Cargando…
Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae)
The utilization of hybrid-constructed wetland systems has recently expanded due to more rigorous municipal wastewater discharge and also complex wastewaters treated in hybrid-constructed wetlands (HCWs). A lab-scale two-stage experimental setup of vertical flow followed by horizontal flow hybrid-con...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717559/ https://www.ncbi.nlm.nih.gov/pubmed/36504546 http://dx.doi.org/10.1007/s11270-022-05984-0 |
_version_ | 1784842925390168064 |
---|---|
author | Singh, Krishna Kumar Vaishya, Rakesh Chandra |
author_facet | Singh, Krishna Kumar Vaishya, Rakesh Chandra |
author_sort | Singh, Krishna Kumar |
collection | PubMed |
description | The utilization of hybrid-constructed wetland systems has recently expanded due to more rigorous municipal wastewater discharge and also complex wastewaters treated in hybrid-constructed wetlands (HCWs). A lab-scale two-stage experimental setup of vertical flow followed by horizontal flow hybrid-constructed wetland (VFHCW-HFHCW) configuration was built. First-stage vertical flow hybrid-constructed wetland reactor with the surface area was 1963.49 cm(2) and second-stage horizontal flow hybrid-constructed wetland reactor with the surface area was 2025 cm(2). The HCW unit was planted with two type plants: Calibanus hookeri and Canna indica (Cannaceae). Influent Municipal wastewater flow rate 112.32 l/day, hydraulic loading rate (HLR) 0.55 m/day, and hydraulic retention time of 1 day. The efficiency was evaluated in municipal wastewater quality improvement and physico-chemical analysis in our laboratory. The removal rate after the second-stage horizontal flow of BOD(3) at 27 °C, COD, TSS, TP, NH(3)-N, and NO(3)-N reached 92.75%, 89.90%, 85.45%, 88.83%, 99.09%, and 96.05%, respectively. The results shown after both stage hybrid-constructed wetland VFHCW-HFHCW, treated effluent of Municipal wastewater produced high-quality effluent which may be reused in gardening, agriculture, and flushing in toilet purpose according to Bureau of Indian Standards (BIS) code for practices. However, in the future, hybrid-constructed wetlands could be standards design criteria developing and enhancing the performance standards and economic meets both to make more popular technology of the hybrid-constructed wetland (HCW). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11270-022-05984-0. |
format | Online Article Text |
id | pubmed-9717559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-97175592022-12-05 Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) Singh, Krishna Kumar Vaishya, Rakesh Chandra Water Air Soil Pollut Article The utilization of hybrid-constructed wetland systems has recently expanded due to more rigorous municipal wastewater discharge and also complex wastewaters treated in hybrid-constructed wetlands (HCWs). A lab-scale two-stage experimental setup of vertical flow followed by horizontal flow hybrid-constructed wetland (VFHCW-HFHCW) configuration was built. First-stage vertical flow hybrid-constructed wetland reactor with the surface area was 1963.49 cm(2) and second-stage horizontal flow hybrid-constructed wetland reactor with the surface area was 2025 cm(2). The HCW unit was planted with two type plants: Calibanus hookeri and Canna indica (Cannaceae). Influent Municipal wastewater flow rate 112.32 l/day, hydraulic loading rate (HLR) 0.55 m/day, and hydraulic retention time of 1 day. The efficiency was evaluated in municipal wastewater quality improvement and physico-chemical analysis in our laboratory. The removal rate after the second-stage horizontal flow of BOD(3) at 27 °C, COD, TSS, TP, NH(3)-N, and NO(3)-N reached 92.75%, 89.90%, 85.45%, 88.83%, 99.09%, and 96.05%, respectively. The results shown after both stage hybrid-constructed wetland VFHCW-HFHCW, treated effluent of Municipal wastewater produced high-quality effluent which may be reused in gardening, agriculture, and flushing in toilet purpose according to Bureau of Indian Standards (BIS) code for practices. However, in the future, hybrid-constructed wetlands could be standards design criteria developing and enhancing the performance standards and economic meets both to make more popular technology of the hybrid-constructed wetland (HCW). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11270-022-05984-0. Springer International Publishing 2022-12-01 2022 /pmc/articles/PMC9717559/ /pubmed/36504546 http://dx.doi.org/10.1007/s11270-022-05984-0 Text en © The Author(s), under exclusive licence to Springer Nature Switzerland AG 2022, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Article Singh, Krishna Kumar Vaishya, Rakesh Chandra Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title | Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title_full | Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title_fullStr | Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title_full_unstemmed | Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title_short | Municipal Wastewater Treatment uses Vertical Flow Followed by Horizontal Flow in a Two-Stage Hybrid-Constructed Wetland Planted with Calibanus hookeri and Canna indica (Cannaceae) |
title_sort | municipal wastewater treatment uses vertical flow followed by horizontal flow in a two-stage hybrid-constructed wetland planted with calibanus hookeri and canna indica (cannaceae) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9717559/ https://www.ncbi.nlm.nih.gov/pubmed/36504546 http://dx.doi.org/10.1007/s11270-022-05984-0 |
work_keys_str_mv | AT singhkrishnakumar municipalwastewatertreatmentusesverticalflowfollowedbyhorizontalflowinatwostagehybridconstructedwetlandplantedwithcalibanushookeriandcannaindicacannaceae AT vaishyarakeshchandra municipalwastewatertreatmentusesverticalflowfollowedbyhorizontalflowinatwostagehybridconstructedwetlandplantedwithcalibanushookeriandcannaindicacannaceae |