Cargando…
Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability
Dynamic anterior stabilization using the long head of the biceps tendon is a recently described technique in the management of recurrent shoulder dislocation with subcritical bone loss. This technique involves the transfer of the long head of the biceps to the glenoid, providing sling and hammock ef...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705597/ https://www.ncbi.nlm.nih.gov/pubmed/36457392 http://dx.doi.org/10.1016/j.eats.2022.07.007 |
_version_ | 1784840320517668864 |
---|---|
author | Nair, Ayyappan V. Mohan, Pramod Kumar Jangale, Ajit Kuntwad, Vikas Kumar, M. Praveen Goud, Naresh Sreekumar, Shekhar |
author_facet | Nair, Ayyappan V. Mohan, Pramod Kumar Jangale, Ajit Kuntwad, Vikas Kumar, M. Praveen Goud, Naresh Sreekumar, Shekhar |
author_sort | Nair, Ayyappan V. |
collection | PubMed |
description | Dynamic anterior stabilization using the long head of the biceps tendon is a recently described technique in the management of recurrent shoulder dislocation with subcritical bone loss. This technique involves the transfer of the long head of the biceps to the glenoid, providing sling and hammock effect. The long head of the biceps (LHB) tendon fixation can be accomplished with a variety of implants. We present a modified fixation technique of LHB tendon using transosseous bone tunnel with the adjustable loop length cortical button, incorporating high-strength suture augmentation device in a patient with recurrent glenohumeral instability with limited glenoid bone loss and an engaging Hill-Sachs defect in the humeral head. |
format | Online Article Text |
id | pubmed-9705597 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-97055972022-11-30 Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability Nair, Ayyappan V. Mohan, Pramod Kumar Jangale, Ajit Kuntwad, Vikas Kumar, M. Praveen Goud, Naresh Sreekumar, Shekhar Arthrosc Tech Technical Note Dynamic anterior stabilization using the long head of the biceps tendon is a recently described technique in the management of recurrent shoulder dislocation with subcritical bone loss. This technique involves the transfer of the long head of the biceps to the glenoid, providing sling and hammock effect. The long head of the biceps (LHB) tendon fixation can be accomplished with a variety of implants. We present a modified fixation technique of LHB tendon using transosseous bone tunnel with the adjustable loop length cortical button, incorporating high-strength suture augmentation device in a patient with recurrent glenohumeral instability with limited glenoid bone loss and an engaging Hill-Sachs defect in the humeral head. Elsevier 2022-10-20 /pmc/articles/PMC9705597/ /pubmed/36457392 http://dx.doi.org/10.1016/j.eats.2022.07.007 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Nair, Ayyappan V. Mohan, Pramod Kumar Jangale, Ajit Kuntwad, Vikas Kumar, M. Praveen Goud, Naresh Sreekumar, Shekhar Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title | Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title_full | Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title_fullStr | Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title_full_unstemmed | Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title_short | Dynamic Anterior Stabilization Using Transosseous Bone Tunnel Technique With the Adjustable Loop Length Cortical Button Incorporating High-Strength Suture Augmentation for Recurrent Shoulder Instability |
title_sort | dynamic anterior stabilization using transosseous bone tunnel technique with the adjustable loop length cortical button incorporating high-strength suture augmentation for recurrent shoulder instability |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705597/ https://www.ncbi.nlm.nih.gov/pubmed/36457392 http://dx.doi.org/10.1016/j.eats.2022.07.007 |
work_keys_str_mv | AT nairayyappanv dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT mohanpramodkumar dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT jangaleajit dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT kuntwadvikas dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT kumarmpraveen dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT goudnaresh dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability AT sreekumarshekhar dynamicanteriorstabilizationusingtransosseousbonetunneltechniquewiththeadjustablelooplengthcorticalbuttonincorporatinghighstrengthsutureaugmentationforrecurrentshoulderinstability |