Cargando…

Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study

Purpose One of the commonest treatment options for replacing missing teeth is a root-form implant. Clinically, the key mechanical factor in achieving success is primary stability. This ex vivo study aims to evaluate whether osseodensification method will achieve good primary stability or the convent...

Descripción completa

Detalles Bibliográficos
Autores principales: Bandela, Vinod, Shetty, Neema, Munagapati, Bharathi, Basany, Ram B, Kanaparthi, Saraswathi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704508/
https://www.ncbi.nlm.nih.gov/pubmed/36451653
http://dx.doi.org/10.7759/cureus.30843
_version_ 1784840069698289664
author Bandela, Vinod
Shetty, Neema
Munagapati, Bharathi
Basany, Ram B
Kanaparthi, Saraswathi
author_facet Bandela, Vinod
Shetty, Neema
Munagapati, Bharathi
Basany, Ram B
Kanaparthi, Saraswathi
author_sort Bandela, Vinod
collection PubMed
description Purpose One of the commonest treatment options for replacing missing teeth is a root-form implant. Clinically, the key mechanical factor in achieving success is primary stability. This ex vivo study aims to evaluate whether osseodensification method will achieve good primary stability or the conventional drilling protocol. Methods Fresh iliac bone of the sheep was selected similar to D3 and D4 bone densities. A total of 22 osteotomy sites were prepared in the bone sample, of which 11 were prepared by osseodensification method (test group) and other 11 by conventional undersized drilling (control group). Primary stability was measured using insertion torque (IT), resonance frequency analysis (RFA), and reverse torque values (RTVs) by measuring implant stability quotient (ISQ). The recorded data were statistically analyzed using Statistical Package for the Social Sciences (SPSS) Version 22.0. The differences between groups were compared using the Mann-Whitney U test and independent t-test. The Pearson correlation coefficient test was performed to measure the linear relationship between two variables. The statistical significance level was established at p<0.05. Results When the correlation among IT, RTV, and ISQ was measured, a statistically significant correlation between IT and RTV (p=0.001) and between IT and ISQ (p=0.0001) was observed. A statistically significant (p=0.014) correlation between RTV and ISQ was also found. Conclusion Osteotomy prepared by osseodensification method showed higher IT, RTV, and ISQ values than the conventional undersized group.
format Online
Article
Text
id pubmed-9704508
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-97045082022-11-29 Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study Bandela, Vinod Shetty, Neema Munagapati, Bharathi Basany, Ram B Kanaparthi, Saraswathi Cureus Dentistry Purpose One of the commonest treatment options for replacing missing teeth is a root-form implant. Clinically, the key mechanical factor in achieving success is primary stability. This ex vivo study aims to evaluate whether osseodensification method will achieve good primary stability or the conventional drilling protocol. Methods Fresh iliac bone of the sheep was selected similar to D3 and D4 bone densities. A total of 22 osteotomy sites were prepared in the bone sample, of which 11 were prepared by osseodensification method (test group) and other 11 by conventional undersized drilling (control group). Primary stability was measured using insertion torque (IT), resonance frequency analysis (RFA), and reverse torque values (RTVs) by measuring implant stability quotient (ISQ). The recorded data were statistically analyzed using Statistical Package for the Social Sciences (SPSS) Version 22.0. The differences between groups were compared using the Mann-Whitney U test and independent t-test. The Pearson correlation coefficient test was performed to measure the linear relationship between two variables. The statistical significance level was established at p<0.05. Results When the correlation among IT, RTV, and ISQ was measured, a statistically significant correlation between IT and RTV (p=0.001) and between IT and ISQ (p=0.0001) was observed. A statistically significant (p=0.014) correlation between RTV and ISQ was also found. Conclusion Osteotomy prepared by osseodensification method showed higher IT, RTV, and ISQ values than the conventional undersized group. Cureus 2022-10-29 /pmc/articles/PMC9704508/ /pubmed/36451653 http://dx.doi.org/10.7759/cureus.30843 Text en Copyright © 2022, Bandela et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Bandela, Vinod
Shetty, Neema
Munagapati, Bharathi
Basany, Ram B
Kanaparthi, Saraswathi
Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title_full Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title_fullStr Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title_full_unstemmed Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title_short Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study
title_sort comparative evaluation of osseodensification versus conventional osteotomy technique on dental implant primary stability: an ex vivo study
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704508/
https://www.ncbi.nlm.nih.gov/pubmed/36451653
http://dx.doi.org/10.7759/cureus.30843
work_keys_str_mv AT bandelavinod comparativeevaluationofosseodensificationversusconventionalosteotomytechniqueondentalimplantprimarystabilityanexvivostudy
AT shettyneema comparativeevaluationofosseodensificationversusconventionalosteotomytechniqueondentalimplantprimarystabilityanexvivostudy
AT munagapatibharathi comparativeevaluationofosseodensificationversusconventionalosteotomytechniqueondentalimplantprimarystabilityanexvivostudy
AT basanyramb comparativeevaluationofosseodensificationversusconventionalosteotomytechniqueondentalimplantprimarystabilityanexvivostudy
AT kanaparthisaraswathi comparativeevaluationofosseodensificationversusconventionalosteotomytechniqueondentalimplantprimarystabilityanexvivostudy