Cargando…
Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti
BACKGROUND: Lot Quality Assurance Sampling (LQAS), a tool used for monitoring health indicators in low resource settings resulting in “high” or “low” classifications, assumes that determination of the trait of interest is perfect. This is often not true for diagnostic tests, with imperfect sensitivi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9707425/ https://www.ncbi.nlm.nih.gov/pubmed/36447195 http://dx.doi.org/10.1186/s12889-022-14206-5 |
_version_ | 1784840713348841472 |
---|---|
author | Fulcher, Isabel R. Clisbee, Mary Lambert, Wesler Leandre, Fernet Renand Hedt-Gauthier, Bethany |
author_facet | Fulcher, Isabel R. Clisbee, Mary Lambert, Wesler Leandre, Fernet Renand Hedt-Gauthier, Bethany |
author_sort | Fulcher, Isabel R. |
collection | PubMed |
description | BACKGROUND: Lot Quality Assurance Sampling (LQAS), a tool used for monitoring health indicators in low resource settings resulting in “high” or “low” classifications, assumes that determination of the trait of interest is perfect. This is often not true for diagnostic tests, with imperfect sensitivity and specificity. Here, we develop Lot Quality Assurance Sampling for Imperfect Tests (LQAS-IMP) to address this issue and apply it to a COVID-19 serosurveillance study design in Haiti. METHODS: We first derive a modified procedure, LQAS-IMP, that accounts for the sensitivity and specificity of a diagnostic test to yield correct classification errors. We then apply the novel LQAS-IMP to design an LQAS system to classify prevalence of SARS-CoV-2 antibodies among healthcare workers at eleven Zanmia Lasante health facilities in Haiti. Finally, we show the performance of the LQAS-IMP procedure in a simulation study. RESULTS: We found that when an imperfect diagnostic test is used, the classification errors in the standard LQAS procedure are larger than specified. In the modified LQAS-IMP procedure, classification errors are consistent with the specified maximum classification error. We then utilized the LQAS-IMP procedure to define valid systems for sampling at eleven hospitals in Haiti. CONCLUSION: The LQAS-IMP procedure accounts for imperfect sensitivity and specificity in system design; if the accuracy of a test is known, the use of LQAS-IMP extends LQAS to applications for indicators that are based on laboratory tests, such as SARS-CoV-2 antibodies. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12889-022-14206-5. |
format | Online Article Text |
id | pubmed-9707425 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97074252022-11-29 Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti Fulcher, Isabel R. Clisbee, Mary Lambert, Wesler Leandre, Fernet Renand Hedt-Gauthier, Bethany BMC Public Health Research BACKGROUND: Lot Quality Assurance Sampling (LQAS), a tool used for monitoring health indicators in low resource settings resulting in “high” or “low” classifications, assumes that determination of the trait of interest is perfect. This is often not true for diagnostic tests, with imperfect sensitivity and specificity. Here, we develop Lot Quality Assurance Sampling for Imperfect Tests (LQAS-IMP) to address this issue and apply it to a COVID-19 serosurveillance study design in Haiti. METHODS: We first derive a modified procedure, LQAS-IMP, that accounts for the sensitivity and specificity of a diagnostic test to yield correct classification errors. We then apply the novel LQAS-IMP to design an LQAS system to classify prevalence of SARS-CoV-2 antibodies among healthcare workers at eleven Zanmia Lasante health facilities in Haiti. Finally, we show the performance of the LQAS-IMP procedure in a simulation study. RESULTS: We found that when an imperfect diagnostic test is used, the classification errors in the standard LQAS procedure are larger than specified. In the modified LQAS-IMP procedure, classification errors are consistent with the specified maximum classification error. We then utilized the LQAS-IMP procedure to define valid systems for sampling at eleven hospitals in Haiti. CONCLUSION: The LQAS-IMP procedure accounts for imperfect sensitivity and specificity in system design; if the accuracy of a test is known, the use of LQAS-IMP extends LQAS to applications for indicators that are based on laboratory tests, such as SARS-CoV-2 antibodies. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12889-022-14206-5. BioMed Central 2022-11-29 /pmc/articles/PMC9707425/ /pubmed/36447195 http://dx.doi.org/10.1186/s12889-022-14206-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Fulcher, Isabel R. Clisbee, Mary Lambert, Wesler Leandre, Fernet Renand Hedt-Gauthier, Bethany Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title | Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title_full | Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title_fullStr | Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title_full_unstemmed | Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title_short | Adapting Lot Quality Assurance Sampling to accommodate imperfect diagnostic tests: application to COVID-19 serosurveillance in Haiti |
title_sort | adapting lot quality assurance sampling to accommodate imperfect diagnostic tests: application to covid-19 serosurveillance in haiti |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9707425/ https://www.ncbi.nlm.nih.gov/pubmed/36447195 http://dx.doi.org/10.1186/s12889-022-14206-5 |
work_keys_str_mv | AT fulcherisabelr adaptinglotqualityassurancesamplingtoaccommodateimperfectdiagnostictestsapplicationtocovid19serosurveillanceinhaiti AT clisbeemary adaptinglotqualityassurancesamplingtoaccommodateimperfectdiagnostictestsapplicationtocovid19serosurveillanceinhaiti AT lambertwesler adaptinglotqualityassurancesamplingtoaccommodateimperfectdiagnostictestsapplicationtocovid19serosurveillanceinhaiti AT leandrefernetrenand adaptinglotqualityassurancesamplingtoaccommodateimperfectdiagnostictestsapplicationtocovid19serosurveillanceinhaiti AT hedtgauthierbethany adaptinglotqualityassurancesamplingtoaccommodateimperfectdiagnostictestsapplicationtocovid19serosurveillanceinhaiti |