Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease
PURPOSE: The objective of this study was to determine whether ultrasound-measured jugular venous pressure (U-JVP) could accurately estimate central venous pressure (CVP). METHODS: This prospective, diagnostic, single-centre study was performed at the Cardiac Intensive Care Unit of the Northern Gener...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705668/ https://www.ncbi.nlm.nih.gov/pubmed/35292924 http://dx.doi.org/10.1007/s40477-022-00654-7 |
_version_ | 1784840326061490176 |
---|---|
author | Jenkins, Sam Knowles, Patrick Briffa, Norman |
author_facet | Jenkins, Sam Knowles, Patrick Briffa, Norman |
author_sort | Jenkins, Sam |
collection | PubMed |
description | PURPOSE: The objective of this study was to determine whether ultrasound-measured jugular venous pressure (U-JVP) could accurately estimate central venous pressure (CVP). METHODS: This prospective, diagnostic, single-centre study was performed at the Cardiac Intensive Care Unit of the Northern General Hospital, Sheffield, UK. Post-cardiac surgery patients were recruited from January to May 2019. The investigators were blinded to the central venous pressure when measuring the jugular venous pressure. U-JVP and direct CVP were measured simultaneously. Measurements were taken whilst the patient was ventilated and then repeated when the patient was extubated, providing non-ventilated readings. RESULTS: One-hundred and fourteen consecutive participants with a male predominance of 71% and mean age of 65 ± 12 years were included in the analysis. Bland–Altman plots revealed that U-JVP marginally overestimated CVP by 0.91 mmHg (95% limits of agreement were −2.936 to 4.754) in ventilated patients and by 0.11 mmHg (95% limits of agreement between −2.481 and 2.695) in non-ventilated patients. Reasonable sensitivity and specificity of ultrasound-measured jugular venous pressure was achieved for low and high central venous pressure in both ventilated and non-ventilated patients. CONCLUSION: U-JVP accurately estimates cardiac filling pressure and fluid status in patients after cardiac surgery, irrespective of their ventilatory status. Jugular venous pressure measurement by insonation is a reliable technique that can be taught to medical students and other health professionals to non-invasively estimate central venous pressure and may be useful for assessment of volaemic status in patients with heart failure. TRIAL REGISTRATION: ClinicalTrials.gov public (identifier NCT03815188). GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40477-022-00654-7. |
format | Online Article Text |
id | pubmed-9705668 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-97056682022-11-30 Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease Jenkins, Sam Knowles, Patrick Briffa, Norman J Ultrasound Original Paper PURPOSE: The objective of this study was to determine whether ultrasound-measured jugular venous pressure (U-JVP) could accurately estimate central venous pressure (CVP). METHODS: This prospective, diagnostic, single-centre study was performed at the Cardiac Intensive Care Unit of the Northern General Hospital, Sheffield, UK. Post-cardiac surgery patients were recruited from January to May 2019. The investigators were blinded to the central venous pressure when measuring the jugular venous pressure. U-JVP and direct CVP were measured simultaneously. Measurements were taken whilst the patient was ventilated and then repeated when the patient was extubated, providing non-ventilated readings. RESULTS: One-hundred and fourteen consecutive participants with a male predominance of 71% and mean age of 65 ± 12 years were included in the analysis. Bland–Altman plots revealed that U-JVP marginally overestimated CVP by 0.91 mmHg (95% limits of agreement were −2.936 to 4.754) in ventilated patients and by 0.11 mmHg (95% limits of agreement between −2.481 and 2.695) in non-ventilated patients. Reasonable sensitivity and specificity of ultrasound-measured jugular venous pressure was achieved for low and high central venous pressure in both ventilated and non-ventilated patients. CONCLUSION: U-JVP accurately estimates cardiac filling pressure and fluid status in patients after cardiac surgery, irrespective of their ventilatory status. Jugular venous pressure measurement by insonation is a reliable technique that can be taught to medical students and other health professionals to non-invasively estimate central venous pressure and may be useful for assessment of volaemic status in patients with heart failure. TRIAL REGISTRATION: ClinicalTrials.gov public (identifier NCT03815188). GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40477-022-00654-7. Springer International Publishing 2022-03-15 /pmc/articles/PMC9705668/ /pubmed/35292924 http://dx.doi.org/10.1007/s40477-022-00654-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Jenkins, Sam Knowles, Patrick Briffa, Norman Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title | Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title_full | Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title_fullStr | Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title_full_unstemmed | Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title_short | Portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
title_sort | portable ultrasound assessment of jugular venous pressure is an accurate method for estimating volaemic status in patients with cardiac disease |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9705668/ https://www.ncbi.nlm.nih.gov/pubmed/35292924 http://dx.doi.org/10.1007/s40477-022-00654-7 |
work_keys_str_mv | AT jenkinssam portableultrasoundassessmentofjugularvenouspressureisanaccuratemethodforestimatingvolaemicstatusinpatientswithcardiacdisease AT knowlespatrick portableultrasoundassessmentofjugularvenouspressureisanaccuratemethodforestimatingvolaemicstatusinpatientswithcardiacdisease AT briffanorman portableultrasoundassessmentofjugularvenouspressureisanaccuratemethodforestimatingvolaemicstatusinpatientswithcardiacdisease |