Cargando…

Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation

A newly developed extended-depth-of-focus AcrySof(®) Vivity™ intraocular lens (IOL), which has a wavefront-shaped anterior surface, has shown a promising outcome in minimizing dysphotopsia, the biggest issue after diffractive type IOL implantation. On the contrary, relatively low uncorrected near vi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeon, Sohee, Choi, Ayoung, Kwon, Hyunggoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704673/
https://www.ncbi.nlm.nih.gov/pubmed/36441780
http://dx.doi.org/10.1371/journal.pone.0277687
_version_ 1784840104372600832
author Jeon, Sohee
Choi, Ayoung
Kwon, Hyunggoo
author_facet Jeon, Sohee
Choi, Ayoung
Kwon, Hyunggoo
author_sort Jeon, Sohee
collection PubMed
description A newly developed extended-depth-of-focus AcrySof(®) Vivity™ intraocular lens (IOL), which has a wavefront-shaped anterior surface, has shown a promising outcome in minimizing dysphotopsia, the biggest issue after diffractive type IOL implantation. On the contrary, relatively low uncorrected near visual acuity (UNVA) has been raised as a demerit of this IOL. However, there is only limited information about the UNVA after Vivity implantation. In the present study, we compared the uncorrected distant and intermediate visual acuity (UDVA and UIVA) and UNVA according to the range of refractive error (RE) from 91 eyes from 91 patients implanted with Vivity IOL. Then we assessed the biometric factors for their association with UNVA from 66 eyes with a RE within ± 0.25 D. The UDVA was worst in eyes with RE < -0.50 D (0.17 ± 0.21), which was significantly worse than in any other group (P < 0.001 for every analysis). The UIVA was worst in eyes with RE of 0.25 to 0.50 D (0.35 ± 0.07 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.020) and in eyes with RE of -0.25 to -0.01 D (P = 0.028). The UNVA was worst in eyes with RE of 0.25 to 0.50 D (0.40 ± 0.14 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.022), which suggests that the extent of monovision should be limited up to -0.50 diopter. On univariate analysis for UNVA in eyes with a RE within ± 0.25 D, the anterior chamber depth (R = 0.257; P = 0.037) and pupil size (R = 0.451; P < 0.001) had a statistically significant relation to UNVA, while multivariate analysis showed the pupil size (β = 0.451; P < 0.001) as the sole indicator, suggesting eyes with a small pupil size might receive a UNVA benefit.
format Online
Article
Text
id pubmed-9704673
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97046732022-11-29 Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation Jeon, Sohee Choi, Ayoung Kwon, Hyunggoo PLoS One Research Article A newly developed extended-depth-of-focus AcrySof(®) Vivity™ intraocular lens (IOL), which has a wavefront-shaped anterior surface, has shown a promising outcome in minimizing dysphotopsia, the biggest issue after diffractive type IOL implantation. On the contrary, relatively low uncorrected near visual acuity (UNVA) has been raised as a demerit of this IOL. However, there is only limited information about the UNVA after Vivity implantation. In the present study, we compared the uncorrected distant and intermediate visual acuity (UDVA and UIVA) and UNVA according to the range of refractive error (RE) from 91 eyes from 91 patients implanted with Vivity IOL. Then we assessed the biometric factors for their association with UNVA from 66 eyes with a RE within ± 0.25 D. The UDVA was worst in eyes with RE < -0.50 D (0.17 ± 0.21), which was significantly worse than in any other group (P < 0.001 for every analysis). The UIVA was worst in eyes with RE of 0.25 to 0.50 D (0.35 ± 0.07 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.020) and in eyes with RE of -0.25 to -0.01 D (P = 0.028). The UNVA was worst in eyes with RE of 0.25 to 0.50 D (0.40 ± 0.14 D), which was significantly worse than in eyes with RE of -0.50 to -0.26 D (P = 0.022), which suggests that the extent of monovision should be limited up to -0.50 diopter. On univariate analysis for UNVA in eyes with a RE within ± 0.25 D, the anterior chamber depth (R = 0.257; P = 0.037) and pupil size (R = 0.451; P < 0.001) had a statistically significant relation to UNVA, while multivariate analysis showed the pupil size (β = 0.451; P < 0.001) as the sole indicator, suggesting eyes with a small pupil size might receive a UNVA benefit. Public Library of Science 2022-11-28 /pmc/articles/PMC9704673/ /pubmed/36441780 http://dx.doi.org/10.1371/journal.pone.0277687 Text en © 2022 Jeon et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Jeon, Sohee
Choi, Ayoung
Kwon, Hyunggoo
Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title_full Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title_fullStr Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title_full_unstemmed Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title_short Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
title_sort analysis of uncorrected near visual acuity after extended depth-of-focus acrysof® vivity™ intraocular lens implantation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9704673/
https://www.ncbi.nlm.nih.gov/pubmed/36441780
http://dx.doi.org/10.1371/journal.pone.0277687
work_keys_str_mv AT jeonsohee analysisofuncorrectednearvisualacuityafterextendeddepthoffocusacrysofvivityintraocularlensimplantation
AT choiayoung analysisofuncorrectednearvisualacuityafterextendeddepthoffocusacrysofvivityintraocularlensimplantation
AT kwonhyunggoo analysisofuncorrectednearvisualacuityafterextendeddepthoffocusacrysofvivityintraocularlensimplantation