Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study

BACKGROUND AND PURPOSE: Minimally invasive spine surgery has continuously evolved for specific surgical procedures and patient populations to lower morbidity and the risk of postoperative bacterial infection. Perioperative antibiotic prophylaxis is an important preventive measure and local tissue co...

Descripción completa

Detalles Bibliográficos
Autores principales: HVISTENDAHL, Magnus A, HANBERG, Pelle, STILLING, Maiken, KASPERSEN, Alexander Emil, HØY, Kristian, BUE, Mats
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9707378/
https://www.ncbi.nlm.nih.gov/pubmed/36445157
http://dx.doi.org/10.2340/17453674.2022.5276
_version_ 1784840703335989248
author HVISTENDAHL, Magnus A
HANBERG, Pelle
STILLING, Maiken
KASPERSEN, Alexander Emil
HØY, Kristian
BUE, Mats
author_facet HVISTENDAHL, Magnus A
HANBERG, Pelle
STILLING, Maiken
KASPERSEN, Alexander Emil
HØY, Kristian
BUE, Mats
author_sort HVISTENDAHL, Magnus A
collection PubMed
description BACKGROUND AND PURPOSE: Minimally invasive spine surgery has continuously evolved for specific surgical procedures and patient populations to lower morbidity and the risk of postoperative bacterial infection. Perioperative antibiotic prophylaxis is an important preventive measure and local tissue concentrations can be quantified with microdialysis. Insertion of spinal implants induces tissue trauma and inflammation, which may affect antibiotic proximate implant concentrations. We compared perioperative cefuroxime concentrations inside a cannulated pedicle screw used in minimally invasive spine surgery with the opposite non-instrumented vertebral pedicle. MATERIALS AND METHODS: Microdialysis catheters were placed inside a cannulated pedicle screw and in the opposite non-instrumented vertebral pedicle of the same vertebra (L1) in 8 female pigs through a posterior lumbar surgical approach. Following a single-dose intravenous cefuroxime administration (1.5 g), dialysates and plasma were dynamically sampled over 8 hours. The primary endpoint was time above the cefuroxime clinical breakpoint minimal inhibitory concentration for Staphylococcus aureus of 4 µg/mL (T>MIC4). RESULTS: Median T>MIC4 was 0 h (range 0–0) inside the cannulated pedicle screw, 1.6 h (range 1.1–2.4) in non-instrumented vertebral pedicle, and 1.9 h (range 1.9–2.9) in plasma. CONCLUSION: A single-dose intravenous cefuroxime administration provided low and subtherapeutic concentrations for prevention of infection inside a cannulated pedicle screw in the lumbar spine. Therapeutic concentrations were achieved in the opposite non-instrumented vertebral pedicle up to 1.5–2 h. Therefore, additional prophylactic strategies may be considered in cannulated instrumented spine surgery, especially in high-risk patients. Alternative dosing regimens seem relevant in lumbar spine surgery lasting longer than 1.5 h.
format Online
Article
Text
id pubmed-9707378
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation
record_format MEDLINE/PubMed
spelling pubmed-97073782022-11-30 Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study HVISTENDAHL, Magnus A HANBERG, Pelle STILLING, Maiken KASPERSEN, Alexander Emil HØY, Kristian BUE, Mats Acta Orthop Article BACKGROUND AND PURPOSE: Minimally invasive spine surgery has continuously evolved for specific surgical procedures and patient populations to lower morbidity and the risk of postoperative bacterial infection. Perioperative antibiotic prophylaxis is an important preventive measure and local tissue concentrations can be quantified with microdialysis. Insertion of spinal implants induces tissue trauma and inflammation, which may affect antibiotic proximate implant concentrations. We compared perioperative cefuroxime concentrations inside a cannulated pedicle screw used in minimally invasive spine surgery with the opposite non-instrumented vertebral pedicle. MATERIALS AND METHODS: Microdialysis catheters were placed inside a cannulated pedicle screw and in the opposite non-instrumented vertebral pedicle of the same vertebra (L1) in 8 female pigs through a posterior lumbar surgical approach. Following a single-dose intravenous cefuroxime administration (1.5 g), dialysates and plasma were dynamically sampled over 8 hours. The primary endpoint was time above the cefuroxime clinical breakpoint minimal inhibitory concentration for Staphylococcus aureus of 4 µg/mL (T>MIC4). RESULTS: Median T>MIC4 was 0 h (range 0–0) inside the cannulated pedicle screw, 1.6 h (range 1.1–2.4) in non-instrumented vertebral pedicle, and 1.9 h (range 1.9–2.9) in plasma. CONCLUSION: A single-dose intravenous cefuroxime administration provided low and subtherapeutic concentrations for prevention of infection inside a cannulated pedicle screw in the lumbar spine. Therapeutic concentrations were achieved in the opposite non-instrumented vertebral pedicle up to 1.5–2 h. Therefore, additional prophylactic strategies may be considered in cannulated instrumented spine surgery, especially in high-risk patients. Alternative dosing regimens seem relevant in lumbar spine surgery lasting longer than 1.5 h. Medical Journals Sweden, on behalf of the Nordic Orthopedic Federation 2022-11-28 /pmc/articles/PMC9707378/ /pubmed/36445157 http://dx.doi.org/10.2340/17453674.2022.5276 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work.
spellingShingle Article
HVISTENDAHL, Magnus A
HANBERG, Pelle
STILLING, Maiken
KASPERSEN, Alexander Emil
HØY, Kristian
BUE, Mats
Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title_full Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title_fullStr Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title_full_unstemmed Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title_short Subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
title_sort subtherapeutic levels of cefuroxime inside a cannulated pedicle screw used in spine surgery: results from a porcine microdialysis study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9707378/
https://www.ncbi.nlm.nih.gov/pubmed/36445157
http://dx.doi.org/10.2340/17453674.2022.5276
work_keys_str_mv AT hvistendahlmagnusa subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy
AT hanbergpelle subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy
AT stillingmaiken subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy
AT kaspersenalexanderemil subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy
AT høykristian subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy
AT buemats subtherapeuticlevelsofcefuroximeinsideacannulatedpediclescrewusedinspinesurgeryresultsfromaporcinemicrodialysisstudy