Cargando…
Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI
OBJECTIVES: High-resolution post-contrast T1-weighted imaging is a workhorse sequence in the evaluation of neurological disorders. The T1-MPRAGE sequence has been widely adopted for the visualization of enhancing pathology in the brain. However, this three-dimensional (3D) acquisition is lengthy and...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9718459/ https://www.ncbi.nlm.nih.gov/pubmed/36460923 http://dx.doi.org/10.1007/s00330-022-09265-6 |
_version_ | 1784843095070736384 |
---|---|
author | Goncalves Filho, Augusto Lio M. Awan, Komal Manzoor Conklin, John Ngamsombat, Chanon Cauley, Stephen F. Setsompop, Kawin Liu, Wei Splitthoff, Daniel N. Lo, Wei-Ching Kirsch, John E. Schaefer, Pamela W. Rapalino, Otto Huang, Susie Y. |
author_facet | Goncalves Filho, Augusto Lio M. Awan, Komal Manzoor Conklin, John Ngamsombat, Chanon Cauley, Stephen F. Setsompop, Kawin Liu, Wei Splitthoff, Daniel N. Lo, Wei-Ching Kirsch, John E. Schaefer, Pamela W. Rapalino, Otto Huang, Susie Y. |
author_sort | Goncalves Filho, Augusto Lio M. |
collection | PubMed |
description | OBJECTIVES: High-resolution post-contrast T1-weighted imaging is a workhorse sequence in the evaluation of neurological disorders. The T1-MPRAGE sequence has been widely adopted for the visualization of enhancing pathology in the brain. However, this three-dimensional (3D) acquisition is lengthy and prone to motion artifact, which often compromises diagnostic quality. The goal of this study was to compare a highly accelerated wave-controlled aliasing in parallel imaging (CAIPI) post-contrast 3D T1-MPRAGE sequence (Wave-T1-MPRAGE) with the standard 3D T1-MPRAGE sequence for visualizing enhancing lesions in brain imaging at 3 T. METHODS: This study included 80 patients undergoing contrast-enhanced brain MRI. The participants were scanned with a standard post-contrast T1-MPRAGE sequence (acceleration factor [R] = 2 using GRAPPA parallel imaging technique, acquisition time [TA] = 5 min 18 s) and a prototype post-contrast Wave-T1-MPRAGE sequence (R = 4, TA = 2 min 32 s). Two neuroradiologists performed a head-to-head evaluation of both sequences and rated the visualization of enhancement, sharpness, noise, motion artifacts, and overall diagnostic quality. A 15% noninferiority margin was used to test whether post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE. Inter-rater and intra-rater agreement were calculated. Quantitative assessment of CNR/SNR was performed. RESULTS: Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE for delineating enhancing lesions with unanimous agreement in all cases between raters. Wave-T1-MPRAGE was noninferior in the perception of noise (p < 0.001), motion artifact (p < 0.001), and overall diagnostic quality (p < 0.001). CONCLUSION: High-accelerated post-contrast Wave-T1-MPRAGE enabled a two-fold reduction in acquisition time compared to the standard sequence with comparable performance for visualization of enhancing pathology and equivalent perception of noise, motion artifacts and overall diagnostic quality without loss of clinically important information. KEY POINTS: • Post-contrast wave-controlled aliasing in parallel imaging (CAIPI) T1-MPRAGE accelerated the acquisition of three-dimensional (3D) high-resolution post-contrast images by more than two-fold. • Post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE with unanimous agreement between reviewers (100% in 80 cases) for the visualization of intracranial enhancing lesions. • Wave-T1-MPRAGE was equivalent to the standard sequence in the perception of noise in 94% (75 of 80) of cases and was preferred in 16% (13 of 80) of cases for decreased motion artifact. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09265-6. |
format | Online Article Text |
id | pubmed-9718459 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-97184592022-12-05 Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI Goncalves Filho, Augusto Lio M. Awan, Komal Manzoor Conklin, John Ngamsombat, Chanon Cauley, Stephen F. Setsompop, Kawin Liu, Wei Splitthoff, Daniel N. Lo, Wei-Ching Kirsch, John E. Schaefer, Pamela W. Rapalino, Otto Huang, Susie Y. Eur Radiol Neuro OBJECTIVES: High-resolution post-contrast T1-weighted imaging is a workhorse sequence in the evaluation of neurological disorders. The T1-MPRAGE sequence has been widely adopted for the visualization of enhancing pathology in the brain. However, this three-dimensional (3D) acquisition is lengthy and prone to motion artifact, which often compromises diagnostic quality. The goal of this study was to