Cargando…

Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study

Background: The flat occlusal preparation design (FOD) of posterior teeth offers promising results of fracture resistance and stress distribution, but its application in vital teeth is limited as there may be a danger of pulp injury. Although this danger is omitted in endodontically treated teeth, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Nabil, Omnia, Halim, Carl Hany, Mokhtar, Ashraf Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: F1000 Research Limited 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9706146/
https://www.ncbi.nlm.nih.gov/pubmed/36483004
http://dx.doi.org/10.12688/f1000research.19455.2
_version_ 1784840449015414784
author Nabil, Omnia
Halim, Carl Hany
Mokhtar, Ashraf Hassan
author_facet Nabil, Omnia
Halim, Carl Hany
Mokhtar, Ashraf Hassan
author_sort Nabil, Omnia
collection PubMed
description Background: The flat occlusal preparation design (FOD) of posterior teeth offers promising results of fracture resistance and stress distribution, but its application in vital teeth is limited as there may be a danger of pulp injury. Although this danger is omitted in endodontically treated teeth, there is no research work assessing the impact of FOD on the fracture resistance and distribution of stresses among these teeth. The aim of this study was to assess the impact of FOD of endodontically treated molars on the fracture resistance and distribution of stresses among a ceramic crown-molar structure when compared to the two planes occlusal preparation design (TOD). Methods: 20 human mandibular molars were endodontically treated and distributed equally to two groups: Group I (TOD) and Group II (FOD). Ceramic CAD/CAM milled lithium disilicate (IPS e.max CAD) crowns were produced for all preparations and adhered using self-adhesive resin cement. Using a universal testing machine, the fracture resistance test was performed. The fractured samples were examined using a stereomicroscope and scanning electron microscope to determine modes of failure. Stress distribution was evaluated by 3D finite element analysis, which was performed on digital models of endodontically treated mandibular molars (one model for each design). Results: Group II recorded statistically non-significant higher fracture resistance mean values (3107.2± 604.9 N) than Group I mean values (2962.6 ±524.27 N) as indicated by Student’s t-test (t=0.55, p= 0.57). Also, Group II resulted in more favorable failure mode as compared to Group I. Both preparation designs yielded low von-Mises stresses within the factor of safety. However, the stress distribution among different layers of the model differed. Conclusions: FOD having comparable fracture strength to TOD and a more favorable fracture behavior can be used for the preparation of endodontically treated molars.
format Online
Article
Text
id pubmed-9706146
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher F1000 Research Limited
record_format MEDLINE/PubMed
spelling pubmed-97061462022-12-07 Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study Nabil, Omnia Halim, Carl Hany Mokhtar, Ashraf Hassan F1000Res Research Article Background: The flat occlusal preparation design (FOD) of posterior teeth offers promising results of fracture resistance and stress distribution, but its application in vital teeth is limited as there may be a danger of pulp injury. Although this danger is omitted in endodontically treated teeth, there is no research work assessing the impact of FOD on the fracture resistance and distribution of stresses among these teeth. The aim of this study was to assess the impact of FOD of endodontically treated molars on the fracture resistance and distribution of stresses among a ceramic crown-molar structure when compared to the two planes occlusal preparation design (TOD). Methods: 20 human mandibular molars were endodontically treated and distributed equally to two groups: Group I (TOD) and Group II (FOD). Ceramic CAD/CAM milled lithium disilicate (IPS e.max CAD) crowns were produced for all preparations and adhered using self-adhesive resin cement. Using a universal testing machine, the fracture resistance test was performed. The fractured samples were examined using a stereomicroscope and scanning electron microscope to determine modes of failure. Stress distribution was evaluated by 3D finite element analysis, which was performed on digital models of endodontically treated mandibular molars (one model for each design). Results: Group II recorded statistically non-significant higher fracture resistance mean values (3107.2± 604.9 N) than Group I mean values (2962.6 ±524.27 N) as indicated by Student’s t-test (t=0.55, p= 0.57). Also, Group II resulted in more favorable failure mode as compared to Group I. Both preparation designs yielded low von-Mises stresses within the factor of safety. However, the stress distribution among different layers of the model differed. Conclusions: FOD having comparable fracture strength to TOD and a more favorable fracture behavior can be used for the preparation of endodontically treated molars. F1000 Research Limited 2021-06-11 /pmc/articles/PMC9706146/ /pubmed/36483004 http://dx.doi.org/10.12688/f1000research.19455.2 Text en Copyright: © 2021 Nabil O et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Nabil, Omnia
Halim, Carl Hany
Mokhtar, Ashraf Hassan
Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title_full Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title_fullStr Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title_full_unstemmed Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title_short Fracture resistance and 3D finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
title_sort fracture resistance and 3d finite element analysis of machined ceramic crowns bonded to endodontically treated molars with two planes versus flat occlusal preparation designs: an in vitro study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9706146/
https://www.ncbi.nlm.nih.gov/pubmed/36483004
http://dx.doi.org/10.12688/f1000research.19455.2
work_keys_str_mv AT nabilomnia fractureresistanceand3dfiniteelementanalysisofmachinedceramiccrownsbondedtoendodonticallytreatedmolarswithtwoplanesversusflatocclusalpreparationdesignsaninvitrostudy
AT halimcarlhany fractureresistanceand3dfiniteelementanalysisofmachinedceramiccrownsbondedtoendodonticallytreatedmolarswithtwoplanesversusflatocclusalpreparationdesignsaninvitrostudy
AT mokhtarashrafhassan fractureresistanceand3dfiniteelementanalysisofmachinedceramiccrownsbondedtoendodonticallytreatedmolarswithtwoplanesversusflatocclusalpreparationdesignsaninvitrostudy