Cargando…

Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy

Background  Computed tomography perfusion (CTp), a useful technique in oncology, is not widely utilized due to the high radiation dose delivered from it. It involves scanning the region of interest every second for 50 seconds following intravenous contrast administration. Doubling sampling interval...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhatt, Shuchi, Mandal, Samrat, Mehrotra, Gopesh, Arora, Vipin, Singh, Usharani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Pvt. Ltd. 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705123/
https://www.ncbi.nlm.nih.gov/pubmed/36451960
http://dx.doi.org/10.1055/s-0042-1753469
_version_ 1784840206611906560
author Bhatt, Shuchi
Mandal, Samrat
Mehrotra, Gopesh
Arora, Vipin
Singh, Usharani
author_facet Bhatt, Shuchi
Mandal, Samrat
Mehrotra, Gopesh
Arora, Vipin
Singh, Usharani
author_sort Bhatt, Shuchi
collection PubMed
description Background  Computed tomography perfusion (CTp), a useful technique in oncology, is not widely utilized due to the high radiation dose delivered from it. It involves scanning the region of interest every second for 50 seconds following intravenous contrast administration. Doubling sampling interval (SI) to 2 seconds will half the radiation dose, but may impact its effectiveness, which needs to be evaluated. Objectives  To evaluate a dose reduction strategy in CTp by determining agreement between standard dose (SD) CTp (acquisition with SI 1 second) and low-dose CTp techniques with SI of 2 seconds (achieved either by reconstruction only or true low-dose acquisition). Materials and methods  This cross-sectional study was conducted on histopathology-proven head and neck squamous cell carcinoma (HNSCC) patients who underwent CTp on 64 slice multidetector CT. A total of 56 patients had SD and 24 patients underwent true low dose (LD) acquisition. SD data were also reconstructed at SI 2 seconds to obtain a dataset simulating low dose (low-dose reconstruction [LDr]). Paired t -test was applied to compare CTp in SD and LDr groups and the Bland–Altman plot drawn to calculate 95% confidence limit of agreement. The Kolmogorov–Smirnov test compared CTp parameters for LDr and LD groups. Results  There was no statistical difference in CTp parameters (except blood flow in malignant) in SD and LDr groups for both malignant and normal tissues. CTp of malignant tissue was not statistically different in LDr and LD groups but the radiation dose was half in the LD group. Conclusion  Reduction of radiation dose to half achieved by doubling the SI does not affect the CTp parameters significantly. So LD acquisitions will increase the use of CTp in HNSCC.
format Online
Article
Text
id pubmed-9705123
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-97051232022-11-29 Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy Bhatt, Shuchi Mandal, Samrat Mehrotra, Gopesh Arora, Vipin Singh, Usharani Indian J Radiol Imaging Background  Computed tomography perfusion (CTp), a useful technique in oncology, is not widely utilized due to the high radiation dose delivered from it. It involves scanning the region of interest every second for 50 seconds following intravenous contrast administration. Doubling sampling interval (SI) to 2 seconds will half the radiation dose, but may impact its effectiveness, which needs to be evaluated. Objectives  To evaluate a dose reduction strategy in CTp by determining agreement between standard dose (SD) CTp (acquisition with SI 1 second) and low-dose CTp techniques with SI of 2 seconds (achieved either by reconstruction only or true low-dose acquisition). Materials and methods  This cross-sectional study was conducted on histopathology-proven head and neck squamous cell carcinoma (HNSCC) patients who underwent CTp on 64 slice multidetector CT. A total of 56 patients had SD and 24 patients underwent true low dose (LD) acquisition. SD data were also reconstructed at SI 2 seconds to obtain a dataset simulating low dose (low-dose reconstruction [LDr]). Paired t -test was applied to compare CTp in SD and LDr groups and the Bland–Altman plot drawn to calculate 95% confidence limit of agreement. The Kolmogorov–Smirnov test compared CTp parameters for LDr and LD groups. Results  There was no statistical difference in CTp parameters (except blood flow in malignant) in SD and LDr groups for both malignant and normal tissues. CTp of malignant tissue was not statistically different in LDr and LD groups but the radiation dose was half in the LD group. Conclusion  Reduction of radiation dose to half achieved by doubling the SI does not affect the CTp parameters significantly. So LD acquisitions will increase the use of CTp in HNSCC. Thieme Medical and Scientific Publishers Pvt. Ltd. 2022-07-31 /pmc/articles/PMC9705123/ /pubmed/36451960 http://dx.doi.org/10.1055/s-0042-1753469 Text en Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Bhatt, Shuchi
Mandal, Samrat
Mehrotra, Gopesh
Arora, Vipin
Singh, Usharani
Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title_full Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title_fullStr Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title_full_unstemmed Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title_short Multidetector Computed Tomography Perfusion in Head and Neck Squamous Cell Carcinomas: Evaluation of a Dose Reduction Strategy
title_sort multidetector computed tomography perfusion in head and neck squamous cell carcinomas: evaluation of a dose reduction strategy
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705123/
https://www.ncbi.nlm.nih.gov/pubmed/36451960
http://dx.doi.org/10.1055/s-0042-1753469
work_keys_str_mv AT bhattshuchi multidetectorcomputedtomographyperfusioninheadandnecksquamouscellcarcinomasevaluationofadosereductionstrategy
AT mandalsamrat multidetectorcomputedtomographyperfusioninheadandnecksquamouscellcarcinomasevaluationofadosereductionstrategy
AT mehrotragopesh multidetectorcomputedtomographyperfusioninheadandnecksquamouscellcarcinomasevaluationofadosereductionstrategy
AT aroravipin multidetectorcomputedtomographyperfusioninheadandnecksquamouscellcarcinomasevaluationofadosereductionstrategy
AT singhusharani multidetectorcomputedtomographyperfusioninheadandnecksquamouscellcarcinomasevaluationofadosereductionstrategy