Cargando…
Stress distribution in pediatric zirconia crowns depending on different tooth preparation and cement type: a finite element analysis
BACKGROUND: In clinical settings, tooth preparation for prefabricated zirconia crowns (PZCs) in the primary dentition varies widely. However, knowledge about the biomechanical behavior of PZCs in various clinical settings is limited. This study was conducted to evaluate the biomechanical behavior of...
Autores principales: | Chung, Sang-Yeop, Lee, Hyeonjong, Chae, Yong Kwon, Jung, Yun Sun, Jo, Su-Sung, Lee, Ko Eun, Choi, Sung Chul, Nam, Ok Hyung |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9714224/ https://www.ncbi.nlm.nih.gov/pubmed/36456927 http://dx.doi.org/10.1186/s12903-022-02596-2 |
Ejemplares similares
-
Feasibility of 3-Dimensional Visual Guides for Preparing Pediatric Zirconia Crowns: An In Vitro Study
por: Kang, Ho Yeon, et al.
Publicado: (2020) -
Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type
por: Ha, Seung-Ryong
Publicado: (2015) -
In Vitro Evaluation of the Effect of Different Luting Cements and Tooth Preparation Angle on the Microleakage of Zirconia Crowns
por: Ebadian, Behnaz, et al.
Publicado: (2021) -
Finite Element Analysis of Dental Implants with Zirconia Crown Restorations: Conventional Cement-Retained vs. Cementless Screw-Retained
por: Lee, Jae-Hyun, et al.
Publicado: (2021) -
The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study
por: Ha, Seung-Ryong, et al.
Publicado: (2013)