Cargando…

Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy

OBJECTIVES: Complications after CT-guided lung biopsy is a burden both for the individual patient and for the overall healthcare. Pneumothorax is the most common complication. This study determined the association between lung function tests and pneumothorax and chest drainage following CT-guided lu...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruud, Espen Asak, Heck, Sigurd, Stavem, Knut, Søyseth, Vidar, Geitung, Jon Terje, Ashraf, Haseem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717539/
https://www.ncbi.nlm.nih.gov/pubmed/36457053
http://dx.doi.org/10.1186/s13104-022-06234-6
_version_ 1784842920909602816
author Ruud, Espen Asak
Heck, Sigurd
Stavem, Knut
Søyseth, Vidar
Geitung, Jon Terje
Ashraf, Haseem
author_facet Ruud, Espen Asak
Heck, Sigurd
Stavem, Knut
Søyseth, Vidar
Geitung, Jon Terje
Ashraf, Haseem
author_sort Ruud, Espen Asak
collection PubMed
description OBJECTIVES: Complications after CT-guided lung biopsy is a burden both for the individual patient and for the overall healthcare. Pneumothorax is the most common complication. This study determined the association between lung function tests and pneumothorax and chest drainage following CT-guided lung biopsy in consecutive patients in a large university hospital. RESULTS: We prospectively registered 875 biopsy procedures from 786 patients in one institution from January 27th 2012 to March 1st 2017 and recorded complications including pneumothorax with or without chest drainage. Lung function data from 637 patients undergoing 710 of the procedures were available. The association of lung function measures with pneumothorax with or without chest drainage was assessed using multivariable logistic regression analyses. Diffusion capacity for carbon monoxide (DLCO) below 4.70 mmol/min/kPa was associated with increased occurrence of pneumothorax and chest drainage after CT guided lung biopsy. We found no association between FEV(1), RV and occurrence of pneumothorax and chest drainage. We found low DLCO to be a risk factor of pneumothorax and chest drainage after CT-guided lung biopsy. This should be taken into account in planning and performing the procedure.
format Online
Article
Text
id pubmed-9717539
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-97175392022-12-03 Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy Ruud, Espen Asak Heck, Sigurd Stavem, Knut Søyseth, Vidar Geitung, Jon Terje Ashraf, Haseem BMC Res Notes Research Note OBJECTIVES: Complications after CT-guided lung biopsy is a burden both for the individual patient and for the overall healthcare. Pneumothorax is the most common complication. This study determined the association between lung function tests and pneumothorax and chest drainage following CT-guided lung biopsy in consecutive patients in a large university hospital. RESULTS: We prospectively registered 875 biopsy procedures from 786 patients in one institution from January 27th 2012 to March 1st 2017 and recorded complications including pneumothorax with or without chest drainage. Lung function data from 637 patients undergoing 710 of the procedures were available. The association of lung function measures with pneumothorax with or without chest drainage was assessed using multivariable logistic regression analyses. Diffusion capacity for carbon monoxide (DLCO) below 4.70 mmol/min/kPa was associated with increased occurrence of pneumothorax and chest drainage after CT guided lung biopsy. We found no association between FEV(1), RV and occurrence of pneumothorax and chest drainage. We found low DLCO to be a risk factor of pneumothorax and chest drainage after CT-guided lung biopsy. This should be taken into account in planning and performing the procedure. BioMed Central 2022-12-01 /pmc/articles/PMC9717539/ /pubmed/36457053 http://dx.doi.org/10.1186/s13104-022-06234-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Note
Ruud, Espen Asak
Heck, Sigurd
Stavem, Knut
Søyseth, Vidar
Geitung, Jon Terje
Ashraf, Haseem
Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title_full Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title_fullStr Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title_full_unstemmed Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title_short Low diffusion capacity of the lung predicts pneumothorax and chest drainage after CT-guided lung biopsy
title_sort low diffusion capacity of the lung predicts pneumothorax and chest drainage after ct-guided lung biopsy
topic Research Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717539/
https://www.ncbi.nlm.nih.gov/pubmed/36457053
http://dx.doi.org/10.1186/s13104-022-06234-6
work_keys_str_mv AT ruudespenasak lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy
AT hecksigurd lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy
AT stavemknut lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy
AT søysethvidar lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy
AT geitungjonterje lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy
AT ashrafhaseem lowdiffusioncapacityofthelungpredictspneumothoraxandchestdrainageafterctguidedlungbiopsy