Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures

BACKGROUND: Percutaneous vertebroplasty (PVP) has been used widely to treat osteoporotic vertebral compression fractures (OVCFs). However, it has many disadvantages, such as excessive radiation exposure, long operation times, and high cement leakage rates. This study was conducted to explore the cli...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Jianquan, Lin, Xinyuan, Lv, Zhouming, Chen, Maoshui, Huang, Taosheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704564/
https://www.ncbi.nlm.nih.gov/pubmed/36441717
http://dx.doi.org/10.1371/journal.pone.0276930
_version_ 1784840082108186624
author Chen, Jianquan
Lin, Xinyuan
Lv, Zhouming
Chen, Maoshui
Huang, Taosheng
author_facet Chen, Jianquan
Lin, Xinyuan
Lv, Zhouming
Chen, Maoshui
Huang, Taosheng
author_sort Chen, Jianquan
collection PubMed
description BACKGROUND: Percutaneous vertebroplasty (PVP) has been used widely to treat osteoporotic vertebral compression fractures (OVCFs). However, it has many disadvantages, such as excessive radiation exposure, long operation times, and high cement leakage rates. This study was conducted to explore the clinical effects and safety of the use of a three-dimensional (3D)-printed body-surface guide plate to aid PVP for the treatment of OVCFs. METHODS: This prospective cohort study was conducted with patients with OVCFs presenting between October 2020 and June 2021. Fifty patients underwent traditional PVP (group T) and 47 patients underwent PVP aided by 3D-printed body-surface guide plates (3D group). The following clinical and adverse events were compared between groups: the puncture positioning, puncture, fluoroscopy exposure and total operation times; changes in vertebral height and the Cobb angle after surgery relative to baseline; preoperative and postoperative visual analog scale and Oswestry disability index scores; and perioperative complications (bone cement leakage, neurological impairment, vertebral infection, and cardiopulmonary complications. RESULTS: The puncture, adjustment, fluoroscopy, and total operation times were shorter in the 3D group than in group T. Visual analog scale and Oswestry disability index scores improved significantly after surgery, with significant differences between groups (both p < 0.05). At the last follow-up examination, the vertebral midline height and Cobb angle did not differ between groups. The incidence of complications was significantly lower in the 3D group than in group T (p < 0.05). CONCLUSION: The use of 3D-printed body-surface guide plates can simplify and optimize PVP, shortening the operative time, improving the success rate, reducing surgical complications, and overall improving the safety of PVP.
format Online
Article
Text
id pubmed-9704564
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97045642022-11-29 Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures Chen, Jianquan Lin, Xinyuan Lv, Zhouming Chen, Maoshui Huang, Taosheng PLoS One Research Article BACKGROUND: Percutaneous vertebroplasty (PVP) has been used widely to treat osteoporotic vertebral compression fractures (OVCFs). However, it has many disadvantages, such as excessive radiation exposure, long operation times, and high cement leakage rates. This study was conducted to explore the clinical effects and safety of the use of a three-dimensional (3D)-printed body-surface guide plate to aid PVP for the treatment of OVCFs. METHODS: This prospective cohort study was conducted with patients with OVCFs presenting between October 2020 and June 2021. Fifty patients underwent traditional PVP (group T) and 47 patients underwent PVP aided by 3D-printed body-surface guide plates (3D group). The following clinical and adverse events were compared between groups: the puncture positioning, puncture, fluoroscopy exposure and total operation times; changes in vertebral height and the Cobb angle after surgery relative to baseline; preoperative and postoperative visual analog scale and Oswestry disability index scores; and perioperative complications (bone cement leakage, neurological impairment, vertebral infection, and cardiopulmonary complications. RESULTS: The puncture, adjustment, fluoroscopy, and total operation times were shorter in the 3D group than in group T. Visual analog scale and Oswestry disability index scores improved significantly after surgery, with significant differences between groups (both p < 0.05). At the last follow-up examination, the vertebral midline height and Cobb angle did not differ between groups. The incidence of complications was significantly lower in the 3D group than in group T (p < 0.05). CONCLUSION: The use of 3D-printed body-surface guide plates can simplify and optimize PVP, shortening the operative time, improving the success rate, reducing surgical complications, and overall improving the safety of PVP. Public Library of Science 2022-11-28 /pmc/articles/PMC9704564/ /pubmed/36441717 http://dx.doi.org/10.1371/journal.pone.0276930 Text en © 2022 Chen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Chen, Jianquan
Lin, Xinyuan
Lv, Zhouming
Chen, Maoshui
Huang, Taosheng
Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title_full Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title_fullStr Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title_full_unstemmed Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title_short Use of a 3D-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
title_sort use of a 3d-printed body surface percutaneous puncture guide plate in vertebroplasty for osteoporotic vertebral compression fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704564/
https://www.ncbi.nlm.nih.gov/pubmed/36441717
http://dx.doi.org/10.1371/journal.pone.0276930
work_keys_str_mv AT chenjianquan useofa3dprintedbodysurfacepercutaneouspunctureguideplateinvertebroplastyforosteoporoticvertebralcompressionfractures
AT linxinyuan useofa3dprintedbodysurfacepercutaneouspunctureguideplateinvertebroplastyforosteoporoticvertebralcompressionfractures
AT lvzhouming useofa3dprintedbodysurfacepercutaneouspunctureguideplateinvertebroplastyforosteoporoticvertebralcompressionfractures
AT chenmaoshui useofa3dprintedbodysurfacepercutaneouspunctureguideplateinvertebroplastyforosteoporoticvertebralcompressionfractures
AT huangtaosheng useofa3dprintedbodysurfacepercutaneouspunctureguideplateinvertebroplastyforosteoporoticvertebralcompressionfractures