Cargando…
Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study
BACKGROUND: To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS: In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714062/ https://www.ncbi.nlm.nih.gov/pubmed/36451125 http://dx.doi.org/10.1186/s12886-022-02698-z |
_version_ | 1784842142915493888 |
---|---|
author | Zhu, Qiu-Jian Xing, Xiao-Ying Zhu, Man-Hui Ma, Lie Yuan, You Song, E. |
author_facet | Zhu, Qiu-Jian Xing, Xiao-Ying Zhu, Man-Hui Ma, Lie Yuan, You Song, E. |
author_sort | Zhu, Qiu-Jian |
collection | PubMed |
description | BACKGROUND: To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS: In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland–Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS: The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland–Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS: This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault. |
format | Online Article Text |
id | pubmed-9714062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97140622022-12-02 Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study Zhu, Qiu-Jian Xing, Xiao-Ying Zhu, Man-Hui Ma, Lie Yuan, You Song, E. BMC Ophthalmol Research BACKGROUND: To verify the accuracy and stability of the prediction formula based on the ciliary sulcus diameter and lens thickness and to analyse factors influencing the prediction results. METHODS: In total, 925 eyes from 506 subjects were enrolled in this prospective study between July 1, 2020, and June 30, 2021. Subjects were divided into four seasons, each spanning three months. The target vault was set to be between 300 μm and 700 μm according the prediction formula. The actual vault was measured one month postoperatively. The Bland–Altman test, 95% confidence intervals (95% CI) and 95% limits of agreement (95% LoA) were used to evaluate the agreement between the predicted vault and the actual vault. Eyes with absolute prediction errors greater than 300 μm were further analysed. RESULTS: The mean predicted vaults for the four seasons were 503 ± 99, 494 ± 96, 481 ± 92 and 502 ± 93 μm, while the mean actual vaults were 531 ± 189, 491 ± 179, 464 ± 179 and 529 ± 162 μm, respectively. The predicted and actual vaults of the overall subjects were 493 ± 95 and 500 ± 180 μm, respectively. Of the 925 eyes, 861 eyes (93.08%), 42 eyes (4.54%), and 22 eyes (2.38%) showed a normal vault, high vault, and low vault, respectively. Bland–Altman plots showed that the mean difference between the actual vault and predicted vault overall (± 95% LoA) was 6.43 ± 176.2 μm (-339 to 352 μm). Three UBM features may lead to large prediction errors (more than 300 μm): wide iris-ciliary angle (ICA), iris concavity and anteriorly positioned ciliary body. CONCLUSIONS: This study demonstrated the accuracy and stability of the prediction formula through the validation of a large sample size and a long time span. Wide ICA, iris concavity and anteriorly positioned ciliary body may have an effect on vault. BioMed Central 2022-11-30 /pmc/articles/PMC9714062/ /pubmed/36451125 http://dx.doi.org/10.1186/s12886-022-02698-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhu, Qiu-Jian Xing, Xiao-Ying Zhu, Man-Hui Ma, Lie Yuan, You Song, E. Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title | Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title_full | Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title_fullStr | Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title_full_unstemmed | Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title_short | Validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
title_sort | validation of the vault prediction model based on the sulcus-to-sulcus diameter and lens thickness: a 925-eye prospective study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714062/ https://www.ncbi.nlm.nih.gov/pubmed/36451125 http://dx.doi.org/10.1186/s12886-022-02698-z |
work_keys_str_mv | AT zhuqiujian validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy AT xingxiaoying validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy AT zhumanhui validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy AT malie validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy AT yuanyou validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy AT songe validationofthevaultpredictionmodelbasedonthesulcustosulcusdiameterandlensthicknessa925eyeprospectivestudy |