Cargando…

Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study

AIM: Screw loosening is a very common cause of failures in implant prosthodontics. In order to avoid screw fracture, it is imperative to understand the mechanical behavior of the screw and the dynamics it is subjected to intraorally. The present study was conducted to qualitatively evaluate and comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Singh, Mansi, Bhargava, Akshay, Nagpal, Abhishek, Chaudhary, Aditya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9709871/
https://www.ncbi.nlm.nih.gov/pubmed/36511074
http://dx.doi.org/10.4103/jips.jips_48_22
_version_ 1784841254081658880
author Singh, Mansi
Bhargava, Akshay
Nagpal, Abhishek
Chaudhary, Aditya
author_facet Singh, Mansi
Bhargava, Akshay
Nagpal, Abhishek
Chaudhary, Aditya
author_sort Singh, Mansi
collection PubMed
description AIM: Screw loosening is a very common cause of failures in implant prosthodontics. In order to avoid screw fracture, it is imperative to understand the mechanical behavior of the screw and the dynamics it is subjected to intraorally. The present study was conducted to qualitatively evaluate and compare the morphological changes, surface defects, and cracks observed under a scanning electron microscope (SEM) in the prosthetic screw. SETTINGS AND DESIGN: Two Stainless steel edentulous mandible models were fabricated on the basis of all on four and all on six concepts by using CAD design. Screw retained prosthesis were fabricated for both the models and total number of 80 prosthetic screws were made up of Ti6Al4V. MATERIALS AND METHODS: Eighty prosthetic screws (N = 80) used in four- and six-unit implant-retained cast hybrid denture were subjected to cyclic loading of 1.5 million cycles and 3 million cycles, simulating a 5 and 10 years of usage, respectively. Once the simulated cycles had been completed in all subgroups, each prosthetic screw was inspected under SEM (×150–×1000) for any changes. STATISTICAL ANALYSIS: The data thus obtained were statistically analyzed using SPSS 12.0 software and P < 0.005 was considered statistically significant. RESULTS: The study revealed statistically significant (P < 0.005) changes (like morphological changes, surface defects, crack initiation, and propagation) in the prosthetic screws after exposing them to predefined test conditions (P < 0.001). CONCLUSION: It can be concluded that the prosthetic screws need to be changed after a period of clinical use of 5 years irrespective of the number of implants used for rehabilitation. Further, the tilt of the abutment and numbers of implants also contribute to the stresses on the implant-supported prostheses.
format Online
Article
Text
id pubmed-9709871
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-97098712023-10-01 Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study Singh, Mansi Bhargava, Akshay Nagpal, Abhishek Chaudhary, Aditya J Indian Prosthodont Soc Research AIM: Screw loosening is a very common cause of failures in implant prosthodontics. In order to avoid screw fracture, it is imperative to understand the mechanical behavior of the screw and the dynamics it is subjected to intraorally. The present study was conducted to qualitatively evaluate and compare the morphological changes, surface defects, and cracks observed under a scanning electron microscope (SEM) in the prosthetic screw. SETTINGS AND DESIGN: Two Stainless steel edentulous mandible models were fabricated on the basis of all on four and all on six concepts by using CAD design. Screw retained prosthesis were fabricated for both the models and total number of 80 prosthetic screws were made up of Ti6Al4V. MATERIALS AND METHODS: Eighty prosthetic screws (N = 80) used in four- and six-unit implant-retained cast hybrid denture were subjected to cyclic loading of 1.5 million cycles and 3 million cycles, simulating a 5 and 10 years of usage, respectively. Once the simulated cycles had been completed in all subgroups, each prosthetic screw was inspected under SEM (×150–×1000) for any changes. STATISTICAL ANALYSIS: The data thus obtained were statistically analyzed using SPSS 12.0 software and P < 0.005 was considered statistically significant. RESULTS: The study revealed statistically significant (P < 0.005) changes (like morphological changes, surface defects, crack initiation, and propagation) in the prosthetic screws after exposing them to predefined test conditions (P < 0.001). CONCLUSION: It can be concluded that the prosthetic screws need to be changed after a period of clinical use of 5 years irrespective of the number of implants used for rehabilitation. Further, the tilt of the abutment and numbers of implants also contribute to the stresses on the implant-supported prostheses. Wolters Kluwer - Medknow 2022 2022-10-03 /pmc/articles/PMC9709871/ /pubmed/36511074 http://dx.doi.org/10.4103/jips.jips_48_22 Text en Copyright: © 2022 The Journal of Indian Prosthodontic Society https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Research
Singh, Mansi
Bhargava, Akshay
Nagpal, Abhishek
Chaudhary, Aditya
Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title_full Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title_fullStr Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title_full_unstemmed Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title_short Evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: An in vitro study
title_sort evaluation of physical changes due to simulated loading on prosthetic screw supporting 4- and 6-unit implant prosthesis: an in vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9709871/
https://www.ncbi.nlm.nih.gov/pubmed/36511074
http://dx.doi.org/10.4103/jips.jips_48_22
work_keys_str_mv AT singhmansi evaluationofphysicalchangesduetosimulatedloadingonprostheticscrewsupporting4and6unitimplantprosthesisaninvitrostudy
AT bhargavaakshay evaluationofphysicalchangesduetosimulatedloadingonprostheticscrewsupporting4and6unitimplantprosthesisaninvitrostudy
AT nagpalabhishek evaluationofphysicalchangesduetosimulatedloadingonprostheticscrewsupporting4and6unitimplantprosthesisaninvitrostudy
AT chaudharyaditya evaluationofphysicalchangesduetosimulatedloadingonprostheticscrewsupporting4and6unitimplantprosthesisaninvitrostudy