compare a highly accelerated wave-controlled aliasing in parallel imaging (CAIPI) post-contrast 3D T1-MPRAGE sequence (Wave-T1-MPRAGE) with the standard 3D T1-MPRAGE sequence for visualizing enhancing lesions in brain imaging at 3 T. METHODS: This study included 80 patients undergoing contrast-enhanced brain MRI. The participants were scanned with a standard post-contrast T1-MPRAGE sequence (acceleration factor [R] = 2 using GRAPPA parallel imaging technique, acquisition time [TA] = 5 min 18 s) and a prototype post-contrast Wave-T1-MPRAGE sequence (R = 4, TA = 2 min 32 s). Two neuroradiologists performed a head-to-head evaluation of both sequences and rated the visualization of enhancement, sharpness, noise, motion artifacts, and overall diagnostic quality. A 15% noninferiority margin was used to test whether post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE. Inter-rater and intra-rater agreement were calculated. Quantitative assessment of CNR/SNR was performed. RESULTS: Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE for delineating enhancing lesions with unanimous agreement in all cases between raters. Wave-T1-MPRAGE was noninferior in the perception of noise (p < 0.001), motion artifact (p < 0.001), and overall diagnostic quality (p < 0.001). CONCLUSION: High-accelerated post-contrast Wave-T1-MPRAGE enabled a two-fold reduction in acquisition time compared to the standard sequence with comparable performance for visualization of enhancing pathology and equivalent perception of noise, motion artifacts and overall diagnostic quality without loss of clinically important information. KEY POINTS: • Post-contrast wave-controlled aliasing in parallel imaging (CAIPI) T1-MPRAGE accelerated the acquisition of three-dimensional (3D) high-resolution post-contrast images by more than two-fold. • Post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE with unanimous agreement between reviewers (100% in 80 cases) for the visualization of intracranial enhancing lesions. • Wave-T1-MPRAGE was equivalent to the standard sequence in the perception of noise in 94% (75 of 80) of cases and was preferred in 16% (13 of 80) of cases for decreased motion artifact. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00330-022-09265-6. Springer Berlin Heidelberg 2022-12-02 2023 /pmc/articles/PMC9718459/ /pubmed/36460923 http://dx.doi.org/10.1007/s00330-022-09265-6 Text en © The Author(s), under exclusive licence to European Society of Radiology 2022, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Neuro Goncalves Filho, Augusto Lio M. Awan, Komal Manzoor Conklin, John Ngamsombat, Chanon Cauley, Stephen F. Setsompop, Kawin Liu, Wei Splitthoff, Daniel N. Lo, Wei-Ching Kirsch, John E. Schaefer, Pamela W. Rapalino, Otto Huang, Susie Y. Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title | Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title_full | Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title_fullStr | Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title_full_unstemmed | Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title_short | Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI |
title_sort | validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (caipi) 3d-t1 mprage compared to standard 3d-t1 mprage for detection of intracranial enhancing lesions on 3-t mri |
topic | Neuro |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9718459/ https://www.ncbi.nlm.nih.gov/pubmed/36460923 http://dx.doi.org/10.1007/s00330-022-09265-6 |
work_keys_str_mv | AT goncalvesfilhoaugustoliom validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT awankomalmanzoor validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT conklinjohn validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT ngamsombatchanon validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT cauleystephenf validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT setsompopkawin validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT liuwei validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT splitthoffdanieln validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT loweiching validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT kirschjohne validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT schaeferpamelaw validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT rapalinootto validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri AT huangsusiey validationofahighlyacceleratedpostcontrastwavecontrolledaliasinginparallelimagingcaipi3dt1mpragecomparedtostandard3dt1mpragefordetectionofintracranialenhancinglesionson3tmri |