Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package

INTRODUCTION: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes. Directional bremsstrahlung splitting (DBS) is a technique that applies braking radiations in interactions in this software. This study aimed to eva...

Descripción completa

Detalles Bibliográficos
Autores principales: Babapour, Hamed, Semyari, Somayeh, Yadollahi, Masoumeh, Majdaeen, Mehrsa, Abedi-Firouzjah, Razzagh, Ataei, Gholamreza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9716629/
https://www.ncbi.nlm.nih.gov/pubmed/36466131
http://dx.doi.org/10.1177/11795972221138473
_version_ 1784842733454622720
author Babapour, Hamed
Semyari, Somayeh
Yadollahi, Masoumeh
Majdaeen, Mehrsa
Abedi-Firouzjah, Razzagh
Ataei, Gholamreza
author_facet Babapour, Hamed
Semyari, Somayeh
Yadollahi, Masoumeh
Majdaeen, Mehrsa
Abedi-Firouzjah, Razzagh
Ataei, Gholamreza
author_sort Babapour, Hamed
collection PubMed
description INTRODUCTION: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes. Directional bremsstrahlung splitting (DBS) is a technique that applies braking radiations in interactions in this software. This study aimed to evaluate the effect of this technique on the simulation time, uncertainty, particle number of phase-space data, and photon beam spectrum resulting from a medical linear accelerator (LINAC). MATERIALS AND METHODS: The gantry of the accelerator, including the materials and geometries of different parts, was simulated using the BEAMnrc code (a subset code in the EGSnrc package). The phase-space data were recorded in different parts of the LINAC. The DBS values (1, 10, 100, and 1000) were changed, and their effects were evaluated on the simulation parameters and output spectra. RESULTS: Increasing the DBS value from 1 to 1000 resulted in an increase in the simulation time from 1.778 to 11.310 hours, and increasing the number of particles in the phase-space plane (5 590 732-180 328 382). When the DBS had been picked up from 1 to 100, the simulation uncertainty decreased by about 1.29%. In addition, the DBS increment value from 100 to 1000 leads to an increase in uncertainty and simulation time of about 0.71% and 315%, respectively. CONCLUSION: Although using the DBS technique reduces the simulation time or uncertainty, increasing the DBS from a specific value, equal to 100 in our study, increases simulation uncertainties and times. Therefore, we propose considering a specific DBS value as we obtained for the Monte Carlo simulation of photon beams produced by linear accelerators.
format Online
Article
Text
id pubmed-9716629
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-97166292022-12-03 Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package Babapour, Hamed Semyari, Somayeh Yadollahi, Masoumeh Majdaeen, Mehrsa Abedi-Firouzjah, Razzagh Ataei, Gholamreza Biomed Eng Comput Biol Original Research INTRODUCTION: EGSnrc software package is one of the computational packages for Monte Carlo simulation in radiation therapy and has several subset codes. Directional bremsstrahlung splitting (DBS) is a technique that applies braking radiations in interactions in this software. This study aimed to evaluate the effect of this technique on the simulation time, uncertainty, particle number of phase-space data, and photon beam spectrum resulting from a medical linear accelerator (LINAC). MATERIALS AND METHODS: The gantry of the accelerator, including the materials and geometries of different parts, was simulated using the BEAMnrc code (a subset code in the EGSnrc package). The phase-space data were recorded in different parts of the LINAC. The DBS values (1, 10, 100, and 1000) were changed, and their effects were evaluated on the simulation parameters and output spectra. RESULTS: Increasing the DBS value from 1 to 1000 resulted in an increase in the simulation time from 1.778 to 11.310 hours, and increasing the number of particles in the phase-space plane (5 590 732-180 328 382). When the DBS had been picked up from 1 to 100, the simulation uncertainty decreased by about 1.29%. In addition, the DBS increment value from 100 to 1000 leads to an increase in uncertainty and simulation time of about 0.71% and 315%, respectively. CONCLUSION: Although using the DBS technique reduces the simulation time or uncertainty, increasing the DBS from a specific value, equal to 100 in our study, increases simulation uncertainties and times. Therefore, we propose considering a specific DBS value as we obtained for the Monte Carlo simulation of photon beams produced by linear accelerators. SAGE Publications 2022-11-29 /pmc/articles/PMC9716629/ /pubmed/36466131 http://dx.doi.org/10.1177/11795972221138473 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page(https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Babapour, Hamed
Semyari, Somayeh
Yadollahi, Masoumeh
Majdaeen, Mehrsa
Abedi-Firouzjah, Razzagh
Ataei, Gholamreza
Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title_full Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title_fullStr Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title_full_unstemmed Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title_short Assessing the Effect of Directional Bremsstrahlung Splitting on the Output Spectra and Parameters Using BEAMnrc Monte Carlo Simulation Package
title_sort assessing the effect of directional bremsstrahlung splitting on the output spectra and parameters using beamnrc monte carlo simulation package
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9716629/
https://www.ncbi.nlm.nih.gov/pubmed/36466131
http://dx.doi.org/10.1177/11795972221138473
work_keys_str_mv AT babapourhamed assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage
AT semyarisomayeh assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage
AT yadollahimasoumeh assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage
AT majdaeenmehrsa assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage
AT abedifirouzjahrazzagh assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage
AT ataeigholamreza assessingtheeffectofdirectionalbremsstrahlungsplittingontheoutputspectraandparametersusingbeamnrcmontecarlosimulationpackage