Cargando…

Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs

BACKGROUND: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. OBJECTIVES: This study evaluated the influence of RR on PPV in mechanically ventilated he...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Dalhae, Son, Won-Gyun, Shin, Donghwi, Kim, Jiyoung, Lee, Inhyung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Veterinary Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9715388/
https://www.ncbi.nlm.nih.gov/pubmed/36038189
http://dx.doi.org/10.4142/jvs.22090
_version_ 1784842437769822208
author Kim, Dalhae
Son, Won-Gyun
Shin, Donghwi
Kim, Jiyoung
Lee, Inhyung
author_facet Kim, Dalhae
Son, Won-Gyun
Shin, Donghwi
Kim, Jiyoung
Lee, Inhyung
author_sort Kim, Dalhae
collection PubMed
description BACKGROUND: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. OBJECTIVES: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. METHODS: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. RESULTS: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). CONCLUSIONS: The PPV is a dynamic parameter that can predict a dog’s hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.
format Online
Article
Text
id pubmed-9715388
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Korean Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-97153882022-12-13 Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs Kim, Dalhae Son, Won-Gyun Shin, Donghwi Kim, Jiyoung Lee, Inhyung J Vet Sci Original Article BACKGROUND: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. OBJECTIVES: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. METHODS: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. RESULTS: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). CONCLUSIONS: The PPV is a dynamic parameter that can predict a dog’s hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation. The Korean Society of Veterinary Science 2022-07-22 /pmc/articles/PMC9715388/ /pubmed/36038189 http://dx.doi.org/10.4142/jvs.22090 Text en © 2022 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Dalhae
Son, Won-Gyun
Shin, Donghwi
Kim, Jiyoung
Lee, Inhyung
Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title_full Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title_fullStr Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title_full_unstemmed Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title_short Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
title_sort effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9715388/
https://www.ncbi.nlm.nih.gov/pubmed/36038189
http://dx.doi.org/10.4142/jvs.22090
work_keys_str_mv AT kimdalhae effectoftherespiratoryrateonthepulsepressurevariationinducedbyhemorrhageinanesthetizeddogs
AT sonwongyun effectoftherespiratoryrateonthepulsepressurevariationinducedbyhemorrhageinanesthetizeddogs
AT shindonghwi effectoftherespiratoryrateonthepulsepressurevariationinducedbyhemorrhageinanesthetizeddogs
AT kimjiyoung effectoftherespiratoryrateonthepulsepressurevariationinducedbyhemorrhageinanesthetizeddogs
AT leeinhyung effectoftherespiratoryrateonthepulsepressurevariationinducedbyhemorrhageinanesthetizeddogs