, multichannel electroencephalography (EEG) recordings were performed. N100 and P300 responses were evoked using an active auditory oddball paradigm. N400 and Late Positive Complex (LPC) responses were evoked using a paradigm based on congruent and incongruent digit triplets, with the digits presented either all acoustically or first visually (digits 1–2) and then acoustically (digit 3). While no correlations between the SDTs and SRTs and the N100 and P300 responses were found, the response times were correlated with the EEG responses to the congruent and incongruent triplets. Furthermore, significant differences between the response times (but not EEG responses) obtained with auditory and visual-then-auditory stimulus presentation were observed. This pattern of results could reflect a faster recall mechanism when the first two digits are presented visually rather than acoustically. The visual-then-auditory condition may facilitate the assessment of comprehension-related processes in hard-of-hearing individuals.
format Online
Article
Text
id pubmed-9703531
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-97035312022-11-29 Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension Deshpande, Pushkar Brandt, Christian Debener, Stefan Neher, Tobias Trends Hear ISAAR 2021 Effective communication requires good speech perception abilities. Speech perception can be assessed with behavioral and electrophysiological methods. Relating these two types of measures to each other can provide a basis for new clinical tests. In audiological practice, speech detection and discrimination are routinely assessed, whereas comprehension-related aspects are ignored. The current study compared behavioral and electrophysiological measures of speech detection, discrimination, and comprehension. Thirty young normal-hearing native Danish speakers participated. All measurements were carried out with digits and stationary speech-shaped noise as the stimuli. The behavioral measures included speech detection thresholds (SDTs), speech recognition thresholds (SRTs), and speech comprehension scores (i.e., response times). For the electrophysiological measures, multichannel electroencephalography (EEG) recordings were performed. N100 and P300 responses were evoked using an active auditory oddball paradigm. N400 and Late Positive Complex (LPC) responses were evoked using a paradigm based on congruent and incongruent digit triplets, with the digits presented either all acoustically or first visually (digits 1–2) and then acoustically (digit 3). While no correlations between the SDTs and SRTs and the N100 and P300 responses were found, the response times were correlated with the EEG responses to the congruent and incongruent triplets. Furthermore, significant differences between the response times (but not EEG responses) obtained with auditory and visual-then-auditory stimulus presentation were observed. This pattern of results could reflect a faster recall mechanism when the first two digits are presented visually rather than acoustically. The visual-then-auditory condition may facilitate the assessment of comprehension-related processes in hard-of-hearing individuals. SAGE Publications 2022-11-24 /pmc/articles/PMC9703531/ /pubmed/36423251 http://dx.doi.org/10.1177/23312165221139733 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle ISAAR 2021
Deshpande, Pushkar
Brandt, Christian
Debener, Stefan
Neher, Tobias
Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title_full Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title_fullStr Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title_full_unstemmed Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title_short Comparing Clinically Applicable Behavioral and Electrophysiological Measures of Speech Detection, Discrimination, and Comprehension
title_sort comparing clinically applicable behavioral and electrophysiological measures of speech detection, discrimination, and comprehension
topic ISAAR 2021
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9703531/
https://www.ncbi.nlm.nih.gov/pubmed/36423251
http://dx.doi.org/10.1177/23312165221139733
work_keys_str_mv AT deshpandepushkar comparingclinicallyapplicablebehavioralandelectrophysiologicalmeasuresofspeechdetectiondiscriminationandcomprehension
AT brandtchristian comparingclinicallyapplicablebehavioralandelectrophysiologicalmeasuresofspeechdetectiondiscriminationandcomprehension
AT debenerstefan comparingclinicallyapplicablebehavioralandelectrophysiologicalmeasuresofspeechdetectiondiscriminationandcomprehension
AT nehertobias comparingclinicallyapplicablebehavioralandelectrophysiologicalmeasuresofspeechdetectiondiscriminationandcomprehension