Cargando…
Capacitance-Based Biosensor for the Measurement of Total Loss of L-Amino Acids in Human Serum during Hemodialysis
[Image: see text] In this paper, we present a biosensor based on a gold nanoparticle (AuNP)-modified Pt electrode with an adjusted membrane containing cross-linked L-amino acid oxidase for the detection and quantification of total L-amino acids. The designed biosensor was tested and characterized us...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9706805/ https://www.ncbi.nlm.nih.gov/pubmed/36268654 http://dx.doi.org/10.1021/acssensors.2c01342 |
_version_ | 1784840574545690624 |
---|---|
author | Miškinis, Justas Ramonas, Eimantas Gurevičienė, Vidutė Razumienė, Julija Dagys, Marius Ratautas, Dalius |
author_facet | Miškinis, Justas Ramonas, Eimantas Gurevičienė, Vidutė Razumienė, Julija Dagys, Marius Ratautas, Dalius |
author_sort | Miškinis, Justas |
collection | PubMed |
description | [Image: see text] In this paper, we present a biosensor based on a gold nanoparticle (AuNP)-modified Pt electrode with an adjusted membrane containing cross-linked L-amino acid oxidase for the detection and quantification of total L-amino acids. The designed biosensor was tested and characterized using the capacitance-based principle, capacitance measurements after electrode polarization, disconnection from the circuit, and addition of the respective amount of the analyte. The method was implemented using the capacitive and catalytic properties of the Pt/AuNP electrode; nanostructures were able to store electric charge while at the same time catalyzing the oxidation of the redox reaction intermediate H(2)O(2). In this way, the Pt/AuNP layer was charged after the addition of analytes, allowing for much more accurate measurements for samples with low amino acid concentrations. The combined biosensor electrode with the capacitance-based measurement method resulted in high sensitivity and a low limit of detection (LOD) for hydrogen peroxide (4.15 μC/μM and 0.86 μM, respectively) and high sensitivity, a low LOD, and a wide linear range for L-amino acids (0.73 μC/μM, 5.5 μM and 25–1500 μM, respectively). The designed biosensor was applied to measure the relative loss of amino acids in patients undergoing renal replacement therapy by analyzing amino acid levels in diluted serum samples before and after entering/leaving the hemodialysis apparatus. In general, the designed biosensor in conjunction with the proposed capacitance-based method was clinically tested and could also be applied for the detection of other analytes using analyte-specific oxidases. |
format | Online Article Text |
id | pubmed-9706805 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-97068052022-11-30 Capacitance-Based Biosensor for the Measurement of Total Loss of L-Amino Acids in Human Serum during Hemodialysis Miškinis, Justas Ramonas, Eimantas Gurevičienė, Vidutė Razumienė, Julija Dagys, Marius Ratautas, Dalius ACS Sens [Image: see text] In this paper, we present a biosensor based on a gold nanoparticle (AuNP)-modified Pt electrode with an adjusted membrane containing cross-linked L-amino acid oxidase for the detection and quantification of total L-amino acids. The designed biosensor was tested and characterized using the capacitance-based principle, capacitance measurements after electrode polarization, disconnection from the circuit, and addition of the respective amount of the analyte. The method was implemented using the capacitive and catalytic properties of the Pt/AuNP electrode; nanostructures were able to store electric charge while at the same time catalyzing the oxidation of the redox reaction intermediate H(2)O(2). In this way, the Pt/AuNP layer was charged after the addition of analytes, allowing for much more accurate measurements for samples with low amino acid concentrations. The combined biosensor electrode with the capacitance-based measurement method resulted in high sensitivity and a low limit of detection (LOD) for hydrogen peroxide (4.15 μC/μM and 0.86 μM, respectively) and high sensitivity, a low LOD, and a wide linear range for L-amino acids (0.73 μC/μM, 5.5 μM and 25–1500 μM, respectively). The designed biosensor was applied to measure the relative loss of amino acids in patients undergoing renal replacement therapy by analyzing amino acid levels in diluted serum samples before and after entering/leaving the hemodialysis apparatus. In general, the designed biosensor in conjunction with the proposed capacitance-based method was clinically tested and could also be applied for the detection of other analytes using analyte-specific oxidases. American Chemical Society 2022-10-21 2022-11-25 /pmc/articles/PMC9706805/ /pubmed/36268654 http://dx.doi.org/10.1021/acssensors.2c01342 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Miškinis, Justas Ramonas, Eimantas Gurevičienė, Vidutė Razumienė, Julija Dagys, Marius Ratautas, Dalius Capacitance-Based Biosensor for the Measurement of Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title | Capacitance-Based
Biosensor for the Measurement of
Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title_full | Capacitance-Based
Biosensor for the Measurement of
Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title_fullStr | Capacitance-Based
Biosensor for the Measurement of
Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title_full_unstemmed | Capacitance-Based
Biosensor for the Measurement of
Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title_short | Capacitance-Based
Biosensor for the Measurement of
Total Loss of L-Amino Acids in Human Serum during Hemodialysis |
title_sort | capacitance-based
biosensor for the measurement of
total loss of l-amino acids in human serum during hemodialysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9706805/ https://www.ncbi.nlm.nih.gov/pubmed/36268654 http://dx.doi.org/10.1021/acssensors.2c01342 |
work_keys_str_mv | AT miskinisjustas capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis AT ramonaseimantas capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis AT gurevicienevidute capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis AT razumienejulija capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis AT dagysmarius capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis AT ratautasdalius capacitancebasedbiosensorforthemeasurementoftotallossoflaminoacidsinhumanserumduringhemodialysis |