Cargando…
Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method
BACKGROUND: Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance t...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713962/ https://www.ncbi.nlm.nih.gov/pubmed/36451233 http://dx.doi.org/10.1186/s40662-022-00317-y |
_version_ | 1784842121996402688 |
---|---|
author | Guo, Dongling Meng, Jiaqi Zhang, Keke He, Wenwen Ma, Shiyu Lu, Zhong-lin Lu, Yi Zhu, Xiangjia |
author_facet | Guo, Dongling Meng, Jiaqi Zhang, Keke He, Wenwen Ma, Shiyu Lu, Zhong-lin Lu, Yi Zhu, Xiangjia |
author_sort | Guo, Dongling |
collection | PubMed |
description | BACKGROUND: Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance to IOL tilt and IOL decentration using the qCSF method. METHODS: Patients undergoing uneventful phacoemulsification and a trifocal IOL (Zeiss AT LISA tri 839MP, Carl Zeiss, Germany) or an extended depth-of-focus (EDOF) IOL (Tecnis Symfony ZXR00, Johnson & Johnsons, USA) implantation were included. Monocular contrast sensitivity was measured using the qCSF method at one month post-surgery. IOL tilt and decentration were measured using an optical aberrometer (OPD-Scan III, NIDEK, Japan). RESULTS: Seventy-two patients/eyes with the 839MP IOL and 64 patients/eyes with the ZXR00 IOL were included. Area under the log CSF (AULCSF) and CS acuity did not differ significantly between the two groups. The ZXR00 IOL group showed better CS at 1 cpd (1.137 ± 0.164 vs. 1.030 ± 0.183 logCS) and 1.5 cpd (1.163 ± 0.163 vs. 1.071 ± 0.161 logCS), while the 839MP IOL group had better CS at 6 cpd (0.855 ± 0.187 vs. 0.735 ± 0.363 logCS). In the 839MP IOL group, all CSF metrics were negatively correlated with IOL tilt (all P < 0.05), while in the ZXR00 IOL group, the CS at 3 cpd had no significant correlation with IOL tilt (P > 0.05). Among myopic eyes, fewer CSF metrics were negatively correlated with IOL tilt in the ZXR00 IOL group than in the 839MP IOL group. No significant correlation was found between CSF metrics and IOL decentration. CONCLUSIONS: The ZXR00 and the 839MP IOL groups presented comparable CSF. CS was negatively correlated with IOL tilt, instead of decentration in multifocal IOLs, particularly among myopic eyes. The ZXR00 IOL had better tolerance to IOL tilt in myopic eyes. |
format | Online Article Text |
id | pubmed-9713962 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97139622022-12-02 Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method Guo, Dongling Meng, Jiaqi Zhang, Keke He, Wenwen Ma, Shiyu Lu, Zhong-lin Lu, Yi Zhu, Xiangjia Eye Vis (Lond) Research BACKGROUND: Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance to IOL tilt and IOL decentration using the qCSF method. METHODS: Patients undergoing uneventful phacoemulsification and a trifocal IOL (Zeiss AT LISA tri 839MP, Carl Zeiss, Germany) or an extended depth-of-focus (EDOF) IOL (Tecnis Symfony ZXR00, Johnson & Johnsons, USA) implantation were included. Monocular contrast sensitivity was measured using the qCSF method at one month post-surgery. IOL tilt and decentration were measured using an optical aberrometer (OPD-Scan III, NIDEK, Japan). RESULTS: Seventy-two patients/eyes with the 839MP IOL and 64 patients/eyes with the ZXR00 IOL were included. Area under the log CSF (AULCSF) and CS acuity did not differ significantly between the two groups. The ZXR00 IOL group showed better CS at 1 cpd (1.137 ± 0.164 vs. 1.030 ± 0.183 logCS) and 1.5 cpd (1.163 ± 0.163 vs. 1.071 ± 0.161 logCS), while the 839MP IOL group had better CS at 6 cpd (0.855 ± 0.187 vs. 0.735 ± 0.363 logCS). In the 839MP IOL group, all CSF metrics were negatively correlated with IOL tilt (all P < 0.05), while in the ZXR00 IOL group, the CS at 3 cpd had no significant correlation with IOL tilt (P > 0.05). Among myopic eyes, fewer CSF metrics were negatively correlated with IOL tilt in the ZXR00 IOL group than in the 839MP IOL group. No significant correlation was found between CSF metrics and IOL decentration. CONCLUSIONS: The ZXR00 and the 839MP IOL groups presented comparable CSF. CS was negatively correlated with IOL tilt, instead of decentration in multifocal IOLs, particularly among myopic eyes. The ZXR00 IOL had better tolerance to IOL tilt in myopic eyes. BioMed Central 2022-12-01 /pmc/articles/PMC9713962/ /pubmed/36451233 http://dx.doi.org/10.1186/s40662-022-00317-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Guo, Dongling Meng, Jiaqi Zhang, Keke He, Wenwen Ma, Shiyu Lu, Zhong-lin Lu, Yi Zhu, Xiangjia Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title | Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title_full | Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title_fullStr | Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title_full_unstemmed | Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title_short | Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
title_sort | tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713962/ https://www.ncbi.nlm.nih.gov/pubmed/36451233 http://dx.doi.org/10.1186/s40662-022-00317-y |
work_keys_str_mv | AT guodongling tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT mengjiaqi tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT zhangkeke tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT hewenwen tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT mashiyu tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT luzhonglin tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT luyi tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod AT zhuxiangjia tolerancetolenstiltanddecentrationoftwomultifocalintraocularlensesusingthequickcontrastsensitivityfunctionmethod |