Cargando…
Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies
Staphylococcus aureus (S. aureus) and Pseudomonas aeruginosa (P. aeruginosa) are major pathogens frequently detected in food and beverage poisoning, and persistent infections. Therefore, the development of a rapid method that can detect these pathogens before serious multiplication is required. In t...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717348/ https://www.ncbi.nlm.nih.gov/pubmed/36545616 http://dx.doi.org/10.1039/d2ra05694a |
_version_ | 1784842884661379072 |
---|---|
author | Kim, Joo-Kyung Yun, Hanool Yeom, Chang-Hun Kim, Eun-Jung Kim, Wooseong Lee, Chang-Soo Kim, Byung-Gee Jeong, Hee-Jin |
author_facet | Kim, Joo-Kyung Yun, Hanool Yeom, Chang-Hun Kim, Eun-Jung Kim, Wooseong Lee, Chang-Soo Kim, Byung-Gee Jeong, Hee-Jin |
author_sort | Kim, Joo-Kyung |
collection | PubMed |
description | Staphylococcus aureus (S. aureus) and Pseudomonas aeruginosa (P. aeruginosa) are major pathogens frequently detected in food and beverage poisoning, and persistent infections. Therefore, the development of a rapid method that can detect these pathogens before serious multiplication is required. In this study, we established a flow cytometry (FCM)-based detection method that allows rapid acquisition of cell populations in fluid samples by using a fluorescent antibody against S. aureus or P. aeruginosa. Using this method, we detected these pathogens with a 10(3) to 10(5) CFU order of limit of detection value within 1 hour. The FCM-based method for the detection of S. aureus and P. aeruginosa offers the possibility of high-throughput analysis of pathogens in food, environmental, and clinical sources. |
format | Online Article Text |
id | pubmed-9717348 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-97173482022-12-20 Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies Kim, Joo-Kyung Yun, Hanool Yeom, Chang-Hun Kim, Eun-Jung Kim, Wooseong Lee, Chang-Soo Kim, Byung-Gee Jeong, Hee-Jin RSC Adv Chemistry Staphylococcus aureus (S. aureus) and Pseudomonas aeruginosa (P. aeruginosa) are major pathogens frequently detected in food and beverage poisoning, and persistent infections. Therefore, the development of a rapid method that can detect these pathogens before serious multiplication is required. In this study, we established a flow cytometry (FCM)-based detection method that allows rapid acquisition of cell populations in fluid samples by using a fluorescent antibody against S. aureus or P. aeruginosa. Using this method, we detected these pathogens with a 10(3) to 10(5) CFU order of limit of detection value within 1 hour. The FCM-based method for the detection of S. aureus and P. aeruginosa offers the possibility of high-throughput analysis of pathogens in food, environmental, and clinical sources. The Royal Society of Chemistry 2022-12-02 /pmc/articles/PMC9717348/ /pubmed/36545616 http://dx.doi.org/10.1039/d2ra05694a Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Kim, Joo-Kyung Yun, Hanool Yeom, Chang-Hun Kim, Eun-Jung Kim, Wooseong Lee, Chang-Soo Kim, Byung-Gee Jeong, Hee-Jin Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title | Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title_full | Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title_fullStr | Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title_full_unstemmed | Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title_short | Flow cytometry-based rapid detection of Staphylococcus aureus and Pseudomonas aeruginosa using fluorescent antibodies |
title_sort | flow cytometry-based rapid detection of staphylococcus aureus and pseudomonas aeruginosa using fluorescent antibodies |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717348/ https://www.ncbi.nlm.nih.gov/pubmed/36545616 http://dx.doi.org/10.1039/d2ra05694a |
work_keys_str_mv | AT kimjookyung flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT yunhanool flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT yeomchanghun flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT kimeunjung flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT kimwooseong flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT leechangsoo flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT kimbyunggee flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies AT jeongheejin flowcytometrybasedrapiddetectionofstaphylococcusaureusandpseudomonasaeruginosausingfluorescentantibodies |