Cargando…

Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology

[Image: see text] A simple, inexpensive, rapid, and label-free detection of phenylarsine oxide (PAO) in the field is a significant and unmet need because of its fatally acute and chronic effects on human health. A simple, fast, sensitive, and relatively low-cost arsenic detection system with an eco-...

Descripción completa

Detalles Bibliográficos
Autores principales: Keser, Kübra, Soylu, Mehmet Çağrı
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713887/
https://www.ncbi.nlm.nih.gov/pubmed/36467944
http://dx.doi.org/10.1021/acsomega.2c05516
_version_ 1784842110880448512
author Keser, Kübra
Soylu, Mehmet Çağrı
author_facet Keser, Kübra
Soylu, Mehmet Çağrı
author_sort Keser, Kübra
collection PubMed
description [Image: see text] A simple, inexpensive, rapid, and label-free detection of phenylarsine oxide (PAO) in the field is a significant and unmet need because of its fatally acute and chronic effects on human health. A simple, fast, sensitive, and relatively low-cost arsenic detection system with an eco-friendly sensor could fill this gap. To monitor arsenic in situ, a reliable, portable impedimetric electrochemical sensor is the most suitable platform, which is real-time, fast, low-cost, and easy to design and use and has high sensitivity at low detection limits in the nanogram per mL range. The detection system in this study has a patent-applied green sensor with minimum harm to nature and the potential to dissolve in nature. The electrode containing 15 mL of distilled water (DIW) + 2 g gelatin + 1.75 g glycerol was determined to be the most suitable for determining the amount of inorganic arsenic in the range of 1–100 ng/mL using a gelatin-based solid electrochemical sensor enriched with 2-mercaptoethanol. Impedance measurements were performed to analyze the stability of the sensor in both deionized water and drinking water, as well as for arsenic detection. Among the procedures examined, the procedure prepared with 15 mL DIW + 2 g glycerol + 1.75 g gelatin resulted in the best stability in aqueous medium and in sensitivity with resistance changes (−ΔR(ct) (%)) of 12% (±0.62%), 26% (±2.3%), and 40% (±3.8%) for the concentrations of 1, 10, and 100 ng/mL PAO in drinking water, respectively. With this detection methodology, there is the potential to detect not only arsenic but also other heavy metals in waters and different biomarkers in human fluids.
format Online
Article
Text
id pubmed-9713887
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-97138872022-12-02 Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology Keser, Kübra Soylu, Mehmet Çağrı ACS Omega [Image: see text] A simple, inexpensive, rapid, and label-free detection of phenylarsine oxide (PAO) in the field is a significant and unmet need because of its fatally acute and chronic effects on human health. A simple, fast, sensitive, and relatively low-cost arsenic detection system with an eco-friendly sensor could fill this gap. To monitor arsenic in situ, a reliable, portable impedimetric electrochemical sensor is the most suitable platform, which is real-time, fast, low-cost, and easy to design and use and has high sensitivity at low detection limits in the nanogram per mL range. The detection system in this study has a patent-applied green sensor with minimum harm to nature and the potential to dissolve in nature. The electrode containing 15 mL of distilled water (DIW) + 2 g gelatin + 1.75 g glycerol was determined to be the most suitable for determining the amount of inorganic arsenic in the range of 1–100 ng/mL using a gelatin-based solid electrochemical sensor enriched with 2-mercaptoethanol. Impedance measurements were performed to analyze the stability of the sensor in both deionized water and drinking water, as well as for arsenic detection. Among the procedures examined, the procedure prepared with 15 mL DIW + 2 g glycerol + 1.75 g gelatin resulted in the best stability in aqueous medium and in sensitivity with resistance changes (−ΔR(ct) (%)) of 12% (±0.62%), 26% (±2.3%), and 40% (±3.8%) for the concentrations of 1, 10, and 100 ng/mL PAO in drinking water, respectively. With this detection methodology, there is the potential to detect not only arsenic but also other heavy metals in waters and different biomarkers in human fluids. American Chemical Society 2022-11-15 /pmc/articles/PMC9713887/ /pubmed/36467944 http://dx.doi.org/10.1021/acsomega.2c05516 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Keser, Kübra
Soylu, Mehmet Çağrı
Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title_full Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title_fullStr Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title_full_unstemmed Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title_short Detection of Phenylarsine Oxide in Drinking Water Using an Impedimetric Electrochemical Sensor with Gelatin-Based Solid Electrolyte Enriched with Mercaptoethanol: A Novel Prospective Green Biosensor Methodology
title_sort detection of phenylarsine oxide in drinking water using an impedimetric electrochemical sensor with gelatin-based solid electrolyte enriched with mercaptoethanol: a novel prospective green biosensor methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713887/
https://www.ncbi.nlm.nih.gov/pubmed/36467944
http://dx.doi.org/10.1021/acsomega.2c05516
work_keys_str_mv AT keserkubra detectionofphenylarsineoxideindrinkingwaterusinganimpedimetricelectrochemicalsensorwithgelatinbasedsolidelectrolyteenrichedwithmercaptoethanolanovelprospectivegreenbiosensormethodology
AT soylumehmetcagrı detectionofphenylarsineoxideindrinkingwaterusinganimpedimetricelectrochemicalsensorwithgelatinbasedsolidelectrolyteenrichedwithmercaptoethanolanovelprospectivegreenbiosensormethodology